|
manual abstract
Keep all doors and windows closed. FEATURES • Soft touch (Electronic) Control Key Pads • Full Bucket Indicator Light • Auto-Sensing Humidity Control • Easy Roll Castors (4) • Adjustable Humidity Settings (35% - 80%) • Front Mounted Water Tank (Removable) • 2 Fan Speed Settings (High / Low) • Direct Drain Option (HOSE NOT INCLUDED) • Delay Start Protection (Compressor) • Quiet Operation • Auto-Defrost (De-Icer) • Removable Air Filter Control Panel Handle Moist Air Intake Air Filter Drain Bucket Castors Dehumidified Dry Air Vent Continuous Drain Outlet 3 OPERATING INSTRUCTIONS 8 765 49 1 23 1) POWER Button: On / Off 2) FAN SPEED Button: High / Low 3) TIMER Button: When unit is operating, press TIMER to set number of hours desired until unit will shut off.When unit is in stand-by, press TIMER to set number of hours desired until unit will turn on. Setting timer from 1-24 hours. To cancel the timer, proceed as above but set the “timer off” to zero (0) hours. 4) °C/°F Button: Press the °C/°F button to togglebetween Celsius and Fahrenheit. 5) Receiving Sensor 6) SET HUMIDITY/CURRENT HUMIDITY DISPLAY: When machine is running, it displays the current humidity. Press UP or DOWN buttons to select humidity setting. The humidity is adjusted inincrements of 5% by each press. Adjustable range iswithin 30% RH to 90% RH. 10 seconds after setting humidity, the display will change back to thecurrent humidity. 7) CURRENT TEMP/ TIMER SET DISPLAY: When machine is running, it displays the currenttemperature. Press the TIMER button to set the machine to shut off automatically after specifiedamount of time. 10 seconds after displaying the timer, the display will change back to current temperauture. 8) DEFROST LIGHT: When temperature is low, unit enters defrost mode and defrost light illuminates. 9) BUCKET FULL LIGHT: When water tank is full, bucket full light illuminates. REMOTE CONTROL The functions work the same as your dehumidifiers touch controls. 1) Power Key: On / Off B) The default display is room temperature. 2) Fan Speed Key: High/Low C) When “+” or “-” button is pressed, 3) On / Off Timer Key: the set temperature is displayed and may1 4 In running mode: Auto switch Off be adjusted. After 10 seconds the display In standby mode: Auto switch On will revert back to room temperature. The remote operates within a range of 64) Temperature display selector buttonmeters (16.4 ft.)from the receiver located2 (Celsius / Fahrenheit): Press the°C/°F inside the main unit. Any obstruction 5 switch button to toggle between °C and °F. between the receiver and remote maycause signal interference, limiting the3 5) Timer/ Temperature Buttons: ability to program the main unit. A) Used for adjusting the timer and This Class B digital apparatus complies thermostat. with Canadian ICES-003. BATTERIES: Remove the cover on the back of the remote controller and insert the batteries with the (+) and (-) poles pointing in the proper direction. CAUTION: Use only AAA or IECR03 1.5V batteries. Remove the batteries if theremote controller is not used for one month or longer. Do not attempt to recharge thesupplied batteries. All batteries should be replaced at the same time. Do not dispose of the batteries in a fire as they may explode. 4 OPERATING INSTRUCTIONS (cont’d) START OPERATION 1) Place the product in an uprightposition on a flat, stable, and heat- resistant surface. Make sure there is nothing flammable or heat sensitivewithin 100cm (39 inches). Operatingthe product in any other position could cause a hazard. 2) Insert the plug into a suitable wall socket. The dehumidifier is suitable for operating on an electricity supplyhaving the same voltage as that shown on its rating label. 3) Make sure the water tank is correctly located. After switching on the machinefor the first time, if the “Bucket Full” light illuminates, pull out the water tank and check that the “float” lever is able to move freely, then return thewater tank to the correct position (Fig. 1). Fig. 1 WATER FULL When the water tank is full and/or incorrectly positioned inside the cabinet, the water INDICATOR full red light turns on and remains on until such time that the tank is emptied and/or LIGHT (RED) correctly re-positioned. This condition will result in the immediate shut down of the dehumidifying system (both compressor and fan motor operations are terminated). This is a safety feature. When the water tank is emptied and/or correctly re-positioned, the dehumidifier will resume operation automatically. NOTE: It may take several minutes before operating conditions resume. BUCKET FULL LIGHT • When the water tank is full the machine will stop and the“Bucket Full” light will illuminate. • The water tank should be carefully removed from the machine by sliding it outward from the front of the unit, and it should be emptied. When the empty tank is replacedproperly in the machine, the unit will start up and run normally (Fig. 2). NOTE: Please use both hands to carefully empty the water tan...
Other models in this manual:Dehumidifiers - DDR5009REE (250.42 kb)
Dehumidifiers - DDR6009REE (250.42 kb)