Manafacture: Bloomfield
File size: 1.12 mb
File name: bdf3123e-610a-419f-ac49-603fe405f2cf.pdf
|
manual abstract
Place the appropriate EMPTY dispenser in place under the brew chamber. If a brew-thru lid is used, be sure the bypass opening in the lid is directly under the bypass nozzle. Press the “BREW” switch. The brew solenoid will open for an amount of time determined by the timer setting, admitting a measured quantity of water into the tank. Inlet water will displace a like amount of heated water from the tank. The hot water will be forced into the brew head where it will spray over the bed of grounds. Freshly brewed tea will begin to fill the dispenser. Additionally, a measured amount of cold dilution water will flow from the bypass nozzle into the dispenser. When the flow and all dripping stops at the end of the brew cycle, the tea is ready to serve. Discard the contents of the brew chamber and rinse it in a sink. When the ”READY TO BREW” light glows, the brewer is ready for another brew cycle. 608 p/n 76467 8740 Tea Brewer Owners Manual 8 CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS PROCEDURE: Clean Tea Brewer CAUTION: BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of tea are FREQUENCY: Daily extremely hot. Hot tea will cause serious skin TOOLS: Mild Detergent, Clean Soft Cloth or Sponge burns. Bristle Brush, Bottle Brush 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove dispenser. 3. Remove and empty brew chamber. 4. Remove the spray disk from the brew head (See figure 8): Press up on the spray disk ears, then turn the disk to the left to unlatch. Remove the gasket from inside the brew head. 5. Wipe inside of brew head and area around the brew head with a soft clean cloth or sponge moistened with clean water. 6. Wash the spray disk in a sink using warm water and a mild detergent. A bristle brush may be used to clear clogged spray holes. Rinse the spray disk with clean water and allow to air dry. 7. Wash the brew chamber in a sink using warm water and a mild detergent. Rinse with clean water and allow to air dry. 8. Wipe the exterior of the brewer with a soft clean cloth or sponge moistened with clean water. 10. Reinstall the gasket INSIDE the brew head, then reinstall the spray disk. 11. Clean dispensers by filling with warm soapy water. Empty and rinse with clean water. Wipe the exterior with a soft clean cloth or sponge moistened with clean water. Invert and allow to air dry. Procedure is complete CAUTION: SHOCK HAZARD Do not submerge or immerse brewer in water. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or dispensers. Fig. 8 Cleaning 608 p/n 76467 8740 Tea Brewer Owners Manual 9 TROUBLESHOOTING SUGGESTIONS TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Tank heater switch OFF Press switch to ON Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit will self- reset Damaged internal component or wiring Examine wiring & connectors, controller, power board and heating element Repair/replace as needed Tea level too high or low Timer out of adjustment Adjust timer Brew chamber overflows Too many filter papers or wrong filter paper Brew chamber dispense hole plugged Too much tea leaves Use one (1) genuine Bloomfield filter per brew Thoroughly clean brew chamber Use correct amount of tea Sprays water from brew head Spray gasket improperly Check/reinstall gasket on installed INSIDE of brew head No brew Spray disk plugged Clean spray disk Damaged internal component or wiring Check switches, timer and solenoid. Repair, replace as needed Water supply OFF Turn water supply ON Solenoid inlet strainer plugged Clean strainer Water filter (if used) plugged Replace filter element Keep brewer and dispenser clean. Poor tea quality Install a taste and odor filter in water supply, and replace cartridges regularly. Use a quality fresh supply of tea leaves. Use amount of tea leaves appropriate to brew volume. 608 p/n 76467 8740 Tea Brewer Owners Manual 10 SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access panels on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel. NOTE ; Time and temperature controls may be accessed without removing cabinet panels by removing the appropriate hole plug from the top wrap. ACCESS PLUGS Use a small flat-blade screwdriver or similar implement to pry the hole plug from the access hole in the top wrap. HOT WATER TEMPERATURE: Remove right 7/8" hole plug to access temperature control. WATER DELIVERED VOLUME: Remove left 2" hole plug to access water volume timer. ACCESS PANELS TOP WRAP: Remove top wrap to access hot water tank, thermostat, timer, switches and brew circuit tubing. Top wrap is held by two screws at the front and two screws at the rear. REAR PANE...