Login:
Votes - , Average rating: ( )

User manual Sierra Monitor Corporation, model 2050

Manafacture: Sierra Monitor Corporation
File size: 89.31 kb
File name: gas_alarm_2050_2060.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Available as single channel monitors or part of multipoint alarm system The Model 2050 Ammonia and Model 2060 Refrigerant/ Halocarbon Gas Monitors are continuous duty, low cost stationary monitors for detection of high levels (50-500 PPM) of ammonia and halocarbon refrigerant gases. These monitors are primarily used in and around freezers, refrigerators, and compressor rooms to warn of leaks and dangerous levels of these gases. An alarm is activated when the concentration of gas exceeds the user-adjustable level. An alarm condition activates the alarm light on the front of the monitor and generates an output signal. An output signal can activate a remote alarm through the Model 2102 Alarm Panel. The Model 2102 Dual Channel can be connected up to 500 feet from the monitors. Each monitor also has a 0.5 amp, dry contact relay replaces the output signal. The monitors are housed in a polystyrene enclosure that is suitable for installation in freezer, refrigerator or other applications. Test connections and adjustment controls are located on the outside of the enclosure and are easily used, even when the operator is wearing hand protection. Alarms These monitors have two indicator lights on the front of the unit, a green “safe” indicator and a red “alarm” indicator. Three alarm conditions are possible. These can be detected visually at both the monitor and controller at all times. ■ Warm-up - Interrupted (On/Off) “red/green” visual indication when power is first connected to the monitor, followed by a red light until warm-up is completed and the green light comes on. ■ Gas Alarm - Sustained solid red light indicating the presence of gas at, or above, the pre-set threshold. ■ Sensor failure - Interrupted (on/off) “red/green” visual indication after unit has been in operation, indicating either a failed sensor or that the monitor is not correctly calibrated. The Model 2050 Ammonia monitor has a factory alarm setpoint of 100 ppm NH3. This setpoint is user adjustable in the field over a range of 50 to 500 ppm NH3. The Model 2050 calibration can be checked with Hydrogen gas. The Model 2060 Halocarbon monitor can be calibrated with Carbon Monoxide and the factory setpoint varies for the specific type of halocarbon present. The factory setpoint for R12 is 500 ppm while the setpoint for R134a is 50 ppm. See the specifications for more details. Temperature Range The Model 2050 and 2060 have temperature compensated circuitry to provide stabilization in temperatures ranging from -4o to 158oF. Semiconductor-Type Sensor A solid-state semiconductor-type sensor and associated electronic circuitry ensure trouble-free, long-term operation. There are no pumps, filters, or chemical cells to replace or maintain. Except periodic calibration to verify the alarm setting, no periodic maintenance is required after installation. The user may adjust the alarm level by using a different calibration gas concentration. Sierra Monitor Corporation 1991 Tarob Court Milp...

Other models in this manual:
Alarms - 2060 (89.31 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category