Login:
Votes - 3, Average rating: 3.7 ( )

User manual Giant, model HR3025

Manafacture: Giant
File size: 291.36 kb
File name: e526324f-b5b8-421e-ab70-775aed861729.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


oz. Temperature of Pumped Fluids.............................................................Up to 80 °F Inlet Port...............................................................................................1 x 1/2" NPT Discharge Ports....................................................................................3/8" NPT Shaft Rotation.......................................................................................Clockwise Weight...................................................................................................11.7 lbs. (12.7 lbs.) Width.....................................................................................................6-9/16" Height...................................................................................................7-25/32" Swash Plate Bore.................................................................................3/4" x 3/16" Keyway Valve Type............................................................................................Polyamide Plastic 1 A 25 PSIG minimum inlet pressure is required. HR2527A ELECTRIC HORSEPOWER REQUIREMENTS RPM GPM 1000 PS11500 PSI 2000 PSI 2750 PSI 3450 2.5 1.7 1 2.6 3.4 4.7 HR2527A G REQ ¡AS HORSEPOWER UIREMENTS RPM GPM 1000 PS 1500 PSI 2000 PSI 2750 PSI 3450 2.5 2.3 3.4 4.5 6.3 HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the Following formula: Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100 з Specifications Model HR3025 Axial Pump Volume HR3030....................................................................................3.0 GPM Maximum Discharge Pressure.............................................................2500 PSI Maximum Inlet Pressure......................................................................Up to 90 PSIG1 RPM.....................................................................................................3450 Plunger Diameter..................................................................................I6mm Stroke....................................................................................................5.9mm (8.0 0 angle) Crankcase Oil Capacity........................................................................4.5 fl. oz. Temperature of Pumped Fluids.............................................................Up to 80 °F Inlet Port...............................................................................................I x 1/2" NPT Discharge Ports....................................................................................3/8" NPT Shaft Rotation.......................................................................................Clockwise Weight...................................................................................................11.4 lbs. Width.....................................................................................................6-7/16" Height...................................................................................................10-1/4" Swash Plate Bore.................................................................................3/4” x 3/16” Keyway Valve Type............................................................................................Polyamide Plastic 1 A 25 PSIG minimum inlet pressure is required. HR3025 ELECTRIC HORSEPOWER REQUIREMENTS RPM GPM 1000 PS11500 PSI 2000 PSI 2500 PSI 3450 3.0 2.1 1 3.1 4.1 5.1 HR3025 Gi REQ AS HORSEPOWER UIREMENTS RPM GPM 1000 PS 1500 PSI 2000 PSI 2500 PSI 3450 3.0 2.7 4.1 5.5 6.8 HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the Following formula: Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100 4 Specifications Model HR3030 Axial Pump Volume HR3030....................................................................................3.0 GPM Maximum Discharge Pressure.............................................................3000 PSI Maximum Inlet Pressure......................................................................Up to 90 PSIG RPM.....................................................................................................3450 Plunger Diameter..................................................................................I6mm Stroke....................................................................................................5.9mm (8.0 0 angle) Crankcase Oil Capacity.......

Other models in this manual:
Water and Air Pumps - HR2527A (291.36 kb)
Water and Air Pumps - HR3030 (291.36 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category