Login:
Votes - 4, Average rating: 4.3 ( )

User manual American Standard, model 2422L/LA/V/VA

Manafacture: American Standard
File size: 1.84 mb
File name: 20df35d3-b4a4-452e-ac8a-094f9410eca3.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Fig. 2Fig. 3Fig. 1WARNING: Prior to operation, review the Important Safety Instructions listed at the beginning of this instruction manual. Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath. Pressure SwitchThe heater is equipped with a preset pressure switch. The pump must be running with water flowing in the whirlpool to allow the heater to turn on. Indicator LightThis light turns on whenever the heater is operating. High-Limit SwitchThe heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician. To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. ( ) Drain water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. ( ) The heater circuit will automatically reset in less than 15 minutes. (5) Restore power to the heater. ( ) Whirlpool bath is now ready to use. ELECTRICAL DIAGRAMREAD AND FOLLOW ALL INSTRUCTIONSBLACKWHITE120 VACGND. SEPARATE 20 AMP GFCI OUTLETfor2.1 H.P. PUMPSEPARATE 15 AMP GFCI OUTLETfor 1.6 H.P. PUMPPUMP/MOTORELECTRICAL INSTALLATIONHEATERBLACKWHITE120 VACGND. SEPARATE15 AMP GFCI OUTLETHEATER “ON” LIGHTBonding Lug onHeater HousingE-Z INSTALL™WHIRLPOOLHEATERRUN AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP/MOTOR FRAME LUG AND FROM PUMP/MOTOR LUG TO APPROVED GROUND AS SHOWN(PUMP/MOTOR) TO GROUNDSECOND COPPER CONDUCTORFIRST COPPER CONDUCTORPUMP/MOTOR FRAME WITH BONDING LUGSHEATER ONE-Z INSTALL™WHIRLPOOLHEATERFACTORY INSTALLED - NOT FOR RESALEHEATER P/N: 753174-100(HEATER) DRAIN CONNECTION AND SYSTEM TESTUsing recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point " above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occurred during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool is running. POST INSTALLATION CLEAN-UPRemove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface. Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water. Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint. AFTERCARE and CLEANING• The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance. • Always fill the tub with temperate water. Excessively hot water may cause surface damage• Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage. • Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray or concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner, or cleaning products in aerosol cans. HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES. • Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits,or other surface blemishes. • Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses its sheen, dulled areas can be restored by rubbing with a white "automotive type" polishing compound and waxing with a "liquid wax." • Do not wax areas where you walk or stand. • Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into contact with the surface. • Clean the surrounding surface immediately after using caustic drain cleaners. • Burning cigarettes will damage the surface. • Should damage to the fixture occur, repairs can be made quickly and easily. Your distributor or builder can provide details. • Do not permit drain cleaner to enter the circulation system. CIRCULATION SYSTEM CLEANING-PURGING PROCEDURESSTEP 1. Once every month purge and clean the circulating system. Fill whirlpool with warm water and add two teaspoons of dishwasher detergent and one-half cup of house hold bleach. STEP 2. Activate whirlpool system in accordance with operating instructions or two minutes. STEP 3. Drain and refill whirlpool with cool water and circulate for additional five minutes. STEP 4. Drain whirlpool comp...

Other models in this manual:
Other Home Accessories - 2711L (1.84 mb)
Other Home Accessories - 2425L/V - LHO (1.84 mb)
Other Home Accessories - 2425L/V -RHO (1.84 mb)
Other Home Accessories - 2645L (1.84 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category