Login:
Votes - 3, Average rating: 4 ( )

User manual Napoleon Fireplaces, model GD82PT-T

Manafacture: Napoleon Fireplaces
File size: 2.97 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


7. Apply a heavy bead of waterproof caulking 2 inches above the fl ashing. Slide the storm collar around the air terminal connector and down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the collar is achieved. 8. Continue adding rigid venting sections, sealing and securing as above. Attach a 4” collapsed telescopic pipe to the last section of rigid piping. Secure with screws and seal. Repeat using a 7” telescopic pipe. 9. Run a bead of high temperature sealant around the outside of the 4” collar on the fi replace. Pull the adjustable pipe a minimum of 2” onto the collar. Secure with 3 screws. Repeat with the 7” telescopic pipe. 10. In the attic, slide the vent pipe collar down to cover up the open end of the shield and tighten. This will prevent any materials, such as insulation, from fi lling up the 1” air space around the pipe. GAS INSTALLATION Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more traditional appearance. The plate has a series of holes to allow for adjustment. Remove the two screws on either side of the exhaust collar inside the fi rebox. Install the plate in the desired set of holes, then replace the screws. It is recommend to secure in the third set of holes which causes the greatest amount of restriction for vent length between 15 and 30 feet. RESTRICTING VERTICAL VENTS FIGURE 25 FIGURE 26 FIGURE 27 2" 8 7/8" MOBILE HOME INSTALLATION This appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance. This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equipped with two 1/4” diameter holes located in the fron left and right corners of the base. For mobile home installations, the fi replace must be fastened in place. Use #10 hex head screws, inserted through the holes in the base to secure. Always turn off the pilot and the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the fi replace, ensure that the logs are positioned correctly. This appliance is certifi ed to be installed in an aftermarket permanently located manufactured (mobile) home, where not prohibited by local codes. 14 W415-0583 / B / 05.23.07 WARNING Facing and/or fi nishing material must never overhang into the fi replace opening. Do not distort or force the frame kit components. When using a rough fi nish material (i.e.; stone), maintain a .” - .” border from the framing components. NON-COMBUSTIBLE FINISHING MATERIAL 59 3/8" 21 3/4" 32" 4" 4" STUD 2" FIRESTOP SPACER COMBUSTIBLE MATERIAL 2" NON-COMBUSTIBLE 72" 24" SPACER STAND OFF 62 1/8" 29" 44" 1" MIN 1" MIN 29" 22 1/2" 10" MIN 58 1/2" 72" 29" 22 1/2" FIGURE 31 FRAMING CLEARANCE TO COMBUSTIBLES MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: Fireplace framing - 0” to stand-offs (top, rear & sides) Fireplace fi nishing - 4” to sides of fi replace opening. - 21 3/4” to top of fi replace opening. FIGURE 28 FIGURE 29 FIGURE 30 It is best to frame your fi replace after it is positioned and the vent system is installed. Use 2x4’s and frame to local building codes. Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fi replace body, it is recommended that the walls of the fi replace enclosure be “fi nished” (ie: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity. For convenience, the stand-offs have been shipped fl at. Before framing, ensure the stand-offs are opened and screwed in place. It is not necessary to install a hearth extension, but the fi replace should be raised to be fl ush with either the hearth or the fi nished fl oor. When roughing in the fi replace, raise the fi replace to accommodate for the thickness of the fi nished fl oor materials, i.e. tile, carpeting, hard wood. Objects placed in front of the fi replace should be kept a minimum of 48” away from the front face. IMPORTANT: The requires a minimum inside enclosure height of 72”. For temperature requirements, this area must be left unobstructed. It is recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. Non-combustible finishing material (ie: cement board, brick, stone, tile) may be...

Other models in this manual:
Other Home Accessories - GD82NT-T (2.97 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category