Login:
Votes - 4, Average rating: 4.5 ( )

User manual Bloomfield, model 2288EX

Manafacture: Bloomfield
File size: 1.62 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or decanters. 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove decanters. 3. Remove and empty brew chamber. 4. Remove the spray disk from the brew head: Press up on the spray disk ears, then turn the disk to the left to unlatch. Remove the gasket from inside the brew head. 5. Wipe inside of brew head and area around the brew head with a soft clean cloth or sponge moistened with clean water. 6. Wash the spray disk in a sink using warm water and a mild detergent. A bristle brush may be used to clear clogged spray holes. Rinse the spray disk with clean water and allow to air dry. 7. Wash the brew chamber in a sink using warm water and a mild detergent. A bristle brush may be used to clean the inside. Rinse with clean water and allow to air dry. 8. Wipe all warmer plates and the exterior of the brewer with a soft clean cloth or sponge moistened with clean water. 10. Reinstall the gasket INSIDE the brew head, then reinstall the spray disk. 11. Reinstall the brew chamber. 12. Do not submerge airpots or thermal servers in water. Airpots and thermal servers may be cleaned with a bottle brush and warm soapy water. Wipe exterior with a cloth moistened with water and mild detergent. Be sure airpots and thermal servers are well rinsed and dry before use. Procedure is complete 8 SERVICING — OPERATIONAL ADJUSTMENTS A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer D. Adjust Dripout Timer E. Adjust After Hours Timer A B C D E UNDER TOP COVER (IN SECONDS) BREW TIMER (IN °F) BREW TEMP (IN 5 MIN INCR) QUALITY TIMER (IN SECONDS) DRIPOUT TIMER (IN ONE HR INCR) AFTER HOURS TIMER WATER LEVEL PROBE TEMP PROBE 20185 6OFF 360 9030 70 120 OFF 194 205 OFF 210 320 100 CAUTION: Electric Shock Hazard Unplug or disconnect the brewer from electric power before removing the top cover IMPORTANT: Adjustments must be performed by a qualified technician ONLY. 1. Access the Controls: All adjustments on the E-Max™ LX may be accessed by removing the top cover or top warmer station from the brewer. The adjustments are directly behind the front panel. 2. Adjust Brew Time: The time the brew solenoid is open maybe adjusted by turning the shaft of the left-most control (A). Turning the shaft clockwise increases the time. Ten degrees of rotation is approximately equal to seven seconds change. Adjust until a complete brew is achieved without overflowing the airpot or server. 3. Adjust Brew Temperature: Ideal brewing temperature is 195.F to 205.F. Realistically, the maximum brew temperature is the local boiling temperature minus 10.F. To adjust the temperature, turn the shaft of the second control (B). Turning the shaft clockwise increases temperature. Fifteen degrees of rotation is approximately equal to 1-1/4.F. 4. Quality Timer: (not used on airpot and thermal brewers). 5. Adjust Dripout Timer: This feature disables the brew switch for an amount of time to allow all water to finish dripping through the grounds. The length of time may be adjusted by turning the shaft of the fourth control (D). Turning the shaft clockwise increases the time. Ten degrees of rotation is approximately equal to 2-1/2 seconds. 6. Adjust After Hours Timer: This feature places the brewer into an energy-saver mode if no brew has been initiated for a length of time. Time may be adjusted by turning the shaft of the fifth control (E). Turning the shaft clockwise increases the time. Turning the shaft fully counterclockwise turns the After Hours function off. Adjustment is in one hours increments. 9 SERVICING INSTRUCTIONS — ELECTRICAL FILL SOLENOID WATER LEVEL PROBE CONTROLLER FILL BREW BREW TIME BREW SOLENOID DRIP OUT TIME BREW CANCEL CONTROLLER BREW WATER TEMP PROBE BREW TEMP TRIAC HEATING ELEMENT THI-LIMIT STAT LINE VOLTAGE CONTROLLER WATER TEMPERATURE OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2. Automatic fill is accomplished via a FILL SOLENOID (32) and a WATER LEVEL PROBE (7). The probe senses ground through the water in the tank. When the water level falls below the probe and ground is no longer sensed, the CONTROLLER (20) energizes the fill solenoid until the water level again reaches the water level probe. 3. Pressing the BREW key begins the brew cycle. Pressing the CANCEL key at any time during the brew cycle terminates the brew. The BREW SOLENOID (18) is energized by the CONTROLLER (20) for a time determined by the setting of the BREW TIME CONTROL. A second brew can be started only after the brew time plus the time set on the DRIP OUT TIMER has elapsed. 4. Brew water temperature is controlled via a water temperature sensor and a HEATING ELEMENT (15) controlled by a TRIAC (17) electronic switch. The element is energized according to the sensed water temperature and the desired temperature setting...

Other models in this manual:
Other Kitchen Appliances - 2280 (1.62 mb)
Other Kitchen Appliances - 2282 (1.62 mb)
Other Kitchen Appliances - 2286EX (1.62 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category