Login:
Votes - 2, Average rating: 3.5 ( )

User manual Danby, model DDR25E

Manafacture: Danby
File size: 258.76 kb
File name: 591b9011-76fa-4639-9f81-a81a93891784.pdf
Language of manual:enfr
Free link for this manual available at the bottom of the page



manual abstract


FOR YOUR SAFETY: To reduce the risk of fire or explosion, do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Improper connection of the equipment-grounding conductor can result in a risk of GROUNDING electrical shock. Check with a qualified electrician or service person if you are in doubt INSTRUCTIONS as to whether your appliance outlets are properly grounded. • This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electrical current. This appliance is equipped with a cord having an equipment-grounding conductor and 3 prong grounding plug. The plug must be connected into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. • Do not modify the plug provided with this appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. • If the household electrical supply does not meet the above specifications, or it you are not sure your home has an effective ground, have a qualified electrician or your local electrical utility company check it and correct any problems. SAVE THESE INSTRUCTIONS! 2 INSTALLATION INSTRUCTIONS LOCATION • Select a suitable location, making sure you have easy access to an electrical outlet (avoid the use of extension cords). If it is absolutely necessary to use an extension cord, use an approved “air conditioner” heavy duty extension cord ONLY (available at most local hardware stores). • Make sure there are no obstructions restricting airflow through the front air intake grill. Maintain a minimum clearance of at least 20 cm (8”) between adjacent walls and the back of the unit, to allow for proper air circulation and maximum efficiency. To obtain maximum operating efficiency from your dehumidifier, the recommended (room ambient) operating temperatures should be between 6°C (42.8°F)- 35°C (95°F). • It is important to remember the efficiency of a dehumidifier will be effected/influenced by the rate at which new humid air (moisture) is allowed to infiltrate the same space/area. To maintain efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors and windows closed. CASTOR INSTALLATION NOTE: Castor installation is recommended to avoid damage to floors. 1) Remove the castors from the bucket of the dehumidifier. 2) Position the dehumidifier on its side. 3) Locate the arrow on the bottom of the dehumidifier and insert the castor according to the arrow direction. 4) Slide the castor in as far as it will go. The castor will snap intoplace. 5) Repeat steps 1 to 4 for the other 3 castors. 3 FEATURES • Soft touch (Electronic) Control Key Pads Dehumidified Dry Air Vent • Auto-Sensing Humidity Control Control Panel • 2 Fan Speed Settings (High / Low) Intake • Delay Start Protection (Compressor) • Auto-Defrost (De-Icer) • Full Bucket Indicator Light • Front Mounted Water Tank (Removable) • Direct Drain Option Continuous • Quiet Operation Drain Outlet • Adjustable Humidity Settings (30% - 90%) Handle Moist Air • Easy Roll Castors (4) Air Filter • Removable Air Filter Drain Bucket Castors OPERATING INSTRUCTIONS 8 765 1 23 9 1) POWER Button: On / Off 2) FAN SPEED Button: High / Low 3) TIMER Button: When unit is operating, pressTIMER to set number of hours desired until unit will shut off.When unit is in stand-by, press TIMER to set number of hours desired until unit will turn on. Setting timer from 1-24 hours. To cancel the timer, proceed as above but set the “timer off” to zero (0) hours. 4) °C/°F Button: Press the °C/°F button to togglebetween Celsius and Fahrenheit. 5) Receiving Sensor 6) SET HUMIDITY/CURRENT HUMIDITYDISPLAY: When machine is running, it displaysthe current humidity. Press UP or DOWN buttons 4 to select humidity setting. The humidity is adjusted in increments of 5% by each press. Adjustablerange is within 30% RH to 90% RH. 10 secondsafter setting humidity, the display will change back to the current humidity. 7) CURRENT TEMP/ TIMER SET DISPLAY: When machine is running, it displays the currenttemperature. Press the TIMER button to set themachine to shut off automatically after specifiedamount of time. 10 seconds after displaying thetimer, the display will change back to current temperauture. 8) DEFROST LIGHT: When temperature is low, unit enters defrost mode and defrost lightilluminates. 9) BUCKET FULL LIGHT: When water tank is full, bucket full light illuminates. 4 OPERATING INSTRUCTIONS (cont’d) START OPERATION 1) Place the product in an uprightposition on a flat, stable, and heat- resistant surface. Make sure there is nothing flammable or heat sensitivewithin 100cm (39 inches). Operatingthe product in any other positioncould cause a hazard. 2) Insert the plug into a suitable wallsocket. The dehumidifier is suitable for operating on an electricity supplyhaving the same voltage as that shown on its rat...

Other models in this manual:
Dehumidifiers - DDR30E (258.76 kb)
Dehumidifiers - DDR45E (258.76 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category