Login:
Votes - 2, Average rating: 4.5 ( )

User manual Angelcare Monitors, model BEBESOUNDS AC201

Manafacture: Angelcare Monitors
File size: 2.15 mb
File name:
Language of manual:svenesfrdenldafi
Free link for this manual available at the bottom of the page



manual abstract


These signals do not present a safety hazard. • Your monitor can be used in any crib or sleeping area (that has no motion or vibration) designed to safely hold a baby. It must have a firm flat bottom greater than the size of the Sensor Pad - 260 mm x 406 mm (10" x 16"). DO NOT use in a rocking cradle. • If you have questions or need help, please call your distributor, see page 43. Warnings • This product is NOT a medical device nor a device to prevent cases of Sudden Infant Death Syndrome • This product is NOT a substitute for direct supervision of your baby. Check your baby’s activities at regular intervals. Monitoring of premature babies, or those considered to be carried out only under the supervision of a doctor or health professional. • The Sensor Pad may detect movement from many sources from both inside and outside your baby’s room, for example: fans, washing machines, loud music, etc. Ensure that all vibration sources are eliminated before using the Angelcare ® Monitor. Avoid contact with crib when monitor is in use. Refer to the Movement Sensitivity Adjustment and Troubleshooting sections. • ALWAYS place both units on flat surface in an upright position, away from baby’s reach. • DO NOT touch the end of the adapter cord when plugged into an electrical outlet. • The Angelcare ® Monitor uses public airwaves to transmit signals. The Parents Unit may pick up signals or interference from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are in the OFF position when not in use. • This product should be serviced by qualified personnel. There are no user serviceable parts inside monitor. Refer all service questions to your distributor (see page 43). Instructions RETAIN INSTRUCTIONS: Keep user’s manual for future reference. WATER, MOISTURE AND HEAT DAMAGE: Keep all 3 components away from water (sink, bath tub, swimming pool) and places that emit heat (stove, radiator). VENTILATION: ALWAYS place both units on flat surface in an upright position so that air can flow freely around them. AC POWER SOURCE: Use ONLY the AC adapters supplied with the Angelcare ® Monitor. CORD PROTECTION: Avoid damage to the Sensor Pad cord and to the adapter cords. Route cords so that they are not likely to be walked on or pinched by items placed upon or against them. CLEANING: Disconnect all units before cleaning. DO NOT immerse in water. Use a dry cloth to keep monitor free from dust. DO NOT spray with cleaning products or solvents. Wipe Sensor Pad with a very slightly damp cloth with an antiseptic or mild detergent. OBJECT AND LIQUID ENTRY: Care should be taken so that objects do not fall onto units and that liquids are not spilled into either unit or Sensor Pad through their openings. NON-USE PERIODS: When not using monitor for long periods, remove the batteries from both units and disconnect the AC adapters from electrical outlet. Testing Your Angelcare ® Monitor Note: Test your Angelcare ® Monitor BEFORE first-time use and then on a periodic basis. The Angelcare ® Monitor can be used outside of the crib, in a different sleeping area. Test monitor when moving Sensor Pad to a new location to ensure sensitivity is adjusted correctly to the new padding or mattress. Consult the Movement Sensitivity Adjustment section. Step 1. On the Nursery Unit, switch to the "Sound Only" function. Have someone else speak into the Nursery Unit or place a radio near Nursery Unit. You should hear sound from the Parents Unit. If there is no sound, refer to the Troubleshooting section. Make sure that both units are on the same channel, isnot clear, switch to other channel. Step 2. Test monitor to detect movement. Switch Unit to the "Sound & Movement" function. The Movement red, green and then emit a single "Tic" sound. Gently pat your hand on the mattress. The green light will continue to movement. Remove hand from mattress. Due Tic" sound will emit after 15 seconds. 5 seconds later, the alarm will sound and the red light will flash continuously. NOTE: If alarm does not sound, the Sensor Pad may be detecting continuous vibration from the floor, a strong draft or the crib is being touched. Avoid contact with crib when monitor is in use. Place crib near a solid supporting wall and away from strong air currents. sensitivity of the Sensor Pad may need to be reduced, consult the Movement Sensitivity Adjustment section. Step 3. To stop alarm, pat your hand lightly on mattress for Sensor Pad to redetect movement. The red Alarm indicator light on the Nursery Unit will continue to flash 1 minute (Figure 3). Step 4. Verify that the battery mode is functional by operating both units without the AC adapters. The green Power light should appear on both units. Parents Unit: When orange Low Battery indicator light appears, replace batteries promptly for Model AC201. For Model AC201-R, recharge Parents Unit. Nursery Unit: When orange Low Battery indicator light appears a rapid "...

Other models in this manual:
Kitchen-ranges - BEBESOUNDS AC201-R (2.15 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category