max NETWORK AND COMMUNICATIONS (Optional -C24, -C4EI, -EI) Ethernet: Standards Compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS-232/RS-422/RS-485/MODBUS: Selectable from menu; both ASCII and modbus protocol selectable from menu. Programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status. RS-485 Addressable from 0 to 199 Connection Screw terminals ALARM 1 & 2 (programmable): Type Same as Output 1 & 2 Operation High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations ANALOG OUTPUT (programmable) Non-Isolated, Retransmission 0 to 10 Vdc or 0 to 20 mA, 500 . max (Output 1 only). Accuracy is + 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analog Output is not scaled below 3% of Output FS. 59 EXCITATION (optional in place of Communication) 24 Vdc @ 25 mA Not available for Low Power Option INSULATION Power to Input/Output 2300 Vac per 1 min. test 1500 Vac per 1 min. test (Low Voltage/Power Option) Power to Relays/SSR Outputs 2300 Vac per 1 min. test Relays/SSR to Relay/SSR Outputs 2300 Vac per 1 min. test RS-232/485 to Inputs/Outputs 500 Vac per 1 min. test Approvals FM, UL, C-UL, and see CE Approval Section GENERAL Line Voltage/Power 90-240 Vac +/-10%, 50-400 Hz* 110-375 Vdc, equivalent voltage 4 W, power for i8, i8C, i16, i32 Models 5 W, power for i8DV, i8DH, i16D Models * No CE compliance above 60 Hz Low Voltage/Power Option 12-36 Vdc, 3 W, power for i8, i16, i32 20-36 Vdc, 4 W, power for i8DV, i8DH, i16D External power source must meet Safety Agency Approvals. * Units can be powered safely with 24 Vac power but, no Certification for CE/UL are claimed. External Fuse Required Time-Delay, UL 248-14 listed: 100 mA/250 V 400 mA/250 V (Low Voltage/Power Option) Time-Lag, IEC 127-3 recognized: 100 mA/250 V 400 mA/250 V (Low Voltage/Power Option) Environmental Conditions • All models: 0 to 55°C (32 to 131°F), 90% RH non-condensing • i8DV, i8DH, i8C, i16D: 0 to 50°C (32 to122°F) for UL only. 90% RH non-condensing Protection NEMA-4x/Type 4x/IP65 front bezel: i32, i16D, i8C NEMA-1/Type 1 front bezel: i8, i8DH, i8DV Dimensions i/8 Series: 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5") i/8 Compact Series: 48 H x 96 W x 74 mm D (1.89 x 3.78 x 2.91") i/16 Series: 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5") i/32 Series: 25.4 H x 48 W x 127 mm D (1.0 x 1.89 x 5") Panel Cutout i/8 Series: 45 H x 92 mm W (1.772" x 3.622 "), 1/8 DIN i/16 Series: 45 mm (1.772") square, 1/16 DIN i/32 Series: 22.5 H x 45 mm W (0.886" x 1.772"), 1/32 DIN Weight i/8 Series: 295 g (0.65 lb) i/16 Series: 159 g (0.35 lb) i/32 Series: 127 g (0.28 lb) 60 Table 4.1 Input Properties TC Input Type Range Accuracy* J Iron-Constantan -210 to 760°C -346 to 1400°F 0.4°C 0.7°F K CHROMEGA®- ALOMEGA® -270 to -160°C -160 to 1372°C -454 to -256°F -256 to 2502°F 1.0°C 0.4°C 1.8°F 0.7°F T Copper-Constantan -270 to -190°C -190 to 400°C -454 to -310°F -310 to 752°F 1.0°C 0.4°C 1.8°F 0.7°F E CHROMEGA- Constantan -270 to -220°C -220 to 1000°C -454 to -364°F -364 to 1832°F 1.0°C 0.4°C 1.8°F 0.7°F R Pt/13%Rh-Pt -50 to 40°C 40 to 1788°C -58 to 104°F 104 to 3250°F 1.0°C 0.5°C 1.8°F 0.9°F S Pt/10%Rh-Pt -50 to 100°C 100 to 1768°C -58 to 212°F 212 to 3214°F 1.0°C 0.5°C 1.8°F 0.9°F B 30%Rh-Pt/ 6%Rh-Pt 200 to 640°C 640 to 1820°C 212 to 1184°F 1184 to 3308°F 1.0°C 0.5°C 1.8°F 0.9°F C 5%Re-W/ 26%Re-W 0 to 2354°C 32 to 4253°F 0.4°C 0.7°F N Nicrosil-Nisil -250 to -100°C -100 to 1300°C -418 to -148°F -148 to 2372°F 1.0°C 0.4°C 1.8°F 0.7°F L J DIN -200 to 900°C -328 to 1652°F 0.4°C 0.7°F RTD Pt, 0.00385, 100 ., 500 ., 1000 . 200 to 900°C -328 to 1652°F 0.4°C 0.7°F RTD Pt, 0.00392, 100 ., 500 ., 1000 . -200 to 850°C -328 to 1562°F 0.4°C 0.7°F PROCESS Voltage 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc 0.03% rdg 0.03% rdg PROCESS Current 0 to 20 mA, 4 to 20 mA 0.03% rdg 61 PART 5 FACTORY PRESET VALUES Table 5.1 Factory preset value MENU ITEMS FACTORY PRESET VALUES NOTES Set Point 1 (SP1) 000.0 Set Point 2 (SP2) 000.0 Input: Input Type (INPT) TC, type K Reading Configuration (RDG): Decimal Point (DEC.P) FFF.F Temperature unit (TEMP) °F Filter value (FLTR) 0004 Alarm 1 & 2: Alarm 1 (ALR1), Alarm 2 (ALR2) Disable (DSBL) Absolute/Deviation (ABSO/DEV) Absolute (ABSO) Latch/Unlatch (LTCH/UNLT) Unlatch (UNLT) Contact Closure (CT.CL) Normally Open (N.O.) Active (ACTV) Above (ABOV) Alarm At Power On (A.P.ON) Disable (DSBL) Alarm 1 only Alarm Low (ALR.L) -100.0 Alarm High (ALR.H) 400.0 LOOP: Loop Break Time (LOOP) Disable (DSBL) Loop Value (B.TIM) 00:59 Reading Adjust Value (R.ADJ) 000.0 Setpoint Deviation (SP.dV) Disable (DSBL) ANALOG OUTPUT (Retransmission): Analog Output (ANLG) Enabled (ENBL) Current/Voltage (CURR/VOLT) Voltage (VOLT) Scale and Offset Reading: 0 - 999.9 cts, Output: 0 - 10 V OUTPUT 1 & 2: Self (SELF) Disabled (DSBL) Output 1 only % Low Value (...

Other models in this manual:
Weather Radios - CNI8 (1.2 mb)
Weather Radios - CNI8C (1.2 mb)
Weather Radios - CNI8DH (1.2 mb)
Weather Radios - CNI8DV (1.2 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category