|
manual abstract
If this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance. The plate has a series of holes to allow for adjustment. Remove the two screws on either side of the exhaust collar inside the firebox. Install the plate in the desired set of holes, then replace the screws. It is recommend to secure in the third set of holes which causes the greatest amount of restriction for vent length between 15 and 30 feet. TOP OF FIREBOX RESTRICTOR PLATE FLUE COLLAR MINIMUM FRAMING CLEARANCES WARNING THE STANDOFFS HAVE BEEN SHIPPED FLAT. BEFORE FRAMING ENSURE THE STANDOFFS ARE BENT UP AND SCREWED INTO PLACE. ATTENTION ATENCION LAS TRABAS PERMANECEN PLANAS DURANTE EL ENVIO. ANTES DE LA INSTALACION, VERIFIQUE QUE LAS TRABAS SE PLIEGUEN HACIA ARRIBA Y SE ATORNILLEN CORRECTAMENTE. LES ESPACEURS SONT EMBALLES A PLAT. AVANT DE CONSTRUIRE L'OSSATURE, ASSUREZ-VOUS QUE LESESPACEURS SONT PLIES ET FIXES EN PLACE A L'AIDE DE VIS. FIGURE 29 FIGURE 28 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4’s and frame to local building codes. NOTE: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity. For convenience, the stand-offs have been shipped flat. Before framing, ensure the stand-offs are opened and screwed in place. It is not necessary to install a hearth extension, but the fireplace should be raised to be flush with either the hearth or the finished floor. When roughing in the fireplace, raise the fireplace to accommodate for the thickness of the finished floor materials, i.e. tile, carpeting, hard wood. Objects placed in front of the fireplace should be kept a minimum of 48” away from the front face. W415-0665 / B / 02.11.08 44" 621/8"29"1" MIN 1" MIN 22 1/2" FIGURE 30a-b 29" 10" ! WARNING MIN Do not build into this area - it must be left clear to provide adequate clearance for the vent in this 14” wide area centered along W415-0665 / B / 02.11.08 29” 72” MINIMUM ENCLOSURE HEIGHT the front of the fireplace. No combustibles are allowed. 22 1/2” 3 1/2” MAXIMUM 58 1/4” 14” MINIMUM 1 1/2” MAXIMUM 8 7/8” 2” GAS INLET FIGURE 31 MINIMUM ENCLOSURE CLEARANCES Minimum clearance to combustible construction from fi replace and vent surfaces: Combustible framing: -0“ to stand-offs Non-combustible fi replace fi nishing: -4“ from the sides of fireplace opening -22 3/8 “ to the top of fireplace opening Combustible fi replace fi nishing: -0“ to rear and sides -2” all around the vent pipe -22 1/2 “ recessed depth -72“ from bottom of unit to enclosure top -72” from bottom of unit to ceiling MINIMUM ENCLOSURE CLEARANCES Minimum clearance to combustible construction from fi replace and vent surfaces: Combustible framing: -0“ to stand-offs Non-combustible fi replace fi nishing: -4“ from the sides of fireplace opening -22 3/8 “ to the top of fireplace opening Combustible fi replace fi nishing: -0“ to rear and sides -2” all around the vent pipe -22 1/2 “ recessed depth -72“ from bottom of unit to enclosure top -72” from bottom of unit to ceiling HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required. Use firestop spacer W010-1799 (supplied). VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles is required except for clearances in fireplace enclosures. Use firestop spacer W500-0096 (not supplied). FIGURE 32 W415-0665 / B / 02.11.08 Facing and/or fi nishing material must never overhang into the fi replace opening. Do not distort or force the frame kit components. When using a rough fi nish material (i.e.; stone), maintain a .” - .” border from the framing components. ! WARNING 18 W415-0665 / B / 02.11.08 2” 2” 72” 26” 8” 56” MINIMUM PLUS RISE* COMBUSTIBLE NON-COMBUSTIBLE BRICK 1” COMBUSTIBLE NONCOMBUSTIBLE 0” IF NONCOMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE 12 1/4” INSULATION SLEEVE 2” IMPORTANT: The requires a minimum inside enclosure height of 72”. For temperature requirements, the enclosure space around and above the fi replace must be left unobstructed. * See venting section 0 3 4 7 8 9 11 13 1 2 5 6 7 10 12 HEIGHT MA NTEL MANTEL DEPTH 14 8 FIGURES 33 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. FIGURE 34 8” MANTEL 2” 4” 6” 14” 12” 10” 8” TOP OF FIREPLACE OPENING TOP OF FIREPLACE NON-COMBUSTIBLE Do NOT use the fi replace if any part has been under water. Call a qualifi ed service technician IMMEDIATELY to...
Other models in this manual:Other Home Accessories - GD82NT-PA (4.81 mb)