manual abstract
Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position. E L E C T R I C A L VOLTAGE PHASE CYCLE/HZ AMPS KW 120/208-240 (AGENCY) 1 50/60 AT 208 1 50/60 AT 240 1 50/60 13.8 11.6 13.0 3.3 2.5 3.1 NEMA L14-20P 20A, 250V PLUG 230 (AGENCY) 1 50/60 230 1 50/60 12.6 12.6 2.9 2.9 BARE END, NO PLUG VOLTAGE PHASE CYCLE/HZ AMPS KW 120/208-240 (AGENCY) 1 50/60 AT 208 1 50/60 AT 240 1 50/60 18.75 19.0 19.0 4.5 4.6 4.6 NEMA L14-30P 30A, 250V PLUG 230 (AGENCY) 1 50/60 230 1 50/60 18.3 18.4 4.2 4.2 BARE END, NO PLUG VOLTAGE PHASE CYCLE/HZ AMPS KW 120/208-240 (AGENCY) 1 50/60 AT 208 1 50/60 AT 240 1 50/60 24.0 24.0 24.0 5.2 5.2 5.2 NEMA L14-30P 30A, 250V PLUG 230 (AGENCY) 1 50/60 230 1 50/60 24.3 24.7 5.6 5.7 BARE END, NO PLUG Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes. DANGERELECTRICALCONNECTIONSMUSTBEMADEBYAQUALIFIEDSERVICETECHNICIANINACCORDANCEWITHAPPLICABLEELECTRICALCODES. DANGERToavoidelectricalshock,thisapplianceMUSTbeadequatelygroundedinaccordancewithlocalelectricalcodesor,intheabsenceoflocalcodes,withthecurrenteditionoftheNationalElectricalCodeANSI/NFPANo.70.InCanada,allelectricalconnectionsaretobemadeinaccordingwithCSAC22.1, CanadianElectricalCodePart1orlocalcodes. DANGERENSUREPOWERSOURCEMATCHESVOLTAGESTAMPEDONAPPLIANCENAMEPLATE. REGARDING INTERNATIONAL STANDARD UNITS: If the unit is not equipped with flexible cord with plug, an all-pole country approved disconnection device which has a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring for disconnection. When using a cord without a plug, the green/yellow conductor shall be connected to the terminal which is marked with the ground symbol. If a plug is used, the socket outlet must be easily accessible. If the power cord needs replacement, use a similar one obtained from the distributor. For 230V units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol. HN2 & HN2SYS Series Operation & Care Manual • 5 INSTALLATIONINSTALLATION HN2 & HN2SYS SERIES OPTIONS & ACCESSORIES DESCRIPTION HN2-48 SERIES HN2-72 SERIES HN2-96 SERIES BUTTING KIT AVAILABLE AVAILABLE AVAILABLE GAUGE, INTERIOR AMBIENT TEMPERATURE GU-33384 GU-33384 GU-33384 GLASS, TEMPERED END PANE, BRONZE KIT 5008529 5008529 5008529 INDEPENDENT ELECTRICAL OUTLET 5001781 5001781 5001781 PANEL KIT, COUNTER TOP BRUSHED STAINLESS STEEL CUSTOM COLOR 5004595 5004596 5004597 5004598 5004599 5004600 PANEL KIT, SYSTEM BRUSHED STAINLESS STEEL CUSTOM COLOR 5004601 5004602 5004603 5004604 5004605 5004606 PAN INSERT, SELF SERVICE 4" (102mm) DEE...
Other models in this manual:Other Kitchen Appliances - HN2-48 (1.98 mb)
Other Kitchen Appliances - HN2-96/PR (1.98 mb)
Other Kitchen Appliances - HN2SYS-96/PR (1.98 mb)
Other Kitchen Appliances - HN2-96 (1.98 mb)