Login:
Votes - 3, Average rating: 4.7 ( )

User manual Lanier, model LD020C

Manafacture: Lanier
File size: 13.62 kb
File name: cp397.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Issued: Supersedes: Date: Prepared by: Approved by: European Contact: CP- 397 02/10/2003 none 02/10/2003 EH&S Department 770-496-9500 Larry Choskey, Manager, CEH&S Walter Fricke, Manager, Safety & Environment, Lanier Worldwide, Inc. Im Taubental D-41468 Neuss, Germany +49-2131-387-177 Section 2: Composition / Information on Ingredients PERCENT CAS No. EXPOSURE LIMITS SOURCE Polyester resin > 80 Confidential Not listed N/a Acrylic resin <10 Confidential Not listed N/a Organic pigment <10 5281-04-9 Not listed N/a Silicon compound <3 7631-86-9 Not listed N/a Section 3: Hazards Identification HMIS Rating: FLAMMABILITY = 1 HEALTH = 1 REACTIVITY = 0 SPECIAL = none Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort. Health Hazards of Long Term exposure (Chronic): None Target Organs: Prolonged breathing of high concentrations of this product may cause adverse effects on the respiratory system. Medical Conditions Aggravated by exposure to this product: Respiratory disorders, such as asthma, may be aggravated by exposure to high concentrations of this product. This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200. Section 4: First Aid Measures Gargle with water. Remove to fresh air if effects In case of contact, immediately flush Inhalation: occur. Get medical attention if needed. Eye Contact: eyes with water for 15 minutes. Get medical attention if needed. Skin Contact: Wash with soap and water. Ingestion: Dilute stomach contents with several glasses of water. Get medical attention. Section 5: Fire Fighting Measures Suitable extinguishing media: CO2, dry chemical, foam or water. Extinguishing media which may not be used for safety reasons: none Special protective equipment for fire fighters: none UEL: n/a LEL: n/a your document management partner J:\EHS\MSDS\Toner\Docs\cp397.doc MATERIAL SAFETY DATA SHEET Page 2 of CP-397 Section 6: Accidental Release Measures Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix AAA Toner Vacuum or 3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal injury. Remove residue with soap and cold water. Miscellaneous: Keep product out of sewers and watercourses. Personal protection: Avoid inhalation of dust. Section 7: Handling and Storage Special Handling: Cleanse skin after contact before breaks or meals, and end of workday. Do not handle in areas where the wind blows. Minimize the breathing of dust. Special Storage: Avoid direct sunlight. Keep out of reach of children. Store in a cool, dry place. Below 35C (95F) Section 8: Exposure Control and Personal Protection Information: Respiratory Protection: none required under normal use. Hand Protection: none required under normal use. Eye Protection: none required under normal use. Skin Protection: none required under normal use. Section 9: Physical and Chemical Properties CHARACTERISTICS: Appearance: Magenta Melting point: N/a Form: Powder Vapor pressure: N/a Odor: Slight plastic odor Vapor density: N/a Solubility in Water: Insoluble Evaporation rate: N/a Specific gravity: N/a Boiling point: N/a Bulk Density: 1.2 Section 10: Stability and Reactivity Conditions to avoid: none Materials to avoid: none Stability: Stable Hazardous decomposition products: Will not occur Section 11: Toxicological Information: Ames test negative Acute skin irritation: n/a Acute oral toxicity: >5000mg/kg (rat) Acute allergenic effects: n/a Special effects: Carcinogenicity: None Section 12: Environmental / Ecological Information Acute toxicity to fish: n/a Bioaccumulation: Not known in bioaccumulation Persistence/Degradability: Not known Acute toxicity to daphnia: Not available Algae inhibition test: Not available Section 13: Disposal Consideration Used Toner should be disposed of under conditions that meet all federal, state and local environmental regulations. Disposal regulations vary from locality to locality; therefore consult your local Lanier office or the EPA to determine the proper method for disposal. Do not incinerate loose or spilled Toner. Section 14: Transportation Information International regulations: RID/ADRNot applicable ICAO-TI/ATA-DGR Not applicable DOT 49 CFR Not applicable UN Classification Number Not applicable ADNR Not applicable IMDG Code Not applicable Specific precautionary transport measures: Avoid direct sunlight. Do not keep over 35?C (95?F). Specific material to avoid: None in normal use. J:\EHS\MSDS\Toner\Docs\cp397.doc MATERIAL SAFETY DATA SHEET Page 2 of CP-397 Regulation: Not known Section 15: Regulatory Information Section 16: Miscellaneous Information Judgment as to the suitability of information contained herein for user’s purposes is the resp...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category