Login:
Votes - 4, Average rating: 4.3 ( )

User manual Fisher & Paykel, model DD24ST

Manafacture: Fisher & Paykel
File size: 2.94 mb
File name: 599754C_DD24S_TALL_installA2_USCAw.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Ensure hoses and cord are not kinked or twisted. optional * RECOMMENDED METHOD - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) ALTERNATIVE METHOD - SECURE BY DRAWER REMOVAL Tie together to avoid kinking. Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity. The mounting slots are in pairs, one on each side diagonally across the product. ‘A’ bracket must match ‘A’ slot and ‘B’ bracket must match ‘B’ slot. ‘B’ ‘B’ ‘B’ ‘B’ ‘B’ ‘A’ ‘A’ ‘A’ ‘A’ ‘A’ ‘A’ ‘B’ Tie together to avoid kinking OR OR If top mounting brackets are being used *, ensure they’re securely fitted before sliding product into cavity. * If cavity bracket for 18 7.8”(480 mm) cavity is fitted, the top mounting brackets cannot be used. (1,2) -2- 599754C DD24S TALL installA2 USCA.indd 15/4/09 2:34:43 PM 1 2 1 3 3 optional (x2) MOVE INTO THE CAVITY SECURE THE DRAWER SECURE THE DRAWER REFIT THE DRAWER 10 10 11 11 1 2 3 The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. 2 1 4 5 4 3 Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. Ensure the drawer clips on both sides are reset. Ensure the drawer is now rotated clockwise back. Ensure hoses and cord optional are not kinked or twisted. OPTIONAL 1 2 3 4 4 optional max. . ” (19 mm) Open the drawer halfway. Using a flat-bladed screwdriver, prize the plastic gray plug out of the trim moulding. Replace the plastic gray plug back into the trim moulding and ensure the trimseal is facing forward. Repeat for all four brackets. Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the rubber trimseal. If top mounting brackets are being used, ensure they’re securely fitted before sliding product into cavity. max. . ” (19 mm) a pair of optional brackets on the top a pair of fixing holes on the bottom a pair of formed brackets on the chassis side (2,1) -2- 599754C DD24S TALL installA2 USCA.indd 15/4/09 2:34:43 PM 29 .” - 34 .” (750 - 882.5 mm) 1 .” (38 mm) max. 4 .” (120 mm) 2 1 4 1 6 5 4 7 2 29 .” - 34 .” (750 - 882.5 mm) 3 1 4 3 2 5 5 4 3 6 A If space is limited for fixing, push hose through drain hose support to required height DishDrawer® with Waste Disposal 29 . ” - 34 . ” (750 - 882.5 mm) min. R 8 ” (200 mm) min. R 8 ” (200 mm) Supplied drain hose joiner (o . ” (19 mm)) waste tee) HIGHLOOP min. 6” (150 mm) DishDrawer® using Air Break with Drain Hose Joiner Supplied drain hose joiner (o . ” (19 mm)) waste tee) Air Break 37 3.8” (950 mm) Max. height to top of Air Break (countertop or wall mounted) Ensure hoses are routed straight to joiner. Remove excess hose material if necessary. DishDrawer® and Standpipe O 1 1/2” (38 mm) 29 . ” - 34 . ” (750 - 882.5 mm) min. R 8 ” (200 mm) Waste Disposal (optional) 12 PLUMBING AND DRAINAGE OPTIONS B Fit supplied rubber washer Fit supplied rubber washer Fit supplied rubber washer Ensure hoses are routed straight to joiner. Remove excess hose material if necessary. C If space is limited for fixing, push hose through drain hose support to required height 180o 180o 180o (2,1) -3- 599754C DD24S TALL installA2 USCA.indd 15/4/09 2:35:39 PM (2,2) -3- 59754C D24S TAL instalA2 USCA.ind 15/4/09 2:35:39 PM 13 FINAL CHECKLIST Check all parts are installed. Ensure product is level, securely fastened to the cabinetry and opens and closes freely. The DishDrawer® must be free to fully close with no resistance from the cabinetry. Ensure inlet hose to water supply has rubber washer fitted and is tightened a further half turn after seal contact. Ensure any knockouts or plugs in drain connection have been drilled out and drain connection has been made. The drain hose joiner must not support the weight of excess hoses. Keep hoses as fully extended as possible to prevent sagging. Any excess length of hose should be kept on the DishDrawer® side of the high loop. If using Plumbing and Drainage OPTION A, ensure the Highloop is a minimum 6” (150 mm) higher than the drain hose joiner. Turn on the power and water supply. Then press the Power ( ) button to turn the DishDrawer® on. The DishDrawer® should beep and Wash Programme lights light up. Check the spray arm is in place and free to rotate. Spray arm Add three cups of water into the DishDrawer®. On the Wash Programme Selector Panel press Rinse and close the drawer. Start the programme by pressing the Start/Pause ( ) button. After the Rinse programme has finished, ensure machine has run and drained correctly. Check water supply and drainage connection for leakage. 14 TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle Check for kinked drain hoses or blocked waste connection, high loop not properly installed or drain hoses not routed correctly. No water supply ( shows on display-models with LCD only) Ch...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category