The throat plate should be removed and checked monthly, and any debris stripped off. Similarly, clean the upper surface of the firebox. Refer to page 16 for instructions on the throat plate removal / inspections. OUTER FINISH The outside finish of the appliance is a durable high temperature paint. It is best cleaned by brushing down with a clean shoe brush. Do not allow moisture to remain on the appliance whilst cold or surface rust may form. The high temperature paint should not require attention for some time, depending on use. The hotter the fire burns the sooner repainting will be necessary. Aerosol tins of paint are available for complete refurbishing. Before repainting make sure that the fire is out and is cold. •Remove the door glass. •Lightly wire brush, or rub with wire wool, the body of the appliance to remove any loose paint powder. •Mask or remove items such as brass work. •Any adjacent brickwork, mantelpiece, hearth, etc., should be carefully masked for quite a distance around the appliance. (this precaution is to prevent discolouration of the surrounding brick work, wallpaper etc). Re-spray in a well-ventilated area - avoid breathing the vapour. Refer to safety instructions on paint cans. •When the paint is dry refit door glass and any other parts previously removed. •Leave the appliance for eight hours before re-lighting. •Burn slowly for the first four hours, then build up heat gradually to cure the paint. Note: Use only genuine Aarrow Fires touch-up spray as some paints interact. This could ruin the finish and invalidate the guarantee. DOOR GLASS The door glass should remain clear during normal daytime burning. However under certain conditions-such as burning at a low rate with damp wood, or overnight burning, the glass may become somewhat blackened. To remedy this, operate the appliance at a fast rate. Alternatively when the stove is cold open the door and clean the inside face of the glass with a damp cloth or with glass cleaner (available from fire stockists). Apiece of cloth moistened with vinegar and dipped in wood ash -not coal ash - will provide a good soft scourer to remove the soot without scratching the glass. CHIMNEY SWEEPING Sweeping should be carried out with an appropriate sized bristle brush and rods to suit chimney size and type. As with all appliances regular sweeping of the flue is essential to avoid the danger of blockage and the escape of poisonous fumes. Access for cleaning should also be incorporated in the chimney (e.g. soot door or access through register plate). Any existing chimney should be swept prior to installation of the appliance, and swept again a second time within one month of regular use after installation to establish frequency of sweeping required. This should be done by a competent person such as a NACS chimney engineer who will provide a Certificate of Chimney Sweeping. Sweep the whole flue way, including the outlet, at least twice per burning season. It is important that the flue ways, flue pipe and chimney be cleaned prior to lighting the fire after a prolonged shut-down period. If any damage or doubt over the flue or chimney exists, DO NOT use the appliance until the chimney and connector have been inspected and any damaged parts repaired or replaced. This should be done by a competent person such as a HETAS registered engineer. Aarrow Ecoburn Wood & Multifuel Stoves SERVICE & MAINTENANCE ANNUAL MAINTENANCE It is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following. Remove the fire lining(s), and throat plate, inspect all gasketing on doors, glass etc. and re-order any items that may need replacing, from your Aarrow dealer. With a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside of the stove, above the fire door. Ensure the inside face of the fire door is free of debris around the area of the primary air inlet. Sweep the chimney and confirm that it is sound. Examine all joints in the flue pipe etc. and re-seal if necessary. SUMMER STORAGE/NON USAGE Please ensure that your stove is left clean and moving components are well lubricated for the summer months (during periods of prolonged non use). If possible store the throat plate outside of the stove, check all movable components, at regular intervals, to ensure they are moving freely. Allow air movement through the stove, by opening the airwash and prinmary air inlet(s) controls to about half way open or leave the door ajar. This will allow a free flow of air through the appliance thus preventing moisture and condensation forming inside the stove and chimney. This preventative maintenance will ensure your stove stays in the best condition for the coming winter months. DOOR ADJUSTMENT Once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignmen...

Other models in this manual:
Kitchen-ranges - EcoBurn AFS1221 (2.1 mb)
Kitchen-ranges - EcoBurn AFS1221 (2.1 mb)
Kitchen-ranges - EcoBurn BK043 (2.1 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category