Login:
Votes - , Average rating: ( )

User manual AMX, model Dimmer Enclosures w/Breakers RDA-ENC12B

Manafacture: AMX
File size: 200.7 kb
File name:

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


(7.48 kg) • RDA-ENC12B: 17.5 lbs. (7.94 kg) Dimensions between center lines (from FIG. 2): RDA-ENC6B: • A to B = 16.0" (406.4 mm) • B to C = 22.88" (581.2 mm) RDA-ENC12B: • A to B = 16.0" (406.4 mm) • B to C = 22.88" (581.2 mm) Radia enclosures must be mounted on a vertical surface with a minimum of 12" (304.8 mm) clearance above and below the enclosure. Configuration for right and left mounting brackets for all Radia enclosures. à .A to B Top slot Maximum mounting screw size: #12 Bottom slot B to C _ jTlL I FIG. 2 Bracket configuration Specifications Maximum input wire #1/0 AWG (50mm2) Maximum line input is 120 A (per terminal) Torque input wire to 44 in-lbs. (5.0 N/m) Wire stripping length: 0.67 inches (17 mm) Input 1 feeds channels 1, 4, 7, and 10 Input 2a feeds channels 5 and 11 Input 2b feeds channels 2 and 8 Input 3 feeds channels 3, 6, 9, and 12 Breakers are UL 489 listed 10,000 AIC, 100% Switching Duty, Hydraulic-Magnetic The following section cross references the UL ID module numbers and AMX Lighting module IDs. The modules identified are the only ones that can be used in the RDA-ENC6B and RDA-ENC12B enclosures. UL Number Cross Reference to AMX Lighting ID UL ID AMX ID UL ID AMX ID UL ID AMX ID 28-10100 RDC-DC/120 28-10200 RDM-INC 28-10300 RDM-MR60 28-10110 RDC-DC/240 28-10210 RDM-2INC 28-10310 RDM-MDM 28-10120 RDC-DC/277 28-10220 RDM-INC50 28-10340 RDA-CHK 28-10130 RDC-PDC/120 28-10230 RDM-ZC, RDM-2ZC 28-10350 RDM-FDB RDM-2FDB RDM-3FDB RDM-HFDB 28-10133 RDC-PDC/240 28-10240 RDM-ZC50 28-10360 RDM-DPSM UL Number Cross Reference to AMX Lighting ID (Cont.) UL ID AMX ID UL ID AMX ID UL ID AMX ID 28-10140 RDD-DM6/120 28-10260 RDM-SWM, RDM-2SWM, RDM-3SWM 28-10370 RDM-DC, RDM-2DC, RDM-3DC RDM-HDC 28-10150 RDD-DM6/240 28-10270 RDM-HSW, RDM-2HSW, RDM-3HSW 28-10160 RDD-DM6/277 28-10170 RDA-PSM/120 Lighting Application Drawings LINE INPUT B A □1 B □1 A B A S A B SINGLE PHASE. 120VAC. 2W + G CONNECTED PHASE CONTROLS ALL DIMMERS 1-6 SINGLE PHASE. 120/208VAC. 3W + G B c □1 A B mm C A B C A PHASE C, LINE INPUT - PHASE B, LINE INPUT ~ PHASE A, LINE INPUT — Note: > LINE INPUTS: 120 A MAX PER TERMINAL Use 75° C copper conductors only. ue terminals to 44 in-lbs. , yTorq THREE PHASE. 12Q/20BVAC. 4W PHASE A -PHASE 0 -PHASE C - CONTROLS DIMMERS 1 AND 4 CONTROLS DIMMERS 2 AND 5 CONTROLS DIMMERS 3 AND 6 FIG. 3 ENC6B and ENC12B Power Distribution CIRCUIT BREAKERS LINE INPUTS N 1 2A2B 3 1 2 3 4 5 6 LINE OUTPUTS CONTROL CIRCUITRY POWER NEUTRAL , LINE 1 ^ LINE 2A ; LINE 2B ' LINE 3 ; WHITE BLACK FIG. 4 ENC6B and ENC12B Input Terminal Block Wiring CIRCUIT BREAKERS (ENC12B ONLY) 11 „ 10. WHITE BLACK LINE OUTPUTS (ENC12B ONLY) NEUTRAL LINE 1 LINE 2A LINE 2B LINE 3 CONTROL CIRCUITRY POWER (ENC12B ONLY) For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s). 10/08 ©2008 AMX. All ...

Other models in this manual:
Other Home Accessories - Dimmer Enclosures w/Breakers RDA-ENC6B (200.7 kb)
Other Home Accessories - ENC12B (200.7 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category