User manual Crestron electronic, model 2 Channel Dimmer Module CLX-2DIM2
Manafacture: Crestron electronic File size: 437.93 kb File name: clx-2dim2.pdf
Language of manual:
|
|
|
|
Free link for this manual available at the bottom of the page
manual abstract
Each channel is rated for 1920 Watts, with a total module rating of 3840 Watts when fed from two separate 20 Amp feeds. Air-gap relays are provided on each channel output allowing an individual circuit to be serviced without disabling the entire module. CLX-Series dimmers are rigorously built using 40 Amp triacs and oversized heat sinks for ultimate reliability. Split-bobbin transformers and ground referenced electronics deliver superior performance. Lamp flicker is minimized through Crestron’s innovative zero-crossing detection technique backed by proprietary firmware. Low-maintenance convection cooling assures quiet and trouble-free operation. An override feature allows each channel to be adjusted to a preset state during setup. In the event that Cresnet communications should be disrupted for any reason, a simple contact closure can be used to activate the override presets on a global or semi-global basis. The CLX-2DIM2 occupies a single module space in any CAEN automation enclosure. Termination of high-voltage wiring to the module is facilitated by a CLT-2DIM2 terminal block, sold separately to enable termination of the wiring anytime prior to installing the module. CLX modules are controlled by the PAC2 and PAC2M professional automation control systems via the Cresnet network. A 5-wire link provides bussing of the Cresnet and override signals between modules within an enclosure (interconnect jumpers included). SPECIFICATIONS Load Ratings_ Dimmer Channels: 2 Per Channel: 16 Amps (1920 Watts) Module Total: 32 Amps (3840 Watts) Load Types: Incandescent, Magnetic Low-voltage, Neon/Cold Cathode, Dimmable 2-Wire Fluorescent Power Requirements_ 120 Volts AC, 60Hz, single-phase All feeds must be same phase or split phase Shown with CLT-2DIM2 Terminal Block Connections on module Module Interconnect: (2) 5-pin 0.156 inch headers, Cresnet/Override interconnect ports Connect to PAC2, PAC2M, CAEN-BLOCK, or adjacent CLX-Series module using interconnect cable provided Connections via CLT terminal block (sold separately)_ LINE 1 - 2: (2) DIN rail terminal blocks, black, line power inputs Must be same phase or split phase DIM 1 - 2: (2) DIN rail terminal blocks, red, channel outputs N IN 1 - 2: (2) DIN rail terminal blocks, white, line input neutrals N OUT 1 - 2: (2) DIN rail terminal blocks, white, channel output neutrals Buttons_ SETUP: Used for manual channel activation and TSID LED Indicators_ PWR: (green) Indicates line power is applied to the LINE terminal NET: (yellow) Indicates communication with the control system 1 - 2: (red x2) Indicates state of each channel SETUP: (red) Indicates unit is in setup/manual mode Environmental_ Temperature: 32° to 104°F (0° to 40°C) Humidity: 10% to 90% RH (non-condensing) Heat Dissipation: 20 BTU/Hr + (4.7 BTU/Hr x Load Current in Amps), 170 BTU/Hr at maximum load Enclosure_ Gray metal with black heat sink, surface mount module with (2) integral mounting flanges, occupies 1 module space in any CAEN enclosure Dimensions Height: 7.59 In (19.27 cm) Width: 6.92 In (17.57 cm) Depth: 3.43 In (8.70 cm) Weight_ 3.00 lb (1.36 kg) AVAILABLE ACCESSORIES CAEN Automation Enclosures CLT-2DIM2 Terminal Block CLX-2IND 2 Channel Inductor Module CLX-4IND 4 Channel Inductor Module Crestron Electronics, Inc. 15 Volvo Drive l Rockleigh, NJ 07647 Tel: 800.237.2041 /201.767.3400 l Fax:201.767.1903 Specifications subject to change without notice. Doc.4845 Î2/07 ©2007 Crestron Electronics, Inc. All brand names, product names and trademarks are the property of their respective owners. | 800.237.2041...
|