Manafacture: Elation Professional
File size: 673.47 kb
File name: profs-575.pdf
|
manual abstract
Please read the following instructions before installing and using your new unit. Operating Instructions: The Pro FS 575 features a bright ZB-MSR575 575 watt lamp, full focusing knob located on the top as well as zoom control, control levers at the top of the unit for iris adjustment, and built- in individual gel frames. Notice: When the unit is brand new, smoke will emit from the inside of unit. This is the paint on the inside burning off. There is no problem with the unit, this is normal. To replace lamp; Unscrew the two thumb screws located at the rear of the unit, slide out the lamp assembly, replace bulb and reassemble. Do not forget to unplug unit before replacing bulb! The Breaker is located at the rear of the unit. For service, contact your Elation dealer. Caution! Always disconnect from main power before replacing lamps or servicing unit. Remember to always replace with same type of lamp. CAUTION! WARNING! The top of unit gets extremely hot, watch where you rest your hands, or objects that can melt or burn. Discharge Lamp Warning: This fixture is fitted with a discharge lamp which is highly susceptible to damage if improperly handled. Never touch the lamp with your bare fingers as the oil from your hands will shorten lamp life. Also, never move the fixture until the lamps have had ample time to cool. Remember, lamps are not covered under warranty conditions. This unit emits intense UV radiation which is harmful to the eyes and skin. The intense luminance of the lamp can cause severe damage to the retina. Never operate this unit without it’s covers, these covers have been specially designed to shield against UV radiation. Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the lamp at all times. Avoid switching the fixture on and off repeatedly in short intervals as this will reduce lamp life and intensity. To achieve the intensity associated with discharge lamps, these lamps use gas sealed in a high pressure environment to emit a brilliant output. Due to the high pressure involved with the construction of the lamp, the lamp may explode during prolonged extensive use. This risk is increased with age, added care is encouraged when dealing with older lamps. Extreme caution should be used when operating this or any fixture fitted with a gas discharge lamp. Never open this unit while in use. Model: Pro FS 575 SPECIFICATIONS: Lamp: ZB-MSR575 575W Power: 120V/60Hz ~ 230V/50Hz Breaker : 15 Amp Ventilation: Fan Cooling Working Position: Any Weight: 50.75 lbs./ 23Kgs Size: 27.5” x 10” x 6.75” Customer Support: ©Elation® provides a customer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at elationlighting.com for any comments or suggestions. Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time. Voice: (323) 582-3322 Fax: (323) 832-9142 E-mail: support@elationlighting.com Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ©Elation®. 2-YEAR LIMITED WARRANTY A. Elation Professionals® hereby warrants, to the original purchaser, Elation Professionals® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professionals® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professionals® will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professionals® shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which Elation Professionals® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professionals® factory unless prior written authorization was issued to purchaser by Elation Professionals®; if the product is damaged because not properly maintained as set forth in the i...