Login:
Votes - 1, Average rating: 5 ( )

User manual Bionaire, model ULTRASONIC Humidifier BU5100

Manafacture: Bionaire
File size: 1.4 mb
File name: 34187b08-b176-4995-a42d-c0bfa6bdad95.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


WARNING: DO NOT move the humidifier with water in the tank or the humidifier base. The moving action of the water may activate the water tank’s release nozzle and overfill the humidifier base. This may cause the humidifier to function intermittently, or stop emitting mist. Should this occur, simply remove the excess water from the humidifier base. IMPORTANT: If you do not plan to use your humidifier for two or more days, make sure any residual water is drained from the water tank and base to prevent any algae or bacteria growth in stagnant water. Make sure the tank is dry. CLEANING AND MAINTENANCE INSTRUCTIONS Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use. In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the humidifier's tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. DAILY MAINTENANCE 1. Be sure the unit is OFF and is disconnected from the electrical outlet 2. Remove the tank from the humidifier and place in sink or tub. 3. Drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean and dry with a clean cloth or paper towel. 4. Refill with cool tap water. Do not overfill. WEEKLY MAINTENANCE To Remove Scale: 1. Repeat steps 1-3 above. 2. Clean the base by partially filling Figure 2 it with one 8-oz cups of undiluted white vinegar or by using Cleanse CleanTM Solution (DMS216) by the manufacturer. Leave this solution in the tank for 20 minutes, while cleaning all interior surfaces with a soft brush. Gently scrub the area around the transducer with a soft brush. Remove the scale by wiping the entire base with a cloth dampened with undiluted white vinegar. 3. Rinse clean with warm water to remove cleaning solution before disinfecting the tank. To Disinfect Tank 1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Carefully empty the tank after 20 minutes, and rinse with warm water until you can not detect any bleach smell. Dry with a clean cloth or paper towel. 4. Refill the water tank as directed in Operating Instructions, and turn the unit on. FREQUENTLY ASKED QUESTIONS QUESTIONS ANSWER • What are the The estimated run time for this variables that humidifier is based on average room affect run time? conditions. The actual run time of your humidifier is dependent on numerous variables such as: 1. Air exchange in the room where the humidifier is placed. 2. Room construction where the humidifier is placed. 3. Temperature of the room where the humidifier is placed. 4. Humidity levels in the room where the humidifier is placed. 5. Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. 6. Home furnishings in the room where the humidifier is placed. • How do I remove film on water tank? See Daily Maintenance instructions. Regular cleaning is recommended. • How can I 1. Run your unit on the lowest setting. extend the (not applicable to BU5200) run time? 2. Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time. 56 8 3. This humidifier is equipped with an agency required overflow feature. To prevent spillage or overflow of water, avoid tilting the humidifier while carrying. Should your humidifier require service, please call 1-800-253-2764 in North America for further assistance. 7 STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time: 1. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season. 2. Place the humidifier in the original carton and store in a cool, dry place. REPLACEMENT ACCESSORIES To order the replacement accessories you can do any of the following: • Visit your local retailer • Go to • Call consumer service at 1-800-253-2764 SERVICE INSTRUCTIONS 1. Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The inside of humidifier contains no user serviceable parts. All servicing should be performed by qualified personnel only. 2. If you need to exchange the unit, please return it in its original carton, with a sales receipt, to the store where you purchased it. If you are returning the...

Other models in this manual:
Dehumidifiers - ULTRASONIC Humidifier BU5200 (1.4 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category