Login:
Votes - 3, Average rating: 3 ( )

User manual Frigidaire, model 66129900901

Manafacture: Frigidaire
File size: 276.38 kb
File name: f97d9bf6-0206-4526-b795-9ad439cce3dc.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


The unit will cycle on and off keeping the desired level of comfort. ................ 4 4. To shut the unit down, rotate the HUMIDITY knob to the OFF position. Note: the power indicator will still be lit when the unit is turned off. Only removing the plug will extinguish these lights. REMOVING COLLECTED WATER 1. Emptying the Bucket: a. When the bucket is full the unit will shut down and the BUCKET FULL indicator light will illuminate. b. Do not move the unit at this point otherwise water may spill on the floor. c. Press sides of bucket gently to unclip the bucket from the unit. d. Remove the bucket as shown in the photographs below and empty the bucket. e. Replace the empty bucket back into the unit and once seated correctly the unit will start up again. f. You should hear a click when the bucket is in the correct position If the bucket full light does not extinguish, check that the float is correctly snapped in place as indicated by the photo. 5 2. Continuous Drainage: a. For constant drainage operation, you will need a garden hose and a drain nearby to discharge the water into. b. Remove the bucket from the unit and set aside. c. Lift up the side flap located on the left side of the unit as looking from the front. (fig.1) d. Insert the female threaded end of the hose through the opening. (fig.2) e. Screw the garden hose onto the threaded portion of the tray underneath the bucket opening. (fig.3) f. Make sure the hose is secure so there are not leaks. g. Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing. h. Place the end of the hose into the drain. i. Place the bucket back in the unit and make sure that it is located correctly. (fig.4) j. Select the desired humidity setting and fan speed on the unit for continuous draining to start. fig.1 fig.2 fig.3 fig.4 Note: If the unit stops operating check that the bucket full light is illuminated. If it is remove the bucket and empty the contents and then check the seal between the hose and the drip tray. If there is a small leak then replace the hose gasket and re-tighten the hose. CARE AND CLEANING 1. Filter a. Remove the filter every two weeks based on normal operating conditions. b. To remove the filter, c. Wash the filter with clean water then dry. d. Re-install the filter. 2. Cabinet a. Dust cabinet with an oil-free cloth, or using a damp cloth. b. Vacuum grill using brush attachment. 3. Water Bucket a. Clean bucket with warm water and detergent. 6 Before calling for service, review this list. It may save you time and expense. ThisAvoid Service Checklist list includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE SOLUTION DEHUMIDIFIER D DDOES N NNOT O OOPERATE. Plug is disconnected from outlet. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. The dryness level you selected has been reached. Dehumidifier automatically shuts off when selected amount of moisture has been removed from the air. If you want to remove more moisture, rotate the knob until it points to the CONTINUOUS setting. control to the desired setting. Bucket not installed properly. See “ Removing Collected Water.” Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this occurs. Empty bucket and return bucket to position. Dehumidifier is not turned on. rotate the knob to " CONTINUOUS " . DEHUM IDIFIER R RR UNS T TT OO M MM UCH. W indows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside. Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate. Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of vacuum cleaner to clean grill. See “ Care and Cleaning.” Dehumidifier must be placed in a space that does not restrict air flowing into the rear coil or out of the front grill. Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the longer the dehumidifier will operate. DEHUM MM IDIFIER I II S O OO PERA TUING B BB UT ROOM I II S N NN OT D DD RY E EE NOUGH. Humidity setting is too high. rotate the knob to a lower setting. Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the longer it takes for the room air to become dry. Dehumidifier does not have sufficient clearance to operate. Air flow to front grill is blocked. See “ Selecting a Location.” Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below 41°F (5°C). See “ Operating Conditions.” Refer to causes under DEHUMIDIFIER RUNS TOO MUCH. FROST A AAPPEARS O OON C CCOILS A AABOVE Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the BUCKET O OOR D DDRIP T TTRAY. coil. Frost will usually disappear within 60 minutes. Room Temperature is too ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category