Manafacture: Napoleon Fireplaces
File size: 4.99 mb
File name:
|
manual abstract
Screen must be closed when appliance is in operation. GENERAL INFORMATION CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/ or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people---pregnant women, persons with heart or lung disease, anaemia, those under the influence of alcohol, those at high altitudes-- are more affected by carbon monoxide than others. for example: in Massachusetts State: • The appliance off valve must be a “T” handle gas cock. • The flexible connector must not be longer than 36 inches. • The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product. • WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts. • Un-vented room heater shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00 through 7.00. • Sellers of un-vented propane or natural gas-fired space/room heaters shall provide to each purchaser a copy of 527 CMR 30.00 upon the sale of the unit from nstallation_manuals/mass_requirements.pdf • A carbon monoxide detector is required in all rooms containing gas fired appliances. Always shut off the appliance, gas to the appliance and allow the appliance to cool before servicing it. Visually inspect the appliance for carbon buildup. Using a small whisk or brush, brush off the excess carbon and vacuum up or sweep into the garbage. Check the appliance for broken logs and corrosion of the main burner base. MAINTENANCE & CLEANING GENERAL INSTRUCTIONS FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUAL- ITY! Maximum input is 40,000 BTU/hr for natural gas and propane. Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane. No external electricity (110 volts or 24 volts) is required for the gas system operation. This heater is equipped with a pilot light safety system referred to as an OXYGEN DEPLETION SENSOR and is designed to turn off the heater if not enough fresh air is available. Use only accessories designed for and listed with your specific fireplace. Not designed for use with a glass door. Screen must be closed when appliance is in operation. GENERAL INFORMATION CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/ or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people---pregnant women, persons with heart or lung disease, anaemia, those under the influence of alcohol, those at high altitudes-- are more affected by carbon monoxide than others. W415-0530 / 12.14.05 5 2 1. With the 2 andirons laying face down, secure the grate overtop using 2x .-20 bolts (supplied in the manual baggie). 2. Install the grate/andiron assembly to the burner base using 4x .” self tapping screws (supplied in the manual baggie). ANDIRON & GRATE ASSEMBLY Use only accesso- ries designed for and listed with your specific log set. AIR SHUTTER TESGOLRETTUHSRIALEUFGNPL81LFVG9/23" 5/61" 42LFVGThe air shutter settings are factory set for most installations. However, adjustment may be required depending on fuel type, vent performance and altitude. Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established. MINIMUM FIREPLACE SIZE Each gas log set must be installed into a fireplace cavity with a minimum size. Refer to the table below to determine the appropriate minimum fireplace size. 1 This appliance must be isolated from the gas supply piping system by closing the individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than . psi (3.5 kPa) 1. Centre the appliance in the fireplace opening, making sure the appliance has enough room behind it for the gas line to run behind the log set under the log support. 2. Route the gas line and sizing using piping .” diameter or greater to allow the full volume of gas to the appliance. The routing of the gas line has to be done to local and / or national codes. 3. When rigid pipe is used an ANSI approved manual shut off and a union must be installed upstream within the fireplace cavity. 4. To ensure the appliance operates reliably install a s...
Other models in this manual:Other Home Accessories - GLVF18N (4.99 mb)
Other Home Accessories - GLVF18P (4.99 mb)
Other Home Accessories - GLVF24P (4.99 mb)
Other Home Accessories - GLVF30N (4.99 mb)