Login:
Votes - 3, Average rating: 3.7 ( )

User manual Vixen, model R-323EX(NX)

Manafacture: Vixen
File size: 1.2 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


NIL 1. 3 AXIS 2. 2 AXIS 3. 1AXIS 4. NIL 1. 2 AXES 2. AXIS 3. NIL 4. Setting the Shot input: [SHOT INPUT] 03 TIMES Set the shot number for Shot distance measurement. • The valid range of values for the shot number is from 1 to 99. • This setting is enabled only when the shot number (Above 2.) has been set to “4. INPUT”. 5. Selection of Laser plummet: [LD PLUM.] Laser plumb ON/OFF is selected. 6. Selection of Tilting angle display: [TILT DISP.] X and Y tilting values are displayed. 7. Selection for Minimum tilt display: [TILT DISP. UNIT] COARSE or FINE: 8. Selection of Reflectorless range: [RANGE] If you need the Normal or Long range. 9. Selection of Long range message: [MESSAGE] If you need the long range message. 10. Selection of Long range setup: [SET UP] If the above No.7 selection is required each time or permanent. 11. Selection of primary MEAS setting:[PRIM.MEAS KEY] Select whether the primary distance measurement is MEAS SHOT or MEAS CONT or TRACK SHOT or TRACK CONT. 1. OFF 2. ON 1. OFF 2. ON 1. COARSE 2. FINE 1. NORMAL 2. LONG 1. ON 2. OFF 1. EACH TIME 2. PERMANENT 1. MEAS SHOT 2 MEAS CONT 3. TRACK SHOT 4. TRACK CONT 12. Selection of second MEAS setting:[SEC.MEAS KEY] Select whether the second distance measurement is TRACK CONT or TRACK SHOT or MEAS CONT or MEAS SHOT. 1. TRACK CONT 2 TRACK SHOT 3. MEAS CONT 4. MEAS SHOT 13. Selection of Minimum angle display: [MIN UNIT ANG] Select whether to set the minimum angle display mode to “COARSE (5 seconds)” or “FINE (1 second)”. 14. Selection of Vertical angle style: [V. ANG. STYLE] Select whether the 0 point for vertical angle is set to be “Z.0”, “H.0” or “COMPAS”. 15. Selection for Automatic power-off function: [AUTO OFF] Select the time interval (10, 20 or 30 minutes) for activating the automatic power-off function, or select NIL, disabling the function. • The automatic power-off function automatically turns the power supply off after the specified period of time (in minutes) when no operation for distance measurement or for key entry has been performed with the angle remaining unchanged. 16. Selection for Distance measurement automatic power-off function: [EDM OFF] Select the time interval (3, 5 or 10 minutes) for activating the distance measurement automatic power-off function or select NIL, disabling the function. • The distance measurement automatic power-off function automatically poweroff distance measurement after the specified period of time when no key operation has been performed with the measured value remaining unchanged (over about 0.1m) during measurement. 1. COARSE 2. FINE 1. Z.0 2. H.0 3. COMPAS 1. 10 MIN 2. 20 MIN 3. 30 MIN 4. NIL 1. 3 MIN 2. 5 MIN 3. 10 MIN 4. NIL 17. Selection for Automatic illumination power-off function: [ILLU. OFF] Select the time interval (3, 5 or 10 minutes) for activating the automatic illumination power-off function or select NIL, disabling the function. 18. Selection for Distance measurement buzzer: [DIST. BUZ] Select whether to enable or disable the beep when the prism receives a light during distance measurement or during repeated distance measurement. 19. Selection for H. angle 90° buzzer: [QUAD BUZ] Select whether to enable or disable the beep at every 90° during angle measurement. 20. Selection of Distance measurement signal: [MEAS. SIGNAL] Select whether to display a signal indicator or AIM value to be displayed from when distance measurement is started to when measured data is displayed. 21. Selection of Automatic distance measurement: [AUTO MEAS.] Automatic distance measurement repeats measurement automatically when the telescope has been collimated at the prism. Select NIL, MEAS or TRACK. 22. Selection for priority Display: [PRIORITY DISP] Select the display order of the sets of display items which pressing the [DISP] key cycles through. The set of display items selected here appears first after the power is turned on. 1. 3 MIN 2. 5 MIN 3. 10 MIN 4. NIL 1. ON 2. OFF 1. OFF 2. ON 1. MARK 2. VALUE 1. NIL 2. MEAS 3. TRACK 1. HA HD VD 2. HA VASD 3. HAVAHD SD VD 8.10 Initial setting 4 1. Selection of Temperature unit setting: [TEMP. UNIT] Select °C or °F as the unit for Temperature. 1. °C 2. °F 2. Selection of Pressure unit setting: [PRESS UNIT] Select hPa (hectopascal), mmHg, inchHg as the unit for pressure to be input. 3. Selection of Distance unit setting: [DIST. UNIT] Select m or ft or ft+inch as the unit for Distance. 4. Selection of Angle unit setting: [ANG. UNIT] Select DEG or DEC or GRD or MIL as the unit for Angle. 1. hPa 2. mmHg 3. inchHg 1. m 2. ft 3. ft+ inch 1. DEG 2. DEC 3. GRD 4. MIL 8.11 Initial setting 5 1. Selection of Transfer rate (baud rate): [BAUD UNIT] Select a baud rate of 1200, 2400, 4800 or 9600. 2. Selection of Data bits: [DATA LENGTH] Select a data length of 8 bits or 7 bits. 3. Selection of Parity: [PARITY BITS] Select no (NIL) parity bit, even parity or odd parity. 4. Selection of Stop bit: [STOP BITS] Select the number of stop bits to be used: 1 or 2. 1. 1200 2. 2400 3. 4800 4....

Other models in this manual:
Optical Devices - R-315EX(NX) (1.2 mb)
Optical Devices - R-315EX(NX) (1.2 mb)
Optical Devices - R-322EX(NX) (1.2 mb)
Optical Devices - R-323EX(NX) (1.2 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category