Login:
Votes - , Average rating: ( )

User manual Desa Tech, model CSNPT

Manafacture: Desa Tech
File size: 2.86 mb
File name: b13d1cbc-a61d-36a4-21f4-1200656436bd.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 1. STOP! Read the safety information, abovc. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 16, page 12). LIGHTING INSTRUCTIONS NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open a window to vent smell. This will only last a few hours. INSTALLATION Installing Log Set OPERATING HEATER For Your Safety Read Before Lighting Lighting Instructions LO PILOT OFFHI Figure 14 - Installing One-Piece Stove Log Set Burner Porting Areas (double slotted rectangular openings Figure 15 - Top View of One-Piece Log Set on Gas Log Heater Safety Pilot Location One-Piece Log Set One-Piece Log Set Heater Base "U" Shaped Cutout in Chassis Burner Middle Section at Bottom of Log Set INSTALLING LOG SET 1. Set one-piece log on heater base as shown in Figure 12. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 14). 2. Fasten back panel to stove with four (4) bolts and washers removed in step 4 of Unpacking, page 6. Make sure product identification label is located on the outside lower left-hand corner. 3. Place freestanding stove in desired position being careful not to damage gas connections. Be sure to maintain clearances to combustibles and wall clearances as outlined on page 7. INSTALLATION Continued 12 12 OPERATING HEATER Lighting Instructions (Cont.) To Turn Off Gas To Appliance Thermostat Control Operation Manual Lighting Procedure INSPECTING BURNERS OPERATING HEATER Continued Note:You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note:If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, column 2. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note:If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO. Control KnobIgnitor Button CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. Figure 16 - Control Knob and Ignitor Button Location Pilot Burner Thermocouple Figure 17 - Pilot TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise to the PILOT position. THERMOSTAT CONTROL OPERATION The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. Note:Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases. 1. Follow steps 1 through 5 under Lighting Instructions, page 11. MANUAL LIGHTING PROCEDURE 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in Lighting Instructions, column 1. INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 18 sho...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category