Manafacture: Dri-Eaz
File size: 113.41 kb
File name: c6cefb62-cf3b-42ad-bae7-abe414a2c4b2.pdf
|
manual abstract
Do not pour or run water onto the unit or allow water to soak the touchpad control. Bring back the original shine with a vinyl cleaner-polish. Periodic Maintenance (as needed) Make sure unit is unplugged. Remove housing as needed to permit access to interior parts. KEEP COILS CLEAN. Dirty coils do not remove water efficiently. Inspect them regularly, especially if operating in dusty environments. Clean if they are visibly dirty. First make sure coils are dry, then blow them clean with direct compressed air from both sides of the coil. Do NOT hold too close to the coils, as high-pressure air may fold the fins. If sticky or oily residue remain, do a wet cleaning. Use a squirt bottle to flush the coil with water and a little detergent. Do NOT run a hose or pressure washer on the coils, or permit water to enter the electrical compartment. Remove dirt buildup with an aluminum evaporator coil cleaner available from a refrigeration supply outlet. Follow product directions carefully. When cleaning coils, also make sure that the drain tray, drain hose, and filter cover are free of dirt. PUMP SYSTEM: Inspect and clean the pump system regularly to maintain effective operation. Remove the four screws holding down the pump cover. Clean the catch basin. Make sure the float shaft operates smoothly and does not stick in the OFF position. Use a pipe cleaner to clean the gravity drain hose. Copyright 2000, 2002 Dri-Eaz Products, Inc. 3 SPECIFICATIONS Model DRIZAIR 80 and 80 DX DRIZAIR 1200 DRIZAIR 2000 LG DRIZAIR 2400 LG Water Removal, maximum 80 pints (10 gallons) 38 liters 123 pints (15 gall.) 58 liters 198 pints (25 gallons) 94 liters 240 pints (30 gallons) 114 liters Water Removal, AHAM 40 pints (5 gallons) 19 liters 64 pints (8 gallons) 30 liters 110 pints (14 gall) 52 liters 148 pints (18.5 gall.) 70 liters Airflow 200 cfm 360 cmh 225 cfm 385 cmh 365 cfm 700 cmh 365 cfm 600 cmh Use Weight 62 lb (76 DX) 31 kg (39 DX) 80 lbs 36 kg 132 lbs 60 kg 160 lbs 73 kg Dimensions 21x14x16 in 34x19x20 (DX) 53x36x41 cm 86x48x51 (DX) 32x20x20 in 83x50x50 cm 41x24x23 in 103x61x57 cm 47x24x27 in 120x61x6 9 cm Operating range 55° - 95° F 13° - 35° C 33° - 100° F 0° - 38° C 33° - 100° F 0° - 38° C 33° - 100° F 0° - 38° C Safety Listings UL, C-UL UL, C-UL UL, C-UL UL, C-UL Filter Foam Foam or Paper Foam or Paper Foam or Paper Defrost Thermostat – Fan Defrost Hot Gas Bypass Hot Gas Bypass Hot Gas Bypass Pump Centrifugal (DX only) Centrifugal Centrifugal Centrifugal Refrigerant R-134A R-22 R-22 R-22 Compressor 3,926 BTU Reciprocating 6,670 BTU Rotary 10,120 BTU Rotary 13,315 BTU Rotary One dehumidifier will dry the air in APPROXIMATELY the size of the following drying chamber or room(s) with a standard ceiling. Soaking wet 200 sq ft 20 sq meters 350 sq ft 30 sq m 550 sq ft 50 sq m 750 sq ft 70 sq m Moderately wet 300 sq ft 30 sq meters 500 sq ft 45 sq m 825 sq ft 75 sq m 1,100 sq ft 100 sq m Mostly dry 600 sq ft 60 sq meters 1,000 sq ft 90 sq m 1650 sq ft 150 sq m 2,200 sq ft 200 sq m Specifications are subject to change without notice. Some values are approximate. TROUBLESHOOTING In COLUMN 3, "FS" or Field Solutions can be handled by the technician in the field. Others solutions should be handled by a repair technician – an "AST" or Authorized Service Technician. WARNING: All the service procedures below should be executed with the power turned off, i.e. unplugged. PROBLEM CAUSE See above SOLUTION Unit does not operate No power to machine Switch not turned on FS FS Plug in the unit; check power at outlet Turn on the switch Compressor will not start Unit needs 5 minutes before re-start Overload preventing start up Faulty or broken wire Defective relay Compressor not running FS FS AST AST AST Switch off unit, wait 5 minutes before starting Reduce room temperature below 100° F (38° C) Replace or repair broken/loose wire Check relay with volt/amp meter Contact distributor or Dri-Eaz Products Blower wheel not turning Obstructed blower Loose blower wheel set screw Loose or broken wire Burned out fan motor FS FS AST AST Remove obstruction Tighten set screw Replace broken wire Replace fan motor Dehumidifier operating but room not dry Not enough time to dry Poor air movement Excessive air infiltration FS FS FS Allow more time for drying Increase air movement with TurboDryers Reduce airflow into the area being dried Only partial frost or moisture on coils Possible leak in system Low charge in system AST AST Check for leak with gas leak detector Repair and recharge system No moisture or frost on coils Possible leak in system Capillary tubing damaged Compressor not running AST AST AST Check for leak with gas leak detector Look for damage, replace tubing Contact distributor or Dri-Eaz Products Unit continuously in defrost Room temperature too low Defective control assembly Defective bypass relay valve FS AST AST Increase room temperature Replace control assembly Replace bypass valve Unit does not defrost (heavy frost or ice persists over several hours) ...
Other models in this manual:Dehumidifiers - DRIZAIR 2000 LG (113.41 kb)
Dehumidifiers - DRIZAIR 1200 (113.41 kb)
Dehumidifiers - DRIZAIR 2400 LG (113.41 kb)