Login:
Votes - 3, Average rating: 3.7 ( )

User manual Carrier, model 48KHA

Manafacture: Carrier
File size: 1.76 mb
File name: 48kh,kl-19si.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Consult a qualified installer, service agency or the gas supplier for information or assistance. NOTE: Installation of this unit must conform to the guidelines presented in these Installation Instructions. Read and become familiar with this publication before starting installation. Only trained, qualified installers and service mechanics should install, start-up and service this equipment. Consult the User’s Manual for routine maintenance. All other operations should be performed by trained service personnel, personnel. • Follow all safety codes. • Wear safety glasses and work gloves. • Use care in handling, rigging and setting bulky equipment. • Observe precautions in these instructions and on equipment tags, stickers and labels. A WARNING Do not disconnect electric power to this appliance without first turning off gas supply. Be sure power to equipment is shut off before maintenance or service. Fig. 1—Model 48KHA,KLA GENERAL Models 48KHA,KLA packaged gas/electric units (Fig. 1) are design certified in accordance with ANSI Z21.47B-1986, ARI Standard 210-81 and ARI Standard 270-84. The units are design certified by the American Gas Association (AGA) for use with natural or propane gases with appropriate controls or orifices. See Table 1 for heating input ratings. Models 48KHA.KLA units are fully self-contained, combination gas-heating/electric-cooling units designed for outdoor installation on either a rooftop or ground-level slab. May be installed directly on wood flooring or on Class A, Class B or Class C roof covering materials. These units are equipped with an energy-saving automatic, intermittent, electric spark ignition system that does not have a continuously burning pilot. All units are manufactured with natural gas controls. Units with number 1 in the 4th digit location of model number in Table 1 meet California oxides of nitrogen (NOx) maximum emission requirements. Units are factory charged with R-22 refrigerant. To install: connect gas supply, air ducts, high- and low-voltage wiring and condensate drain, and install a field-supplied air filter in the return-air ductwork. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Bookl 1 I 4 PC 101 Catalog No 534-862 Printed In USA Form 48KH.KL-19SI Pg 1 1-88 Replaces: 48KH.KL-17SI Tab 11a 11a For replacement items contact distributor. Table 1 —Performance Data MODEL 48- COOLING CAPACITY (Btuh)* RATED HEATING INPUT (Btuh) OUTPUT CAPACITY (Btuh) ARI* SOUND RATING (Bels) KLA118310BE 17,800 40,000 32,000 7.8 KLA124310BE 23,800 40,000 32,000 7.8 KHA024310BF 24,000 75,000 58,000 8.0 KLA130310BE 29,600 40,000 32,000 7.8 KHA030310BF 29,600 75,000 58,000 7.8 KLA136310BE 36,000 60,000 47,000 8.0 KLA136510CE 36,000 60,000 45,000 8.0 KLA136610CE 36,000 60,000 45,000 8.0 KHA136310BE 36,000 100,000 79,000 8.0 KHA136S10CE 36,000 100,000 75,000 8.0 KHA036310BF 36,000 125,000 97,000 8.0 KHA036510CF 36,000 125,000 93,750 8.0 KLA142310BE 42,000 60,000 47,000 78 KLA142510CE 42,000 60,000 45,000 7.8 KHA042310BF 42,000 125,000 97,000 7.8 KHA042510CF 42,000 _125,000 93,750 7.8 KLA148310BE 49,000 80,000 63,000 8.4* KLA148510CE 49,000 80,000 60,000 8.4* KLA148610CE 49,000 80,000 60,000 8.4* KHA048310BE 49,000 125,000 97,000 8.4* KHA048510CF 49,000 125,000 93,750 8.4* KLA160310BE 60,000 100,000* 79,000* 8.4* KHA060310BF 60,000 150,000* 116,000* 8.4* ♦Rated in accordance with U S. Government D.O.E. test procedures and/ or ARI Standard 210-81. tSound rating per ARI 270-84. *The capacity ratings of single-phase units are in accordance with U.S. Government D.O.E. test procedures and/or AGA certification requirements. For 3-phase units, the efficiency rating is a product thermal efficiency rating determined under continuous operating conditions, independent of any installed system. All units can be connected into existing duct systems that are properly sized and designed to handle an airflow of 350 to 450 cfm per each 12,000 Btuh of rated cooling capacity. See Table 8 for cooling and heating airflow requirements. NOTE: When installing any accessory item, see Installation Instructions packaged with accessory. IMPORTANT-READ BEFORE INSTALLING 1. This installation must conform with all applicable local and national codes. 2. Power supply (volts, hertz and phase) must correspond to that specified on unit rating plate. 3. Electrical supply provided by utility must be sufficient to handle load imposed by unit. 4. Refer to Fig. 4 for locations of gas inlet, electrical inlets, condensate drain, duct connections, and required clearances before setting unit in place. 5. Locate unit where vent cap will be a minimum of 4 ft from openable windows or doors. 6. Installation must conform with local building codes and with National Fuel Gas Code, NFPA 54-1984/ ANSI Z223.1-1984. IMPORTANT: On some models, the high-voltage ignition cable is not connected t...

Other models in this manual:
Kitchen-ranges - KLA (1.76 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category