Login:
Votes - 4, Average rating: 3.5 ( )

User manual Broan, model HEPA 2000

Manafacture: Broan
File size: 4.67 mb
File name: 9872dc9f-61b4-4aa0-8385-b440f3f2fe64.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Do not remove the ground prong. Do not use an extension cord. 9. Do not install in a cooking area or connect directly to any appliances. 10. Do not use to exhaust hazardous or explosive materials and vapors. CAUTION 1. To avoid prematurate clogged filters, turn OFF the unit during construction or renovation. 2. Please read specification label on product for further information and requirements. 3. For HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 units only: Be sure to duct air outside – Do not intake / exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage. 4. Itended for residential installation only in accordance with the requirements of NFPA 90B. 5. Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing appliance. For HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 units only, if a duct has to be connected to the furnace return plenum, it must be connected not closer than 9’10” (3 m) from this plenum connection to the furnace. For HEPA 1000 and HF 1.0 units only, the distance must be not closer than 2’ (0.61 m). 6. The ductwork is intended to be installed in compliance with all local and national codes that are applicable. - 3 TABLE OF CONTENTS 1.0 BEFORE STARTING . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 1.1 Inspect the Content of the Boxes . . . . . . . . . . .. . 6 2.0 TYPICAL INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . .6 2.1 HEPA 1000 and HF 1.0 Unit Installations . . . . . . 7 2.1.1 Stand Alone . . . . . . . . . . . . . . . . . . . . . . . . ..7 2.1.2 Central Draw Point . . . . . . . . . . . . . . . . . . . ..8 2.1.3 Return-to-Return Installation . . . . . . . . . . . . . . . .9 2.2 Installations for HEPA 4000 Only . . . . . . . . . . . .10 2.2.1 Geographical Location . . . . . . . . . . . . . . . ..10 2.2.2 HEPA 4000 Attic Installation . . . . . . . . . . . . ..11 2.3 HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 Unit Installations . . . . . . . . . . . .12 2.3.1 Stand Alone . . . . . . . . . . . . . . . . . . . . . . . ..12 2.3.2 Central Draw Point . . . . . . . . . . . . . . . . . . ..13 2.3.3 Return-to-Return Installation . . . . . . . . . . . . . . .14 3.0 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 3.1 HEPA 1000 and HF 1.0 Units . . . . . . . . . . . . ..15 3.2 HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA4000 units . . . . . . . . . . . . . . . . . . ..15 3.3 Mounting and Servicing Considerations . . . . . . . .16 4.0 INSTALLTHE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . .17 4.1 Locating and Mounting the Unit . . . . . . . . . . . ..17 4.2 Mount the Ports on the Unit . . . . . . . . . . . . . . ..17 4.3 How to Hang the Unit . . . . . . . . . . . . . . . . . ..18 4.4 Planning of the Ductwork . . . . . . . . . . . . . . . ..19 4.5 Installing Ductwork and Registers . . . . . . . . . . . .20 4.5.1 Stand Alone System . . . . . . . . . . . . . . . . . ..20 4.5.2 Central Draw Point . . . . . . . . . . . . . . . . . . ..21 4.5.3 Return-to-Return . . . . . . . . . . . . . . . . . . . . ..22 - 4 TABLE DES MATIERES 4.6 Installation des conduit flexibles . . . . . . . . .23 4.6.1 Raccordement a la transition . . . . . .23 4.6.2 Raccordement aux . .24 4.7 Installation de la bouche . . . . . .25 4.7.1 Assemblage de la . . .25 4.7.2 Localisation de la bouche . . .25 4.7.3 Raccordement de la transition a la bouche exterieure double . . . . . . . . . . ..25 4.8 Raccordement du boyau de . . . . . . . . .27 5.0 CONTROLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 5.1 Interrupteur principal . . . . . . . . . . ..28 5.2 Controle muraux optionnels . . . . . . . . . . .. 5.3 Dimensions . . . . . . . . . . ..28 5.4 Installation des controles . . . . .29 5.5 Fonctionnement du controle . . . . . . . .32 5.5.1 Description du controle C12 . . . . . . . . .32 5.5.2 Utilisation du controle C12 / . . . . . . . . . .32 5.6 Fonctionnement du controle . . . . . . .33 5.6.1 Description du controle C34/ . . . . . . . .33 5.6.2 Utilisation du controle C34 . . . . . . . . .33 6.0 ENTRETIEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 6.1 Entretien semestriel . . . . . . . . . . ..34 6.2 Entretien annuel . . . . . . . . . . ..36 6.3 Reinitialisation .. 7.0 PIECESDESERVICE . . . . . . . . . . . . . . . . . . . . . . . . . .37 8.0 DEPANNAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 - 5 1. BEFORE STARTING 1.1 INSPECT THE CONTENTS OF THE BOXES WARNING To avoid risk of suffocation, discard the plastic bag wrapping the unit. 0 ! • Inspect the exterior of the unit for shipping damage. Ensure that there is no damage to the door, door latches, main switch, etc. CAUTION Remove the cardboard strip inside the unit (if applicable). • Inspect the interior of the unit for damage. Ensure that blower assembly, heat recovery core (HEPA 3000 et HF 3.0), energy recovery core (HEPA 4000), in...

Other models in this manual:
Kitchen-ranges - HEPA 1000 (4.67 mb)
Kitchen-ranges - HEPA 3000 (4.67 mb)
Kitchen-ranges - HEPA 4000 (4.67 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category