Login:
Votes - , Average rating: ( )

User manual Marmitek, model SD833

Manafacture: Marmitek
File size: 594.76 kb
File name: 2f088c20-ffc6-47b8-873b-b5c836059592.pdf

Language of manual:itenesfrdenl

The document is loading, please wait
The document is loading, please wait

manual abstract


Test the alarm for correct operation using the test button whenever the battery is replaced. If the power indicator light ceases flashing, replace the battery. Be sure to replace the battery as soon as possible to ensure proper operation and to avoid a leaking battery. Leakage could cause damage to the alarm, furniture and carpeting. WARNING: Use of any other battery than specified in the technical data may be detrimental to the operation of the Smoke Detector d. Cleaning your Smoke Detector Clean your smoke detector regularly. Use a soft bristle brush or the brush attachment of your vacuum cleaner to remove dust from the sides and cover slots where the smoke enters. Keep cover closed while cleaning. Do not vacuum or brush inside the Smoke Detector. To clean the cover, remove it completely and use only mild soap and water. Dry cover thoroughly before replacing it. WARNING: Do not paint your smoke detector. Other than the maintenance and cleaning described in this leaflet, no other customer servicing of the product is required. Repairs, when needed, must be performed only by the manufacturer. 7. INTERCONNECTING YOUR SMOKE DETECTORS A maximum of 12 SD833 Smoke Detectors may be wired together such that when one unit senses smoke all other units sound a warning. This helps ensure smoke alarms will be heard. Do not connect to any other device as it may damage the unit or Figure 2 affect performance. SD833 A maximum of 1,500 meters (5,000 feet) of 18 AWG (0.82mm) wire can be used, (maximum resistance between detectors 50 Ohm). The units are interconnected by wiring all the terminals marked 1 together, and all the terminals marked 2 together (as in figure 2 before screwing to ceiling). Draught from wiring openings, conduit, or mounting boxes/holes, may blow smoke away from the sending chamber, making it insensitive. It is essential that all such openings be closed by silicone sealant or similar. After wiring together the interconnect smoke detectors, test the first unit by pressing the test button. All the detectors should alarm and the test button on the first unit will flash about once a second. Check all the other units similarly. 8. TECHNICAL DATA Antenna: Built-in Internal Whip Frequency: 868.35MHz FM Current Consumption: 30mA (transmission), 20.A (standby) Power: 9V Alkaline Battery RFI Immunity: 40V/m Ambient temperature: 0° C to + 60° C (operation) Dimensions: 138 x 118 x 44mm Specifications may be modified without prior notice. Environmental Information for Customers in the European Union European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. © MARMITEK SICHERHEITSHINWEISE • Der SD833 ist als Rauchmelder ausschlie.lich fur Verwendung im Haus gedacht. Bei Rauchentwicklung gibt der Rauchmelder einen eindringlichen Ton ab. Bringen Sie den Rauchmelder an einem Ort an, wo die eingebaute Sirene fur anwesende Bewohner horbar ist, auch wenn diese schlafen. Bringen Sie eventuell mehrere Rauchmelder an. Als zusatzliche Funktionalitat konnen Sie den Rauchmelder in Kombination mit Marmitek ProGuard800 Uberwachungssystem verwenden. Achtung: Bei Gebrauch dieser Zusatzfunktion kann der Fabrikant nicht haftbar gemacht werden. • Dieses Produkt ist kein Spielzeug. Au.er Reichweite von Kindern halten. • Uberprufen Sie wochentlich den Betrieb des Rauchmelders. • Um Kurzschluss vorzubeugen, dieses Produkt bitte ausschlie.lich innerhalb des Hauses und nur in trockenen Raumen nutzen. Setzen Sie die Komponenten nicht Regen oder Feuchtigkeit aus. Nicht neben oder nahe eines Bades, Schwimmbades usw. verwenden. • Setzen Sie die Komponente Ihres Systems nicht extrem hohen Temperaturen oder starken Lichtquellen aus. • Uberlassen Sie Reparaturen oder Wartung nur Fachleuten. • Bei einer zweckwidrigen Verwendung, selbst angebrachten Veranderungen oder selbst ausgefuhrten Reparaturen verfallen alle Garantiebestimmungen. Marmitek ubernimmt bei einer falschen Verwendung des Produkts oder bei einer anderen Verwendung des Produktes als fur den vorgesehenen Zweck keinerlei Produkthaftung. Marmitek ubernimmt fur Folgeschaden keine andere Haftung als die gesetzliche Produkthaftung. • Halten Sie die Batterien au.erhalb der Reichweite von Kindern. Liefern Sie die Batterien als chemischen Kleinabfall ein. Verwenden Sie niemals alte und neue oder unterschiedliche ...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category