Login:
Votes - 2, Average rating: 3.5 ( )

User manual Weslo, model Daybreak 207 WLHS20702

Manafacture: Weslo
File size: 687.46 kb
File name: b2fc49c7-0ba9-415e-95d9-f023fa76971f.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


STARTING THE SPA Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONSOLE below). The pumping unit will heat the water as it pumps. Cover the spa with the spa cover and liner. The spa cover must be tight. (See SECURING THE SPA COVER at the right.) The water will heat at about 3.0° F per hour with the cover on. If you are using the spa indoors and the room temperature is maintained at 70° F, it will take approximately 10 to 20 hours for the water to reach the set temperature. The temperature and water flow can be set or changed by the controls on the console (see USING THE CONSOLE below). USING THE CONSOLE The function of each console control is explained below and to the right: Air Temperature Control Control Pump Control Temperature Control: This control is used to set the temperature of the water. The water heats at about 3.0° F per hour with the cover on. The thermostat can be set to heat the water from 70° F to 104° F. Always use an accurate thermometer to check the temperature of the water. Note: The spa features automatic freeze protection. If the water temperature falls below 40° F, the pump will begin circulating and heating the water to prevent the water from freezing. Pump Control: This control turns the thera-jets on and off. To turn the thera-jets on, press the control once. To turn the thera-jets off, press the control again. The thera-jets will remain off for 20 minutes. After 20 minutes, the pump will begin cycling to heat the water if the temperature falls below the minimum setting. Note: To keep the heat cycle from running, the power cord must be unplugged. Air Control: This control determines the amount of air flowing through the thera-jets during operation. If the control is turned counterclockwise, the amount of air will increase; if the control is turned clockwise, the amount of air will decrease. SECURING THE SPA COVER To secure the spa cover, snap the latches on the spa cover into the buckles on the side of the spa. To lock the buckles, insert the key and turn it clockwise 1/4 turn. To unlock the buckles, insert the key and turn it counterclockwise 1/4 turn. Key Latch Buckle After the spa cover is secured, you can further tighten it by adjusting the self- attaching flaps on each end of the spa cover. Always keep the buckles locked when the spa is not in use. Keep the keys in a safe place, out of the reach of children. Adjustment Flaps 11 SPA JET OPERATION A B B C ED Refer to the diagram above. The function of each feature is explained below: The three fixed thera-jets (A), located on one end of the spa, focus a water massage on your back. The three adjustable thera-jets (B) can be adjusted for a custom water massage. One of the jets focuses a water massage on your lower back, a second jet focuses a water massage on your upper back, and a third jet near the floor of the spa focuses a water massage on your legs. Note: The adjustable thera-jets can be closed and opened by pushing and pulling the nozzles. If no air flows through the thera-jets when the air control is turned counterclockwise, simply pull the nozzles slightly. The filter (C) can be removed for cleaning and replacement (see CHECKING AND CLEANING THE FILTER on page 13). The suction vents (D), located near the floor of the spa, bring water into the pump in order to operate the system. The suction covers should always be in place over the suction vents. Never operate the spa without the suction covers in place. The spa is ozone ready. An optional ozone generator can be installed to utilize the ozone jet (E). Ozone provides a way to help sanitize your spa with minimal chemical treatment. 12 MAINTENANCE The spa is designed to provide years of enjoyment. Follow the guidelines below to properly maintain the spa. MAINTENANCE SCHEDULE DAILY • Check the water level. If necessary, refill the spa to the level shown in step 3 on page 8. • Adjust the pH balance and sanitizer level if needed (see WATER CHEMISTRY on page 14). WEEKLY • Clean the spa shell at the waterline. • Check and thoroughly clean the filter (see CHECKING AND CLEANING THE FILTER on this page). • Replace the filter if needed (see ORDERING REPLACEMENT PARTS on the back cover). MONTHLY • Clean the spa cover (see MAINTAINING THE SPA COVER below). • Soak the filter for two hours in a trisodium phosphate (TSP) solution. Rinse the filter in clean water. • Replace the filter if needed (see ORDERING REPLACEMENT PARTS on the back cover). EVERY THREE MONTHS • Drain the spa and refill it with clean water. Sanitize and test the pH of the water. • Check for any leaks around the pump or joints in the pipes. The seals will wear out over time; detecting leaks early can reduce repair costs. • Clean the interior of the spa. Do not use solvents or waxes. MAINTAINING THE SPA COVER The spa cover should be cleaned monthly. To clean the spa cover, hang it over a clothesline and spray it...

Other models in this manual:
Other Home Accessories - Daybreak 207 WLHS20702 (687.46 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category