Login:
Votes - 3, Average rating: 4.3 ( )

User manual Indesit, model DX

Manafacture: Indesit
File size: 1.35 mb
File name:
Language of manual:ruitenesfrdenlpt
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


Connect the wires in accordance with the instructions given in the following table and diagrams: Voltage and Electrical cable Wire connection mains frequency : yellow/green 220-240V 1+N ~ N: the two blue wires together 50/60 Hz L: brown and black together Other types of connection If the mains supply corresponds with one of the following: Voltage and mains frequency • 400V - 2+N ~ 50/60 Hz • 220-240V 3 ~ 50/60 Hz • 400V - 2+2N ~ 50/60 Hz Separate the wires and connect them in accordance with the instructions given in the following table and diagrams: Voltage and mains frequency Electrical cable Wire connection 400V - 2+N ~ : yellow/green; 50/60 Hz N: the two blue wires 220-240V 3 ~ together 50/60 HzL1: black L2: brown : yellow/green; 400V - 2+2N ~ 50/60 HzN1: blue N2: blue L1: black L2: brown If the mains supply corresponds with one of the following: Voltage and mains frequency • 400V 3 - N ~ 50/60 Hz proceed as follows: ! The cable provided is not suitable for the following types of installation. 1. Use a suitable supply cable, H05RR-F or higher, with the right dimensions (cable cross section: 25 mm). 2. To open the terminal board, use a screwdriver as a lever under the side tabs of the cover (see Terminal board picture). 3. Loosen the cable clamp screw and the terminal board screws in accordance with the type of connection required and position the connection supports as shown in the following table and diagrams. GB 19 GB GB 4. Position the wires in accordance with the information given in the following table and diagrams and connect the appliance by tightening all the screws for the springs as much as possible. Voltage and Electrical connections Terminal board mains frequency 400V 3-N ~ Three-phase 400 50/60 Hz 5. Secure the power supply cable by fastening the cable clamp screw, then put the cover back on. 51 2 3 4 Three-phase 400 Phase Phase Phase Neutral Earth connection support U-bolt Connecting the electricity supply cable to the mains If the appliance is being connected directly to the electricity mains an omnipolar switch must be installed with a minimum opening of 3 mm between contacts. ! The installer must ensure that the correct electrical connection has been made and that it is fully compliant with safety regulations. Before connecting the appliance to the power supply, make sure that: • The appliance is earthed and the plug is compliant with the law. • The socket can withstand the maximum power of the appliance, which is indicated on the data plate located on the appliance itself. • The voltage falls within the range of values indicated on the data plate. • The socket is compatible with the plug of the appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. ! The cable must not be bent or compressed. ! The cable must be checked...

Other models in this manual:
Kitchen-ranges - C (1.35 mb)
Kitchen-ranges - X (1.35 mb)
Kitchen-ranges - VRM 641DC (1.35 mb)
Kitchen-ranges - VRM 630C (1.35 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category