Login:
Votes - 3, Average rating: 3.3 ( )

User manual Petsafe, model UL-275

Manafacture: Petsafe
File size: 126.66 kb
File name: 92b58034-1441-4d69-b0e7-626148649a1b.pdf
Language of manual:itenesfrdenlptca
Free link for this manual available at the bottom of the page



manual abstract


The static correction is delivered through two contact points that touch the dog’s neck. There are two sets of contact points that can be used on your receiver.The longer contact points should be used on dogs with long hair. The UL-275 Receiver is enclosed in a waterproof case and is mounted on a polypropylene collar. The collar will fit a dog with a neck size varying from 9 to 22 inches. The UL-275 Receiver contains a LED indicator light. The light acts as a low battery light and confirms which one of five correction levels are set. The receiver is equipped with memory backup. After you replace the batteries in the receiver, you will not have to reset the correction level. The LED indicator light will flash for the correction level last set. Inserting the Battery Module in the Receiver Remove the Battery Module From the Receiver - Insert a coin into the slot just below the white arrow.Turn the coin counter-clockwise, and remove the battery module. Inserting the Battery Module – Insert the module by aligning the battery module arrow with the small arrow on the side of the case, and press the module down into the battery compartment. Place a coin in the slot as shown, and turn the coin clockwise until it stops.The battery module arrow should now be aligned with the lock symbol. Testing the System Changing the Correction Level - The correction levels change incrementally from the current level and revert back to 1 from 5. Refer to the Receiver LED Function and Response table to choose the correction level that best fits your pet. Remove the switch cover with a small coin. With battery installed, press the small button on the back of the receiver until LED lights and release. The LED will then flash to show the current correction level. To change to the next level, push the button in again once the last flash has been displayed. Please note that the button must be pressed within 5 seconds from the last flash to change to the next level. After setting the correction level, replace the switch cover to protect the switch from the outside environment. Testing the Receiver - Attach the test light to the contact points according to the picture. Walk towards the boundary wire until the test light begins to fl ash. This will indicate the system is functioning properly. If the test light did not flash, check the battery installation, and be sure that the contact points are secured hand tight. Receiver LED Function and Response Receiver LED Function Correction LED Indicator Light Response Size of Dog Correction Level 1 No Correction, Beep Only 1 Flash Training Only Correction Level 2 Low Correction 2 Flashes Less than 20lbs Correction Level 3 Medium Correction 3 Flashes 20lbs - 50lbs Correction Level 4 Medium High Correction 4 Flashes Greater than 50lbs Correction Level 5 High Correction 5 Flashes Hard to Train Pets Low Battery Flashes every 4-5 seconds Placing the Receiver on Your Dog Correction When placing the receiver on your Level Switch dog’s neck, make sure it is positioned where the two contact points are touching your dog’s skin. If your dog’s hair is so thick that it keeps the contact points from touching your dog’s skin, you might want to use the longer contact points that are supplied with your system. NOTE: The collar is properly positioned when you are able to get one finger between the contact points and your pet’s skin. CAUTION: Leaving the collar on too tight and for long periods of time can cause, Pressure Necrosis. This is a condition where the skin deteriorates over time. To prevent this, check and clean your pet’s neck regularly. If a rash or sore forms, remove the receiver for a few days. When replacing the collar, make sure both the contact points and your dog’s neck are clean. FRENCH Le recepteur UL-275 Le recepteur UL-275 contient des composants electroniques capables de detecter le champ magnetique emis par le cable-barriere et de le convertir en signal electrique de rappel a l’ordre. Ce signal electrique est delivre par deux palpeurs montes sur le collier du chien. Deux paires de palpeurs peuvent etre montees sur le collier recepteur. Les palpeurs allonges seront employes pour les chiens a poils longs. Le recepteur UL-275 est contenu dans un boitier etanche et monte sur un collier en polypropylene.Le collier s’adaptera aux chiens dont le tour de cou mesure entre 23 et 56 cm. Le recepteur UL-275 est pourvu d’un temoin lumineux. Ce temoin s’allumera pour indiquer que les piles doivent etre changees et pour confirmer lequel des 5 niveaux de rappel a l’ordre a ete programme. Le recepteur est muni d’une memoire de sauvegarde. Apres avoir remplace les piles du recepteur, vous n’aurez pas a reprogrammer le niveau du signal de rappel a l’ordre. Le temoin lumineux clignotera pour indiquer le dernier niveau programme. Insertion des piles dans le recepteur Installation du bloc-piles dans le recepteur Retirez le bloc-piles du recepteur -Introduisez une piece de monnaie dans la fente juste au-dessous de la...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category