Login:
Votes - 4, Average rating: 3.3 ( )

User manual Hatco, model GLO-RAY GRH

Manafacture: Hatco
File size: 425.8 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Dual units must always have a minimum spacing of 3" (76 mm) between heaters. T-Legs or C-Legs Do not mount units longer than 72" (1829 mm) on T-legs or C-legs. Over Steam Table When mounting over steam table, a remote control switch enclosure must be installed. CAUTION Unit is not moisture proof. Spacing of at least 16" (406 mm) is required for all units mounted over a steam table. Figure 10. Recommended Element Height for the GR, GRA, GRH, GRN, GRAH, GRAL, GRNH, and GRAHL in all lengths (excluding dual models). 11"-14" (279-356 mm) 15" (381 mm) High Wattage Standard Wattage 4"-6" (102-152 mm) 8"-11" (203-279 mm) High Wattage Standard Wattage 12" (305 mm) Figure 11. Recommended Element Height for the GRA-D, GRAH-D, GRAL-D & GRAHL-D Models with a 3" (76 mm) spacer in all lengths. 21" (533 mm) 14"-18" (356-457 mm) 10"-14" (254-356 mm) 18" (457 mm) High Wattage Standard Wattage Figure 12. Recommended Element Height for the GRA-D, GRAH-D, GRAL-D & GRAHL-D Models with a 6" (152 mm) spacer in all lengths. 24" (610 mm) 14"-18" (356-457 mm) 10"-14" (254-356 mm) Form No. GRM-0707 12 INSTALLATION ASSEMBLY Glo-Ray® Strip Heaters are shipped with most components pre-assembled. Dual units are available with a required 3" (76 mm) or 6" (152 mm) spacer pre-assembled at the factory. Optional breath protectors, mounting equipment and remote control enclosures must be installed on location. PORTABLE SURFACE MOUNT T-Leg Stand NOTE: T-Leg not to be used with dual Glo-Ray units. NOTE: T-Leg stands available in standard wattage 10" (254 mm), high wattage - 13-1/2" (343 mm), 16" (406 mm), and 18" (457 mm). 1. Position the unit upside-down on a flat surface. 2. Remove the two screws and mounting tabs from each end of the unit. 3. Position the mounting bracket on the underside of the unit and remove the two screws on the unit that match up with the holes on the mounting bracket. 4. Secure the mounting bracket to the unit with the previously removed screws. 5. Align two mounting holes on side of T-Leg with two holes on end of unit and attach leg with screws supplied. 6. Align the mounting hole on the T-Leg bracket with the hole on the mounting bracket and secure with a screw. (See Figure 13.) C-Leg Stand NOTE: C-Legs are not to be used with dual Glo-Ray models. NOTE: Two types of C-Legs are available. CL-Low, 10" (254 mm) clearance, is for standard wattage Glo-Ray models up to 6 ft. (1829 mm) in width only. CL-High, 13-1/2" (343 mm) clearance, is for high wattage Glo-Ray models up to 6 ft. (1829 mm) in width only. 1. Position the unit upside-down on a flat surface. 2. Remove the two screws and mounting bracket from each end of the unit. T-Leg Bracket T-Leg Figure 13. T-Leg Stand End Mounting Figure 14. C-Leg Stand 3. Attach C-Leg to each end of unit using original screws. (See Figure 14.) Tighten screws securely. 13 Form No. GRM-0707 INSTALLATION PERMANENT SURFACE MOUNT Tubular Stand Mounting Tubular stand mounting permanently attaches the unit to a countertop or serving table. All wiring may be concealed within the tubular stand. Tubular stands are available in non-adjustable heights from 10"-16" (254-406 mm) or in adjustable heights from 10"-14" (254-356 mm). NOTE: Tubular stands are not field retro-fittable. NOTE: If wiring is to be concealed, a 1" (25 mm) diameter hole must be provided in the mounting surface, centered under the leg flange nearest the electrical wiring hookup. 1. Position the unit upside-down on a flat surface. 2. Units for this application are supplied with the conduit attached. Conduit should not be removed. 3. If applicable, route flexible conduit through the leg opening. Pull the leg up to the underside of the warmer. (See Figure 15.) 4. Secure legs to warmer using screws supplied. 5. If applicable, route the flexible conduit through opening in countertop. 6. Secure the legs to the mounting surface. NOTE: The adjustable legs can be raised or lowered by turning the locking set screw counterclockwise one turn with an allen wrench, and then raising or lowering the unit to the desired height and retightening the screw. Do not loosen the screw more than necessary. NOTE: Two pairs of legs will be needed for mounting dual units. Figure 15. Tubular Stand Mounting Locking Screw Covers Adjustable Leg Non-Adjustable Leg Flexible Conduit Form No. GRM-0707 14 INSTALLATION UNDERSHELF MOUNTING Pass Thru NOTE: When mounting the unit under a shelf, it is recommended to use a remote switch enclosure. If the shelf has a rolled or flanged edge, use the optional adjustable angle brackets to mount the unit below the lowest part of the rolled or flanged edge. (See Figure 16.) NOTE: GRN Series units are supplied with matching Designer colored angle brackets providing 1-1/2" (38 mm) clearance between foodwarmer and overshelf. CAUTION To assure safe and proper operation refer to Installation Clearance Requirements listed in this manual. Adjustable Angle Bracket Mounting NOTE: When mounting the unit under a shelf it is recommended to ...

Other models in this manual:
Printers - GLO-RAY GRA (425.8 kb)
Printers - GLO-RAY GRAHL (425.8 kb)
Printers - GLO-RAY GR (425.8 kb)
Printers - GLO-RAY GRAH (425.8 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category