Login:
Votes - 2, Average rating: 4.5 ( )

User manual Jackson, model AJ-100CE

Manafacture: Jackson
File size: 9.55 mb
File name: 7610-002-30-93F_AJ-64_Series_part_1.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


See “Oil changing” below for additional information. Oil changing - When changing the oil for any reason, it should be remembered that oils of various types may not be compatible. Therefore, when changing to a different oil, it is recommended that the housing be completely drained and thoroughly flushed with a light flushing oil prior to refilling with the appropriate lubricant. The oil level should be rechecked after a short period of operation and adjusted, if necessary. When changing double reduction models, each housing should be drained and filled independently, even though there may be a common level. Initial oil change: The new oil in a speed reducer should be changed at the end of 250 hours of operation. This is equivalent to 30 days of peration for 8 hours per day; 15 days of operation for 16 hours per day, or 10 days of operation for 24 hours per day. Subsequent oil changes: Under normal conditions, after the initial oil change, the oil should be changed after every 2500 hours of operation, or every 6 months, whichever occurs first. Under severe conditions (rapid temperature changes, moist, dirty or corrosive environment) it may be necessary to mchange oil at intervals of one to three months. Periodic examination of oil samples taken from the unit will help establish the appropriate interval. Synthetic oils: Synthetic lubricants can be advantageous over mineral oils in that they generally are more stable, have a much longer life, and operate over a wider temperature range. These oils are appropriate for any application but are especially useful when units are subjected to low start-up temperatures or high operating temperatures. However, continuous operation above 225°F may cause damage to seals or other components. It is recommended that the initial oil be changed or filtered after the first 1500 hours of operation to remove metal particles that accumulate during break-in. Subsequent oil changes should be made after 5000 hours operation if units are operating in a clean environment. This can be extended to 10,000 hours if using new reformulated Mobil SHC lubricants (orange in color) and the lubricant remains free of contamination over this period. See comments under “Subsequent oil changes” for discussion of severe ambient conditions. Long term storage or infrequent operation: If a speed reducer is to stand idle for an extended period of time, either prior to installation or during use, it is recommended that the unit be filled completely with oil to protect interior parts from rust and corrosion due to internal condensation. Be sure to drain the oil to the proper level before placing the speed reducer in service. Grease fittings: Some units are equipped with grease fittings to lubricate bearings not adequately lubricated by the oil splash. These fittings must be lubricated every 3 - 6 months depending on operating conditions. bearing greases must be compatible with the type of gear lubricant being used (i.e. mineral, synthetic, food grade, etc.). For mineral oils, use a high quality lithium base NLGOI #2 bearing grease. For synthetic oils, use a synthetic bearing grease such as Mobil Synthetic Universal gease, Mobilith SHC 100 or a sutable equivalent. For food grade lubricants, use Chevron FM grease, NGLI 2, or equivalent. Low input speeds (under 1600 RPM): When input speeds are less than 1600 RPM, grease fittings will be required to lubricate any bearings not partially covered by the normal oil level. Oil temperature: Speed reducers in normal operation can generate temperatures up to 200°F depending on the type of reducer and the severity of the application 9loading, duration of service, ambient temperatures). Excessive oil temperatures may be the result of several factors including overloading, overfilling, underfilling or inadequate cooling. Nominal Ratio Size 5 7.5101520253040506080100 920 0.347 0.263 0.225 0.216 0.202 0.191 0.215 0.200 0.188 0.182 0.164 0.161 Lubricant selections are provided by the lubricant manufacturer based on AGMA recommeded viscosity grades. Viscosity grades are based on Lubrication Standard ANSI/AGMA 9005-D94. AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: N/A 48 SECTION 4: TROUBLESHOOTING SECTION 49 SECTION 4: TROUBLESHOOTING COMMON PROBLEMS WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service personnel. Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test equipment and reapply power to test. When replacing electrical parts, disconnect power at source circuit breaker. Problem: Nothing on dishmachine operates. The power switch is ON and the power indicator light is OFF. 1. Machine is not wired correctly to incoming power source. Have an electrician verify wiring. 2. Machine circuit breaker is tripped. Reset...

Other models in this manual:
Dishwashers - AJ-100CGP (9.55 mb)
Dishwashers - AJ-100CS (9.55 mb)
Dishwashers - AJ-64CE (9.55 mb)
Dishwashers - AJ-64CS (9.55 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category