|
manual abstract
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS : • Do not try to light any appliance. • Do not touch any electrical switch; • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency, or the gas supplier. SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers. WARNING: Improper installation, adjustment, alteration, service, or maintenance to this appliance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. CHECK LOCAL CODES PRIOR TO INSTALLATION WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. WARNING: This Direct-Vent Gas Fireplace series is intended for use with Natural or Propane/LP gas only. Do not attempt to burn any solid fuels in these appliances. (Peninsula Shown) ® DIRECT-VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN Alternate Left Side TOP VIEW Bottom Gas Surround Supply Inlets Back of Surround (Left Side) 23 5/8 (60cm) (Front) (Back) Right Side Surround (27cm) (27cm) Top Spacer RIGHT SIDE Rating Plate Location Figure 1 - EVDDVF36PN (Peninsula) Dimensions Alternate TOP VIEW Left Side Bottom Gas Surround (Left Side) Supply Inlets Back of Surround (Back) Right Side (27cm) (28cm) Surround Top Spacer RIGHT SIDE Rating Plate Location 22 5/8 (57cm) 1 7/8 (5cm) Figure 2 - EVDDVF36STN (See Thru) Dimensions (Right Side) 10 1/2 o1.5 (4cm) o1.5 (4cm) 10 1/2 11 15/16 (30cm) 1 1/4 (3cm) 22 5/8 (57cm) 41 1/8 (104cm) 32 (81cm) (Opening) 1 7/8 (5cm) (Right Side) (Front) 23 5/8 (60cm) 11 15/16 (30cm) 10 1/2 o1.5 (4cm) o1.5 (4cm) 11 1/8 43 1/8 (110cm) 32 (81cm) (Opening) 1 1/4 (3cm) BACK VIEW (76cm) (Opening) 39 3/4 (101cm) 26 3/8 (67cm) 3 (8cm) 1 (3cm) 2 (5cm) 22 5/8 (57cm) 34 3/4 (88cm) 3 (8cm) FRONT VIEW 30 25 (64cm) 19 7/8 (50cm) (Opening) BACK VIEW FRONT VIEW 39 3/4 (101cm) 26 3/8 (67cm) 3 (8cm) 1 (3cm) 2 (5cm) 3 (8cm) 22 5/8 (57cm) 34 3/4 (88cm) 30 (76cm) (Opening) 23 5/8 (60cm) 25 (64cm) GLOSSARY OF TERMS Chase - A box-like enclosure to protect venting from the elements when the venting run is on the outside of a structure. Mastic - A pliable sealant for use around the vent terminal. Snorkel Termination - A box that raises the horizontal termination above ground level clearances. Vent Terminal - Mounted on an outside wall or roof to separate the inlet and outlet of the vent system and protect it from weather. Vinyl Siding Standoff - A metal box that separates the vent cap from vinyl siding. Wall Thimble/Firestop - A metal plate used to secure the vent pipe when it passes through a wall or ceiling. Note:All dimensions in this manual are in inches unless otherwise specified. 2 106573 106573 3 OWNER’S MANUAL Model EVDDVF36PN series is a three-sided direct-vent gas fireplace with a sealed combustion chamber. Model EVDDVF36STN series is a two-sided direct-vent gas fireplace with a sealed combustion chamber. These models are equipped with an electronic direct spark ignition system and require household electricity to operate. A fan kit is available for these models as an option (see Accessories on page 26). INTRODUCTION WARNING: Installation and repair should be done by a qualified installer/service person. The appliance should be inspected before use, and at least annually thereafter by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding, pet hair, etc. It is imperative that the control compartments, burners, and circulating air systems be kept clean. NOTICE: This appliance is intended to be used only for supplemental heat. • Models EVDDVF36PN and EVDDVF36STN use NATURAL GAS ONLY. If you have any doubts as to which gas your particular appliance is approved and tested for, please check the AGA/CGA rating plate located at the interior of the appliance opening or consult your local distributor (see Figures 1 and 2, page 2). BEFORE YOU BEGIN Before beginning the installation of your appliance, read these instructions through completely. This DESA appliance and its approved components are safe when installed according to this in...
Other models in this manual:Other Home Accessories - EVDDVF36STN (683.8 kb)