User manual York, model SUNLINE 2000 B2CH180

Manafacture: York
File size: 532.13 kb
File name: ee2104df-574c-4823-8669-f0420a2cf0c9.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Per Unit) SCROLL (6.5 TON NOMINAL CAPACITY) 2 AIR FILTERS (SEE NOTE) QUANTITY PER UNIT 457 x 610 x 51 (mm) 18 x 24 x 2 (in.) 5 TOTAL FACE AREA m2 / Ft.2 1.40 / 15.0 CHARGE REFRIGERANT 22 SYS. #1 (kg. / lbs.) SYS. #2 (kg. / lbs.) 9.5 / 21.0 9.5 / 21.0 WEIGHTS (kg. / lbs.) BASIC UNIT 180 948 / 2091 OPTIONS Economizer 73 / 160 Motorized Damper 68 / 150 18 kW 11 / 25 Electric 36kW 14 / 30 Heater 54 kW 16 / 35 72 kW 18 / 40 ACCESSORIES Roof Curb 180 79 / 175 Barometric Damper 20 / 45 Wood Skid* 180 91 / 200 *Allows handling of unit using 2286mm (90") long forks. NOTE: Filter racks are adapted to accept 25mm (1") or 51mm (2") filters. Unitary Products Group 035-18895-000-A-0902 1235 (48-5/8") (180) 3181 (125-1/4") (180) 616 (24-1/4”) (180 MBH RETURN AIR All dimensions are in millimeters and inches, unless otherwise specified. They are subject SUPPLY AIR to change without notice. Certified dimensions will be provided upon request. OUTDOOR AIR CLEARANCES (mm / in.) OUTDOOR AIR (Economizer) Front 914 / 36 Back 610 / 24 (Less Economizer) 1245 / 49 (With Economizer) Left Side (Filter Access) 610 / 24 Right Side (Outdoor Coil) 914 / 36 Below Unit 20 / 0 Above Unit* 1829 / 72 With 914 / 36 Maximum Horizontal Overhang (For Outdoor Air Discharge) UTILITIES ENTRY DATA NOTE: Unit and ductwork are approved for zero clearance to combustible materials when equipped with electric heat. *Units must be installed oudoors. Overhanging structures or shrubs should not obstruct outdoor air discharge outlet. HOLE OPENING DIAMETER (mm / in.) USED FOR A 28.6 / 1-1/8 KO 19.1 / 3/4 NPS (Fem.) Control Wiring Front Bottom B 92.1 / 3-5/8 KO 76.2 / 3 NPS (Fem.) Power Wiring Front Bottom FIG. 7 - DIMENSIONS AND CLEARANCES Unitary Products Group 035-18895-000-A-0902 DUCT COVERS - Units are shipped with all air duct openings covered. For sideflow duct applications; 1.Remove and discard the side supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For downflow duct applications; 1. Remove the side supply and return air duct covers to gain access to the bottom supply and return air duct covers. 2. Remove and discard the bottom duct covers. 3. Replace the side duct covers. 727 (28-5/8") (180) DETAIL “X” ACCESSORY SIDE SUPPLY AND RETURN AIR DUCT OPENINGS 397 1558“ 610 (24") (180) DETAIL “Y” UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS FIG. 7 (Cont'd.) - DIMENSIONS AND CLEARANCES Unitary Products Group 035-18895-000-A-0902 TABLE 4 - SUPPLY AIR BLOWER PERFORMANCE DOWNFLOW DUCT APPLICATIONS (m3 /s) - B*CH180 UNIT BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* AIRFLOW 1.77 m3/s 2.07 m3/s 2.36 m3/s 2.66 m3/s 2.95 m3/s ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) 845 6.0 273 1.56 1.8 223 1.79 2.2 198 2.09 2.5 174 2.38 2.9 149 2.68 3.2 885 5.0 322 1.64 1.9 273 1.94 2.3 223 2.24 2.7 198 2.53 3.1 174 2.83 3.4 925 4.0 372 1.71 2.1 322 2.01 2.5 248 2.38 2.9 223 2.68 3.3 --- 960 3.0 422 1.79 2.2 347 2.16 2.6 298 2.46 3.0 248 2.83 3.4 --- 1000 2.0 446 1.86 2.3 397 2.24 2.7 347 2.61 3.2 ------ 1040 1.0 496 1.94 2.4 446 2.38 2.9 372 2.76 3.3 ------ DOWNFLOW DUCT CONNECTIONS (CFM) - B*CH180 UNIT BLOWER SPEED, (RPM) MOTOR PULLEY (TURNS OPEN)* AIRFLOW 3750 CFM 4380 CFM 5000 CFM 5630 CFM 6250 CFM ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) 845 6.0 1.1 2.1 1.8 0.9 2.4 2.2 0.8 2.8 2.5 0.7 3.2 2.9 0.6 3.6 3.2 885 5.0 1.3 2.2 1.9 1.1 2.6 2.3 0.9 3.0 2.7 0.8 3.4 3.1 0.7 3.8 3.4 925 4.0 1.5 2.3 2.1 1.3 2.7 2.5 1.0 3.2 2.9 0.9 3.6 3.3 --- 960 3.0 1.7 2.4 2.2 1.4 2.9 2.6 1.2 3.3 3.0 1.0 3.8 3.4 --- 1000 2.0 1.8 2.5 2.3 1.6 3.0 2.7 1.4 3.5 3.2 ------ 1040 1.0 2.0 2.6 2.4 1.8 3.2 2.9 1.5 3.7 3.3 ------ NOTES: 1. Blower performance includes fixed outdoor air, standard unit filters, a dry indoor coil and no electric heat. 2. Refer to Table 5 for additional static resistances. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. * Do NOT close the pulley below 1 turn open. Unitary Products Group 035-18895-000-A-0902 TABLE 5 - STATIC RESISTANCES1 DESCRIPTION EXTERNAL STATIC PRESSURE DROP - RESISTANCE, iwg/Pa m3/s (CFM) 180 UNIT 1.77 (3750) 2.12 (4500) 2.48 (5250) 2.83 (6000) WET COIL 0.1 / 25 0.1 / 25 0.1 / 25 0.1 / 25 ELECTRIC HEAT OPTIONS 18 kW 0.1 / 25 0.1 / 25 0.1 / 25 0.1 / 25 36 kW 0.1 / 25 0.1 / 25 0.2 / 50 0.2 / 50 54 kW 0.1 / 25 0.2 / 50 0.2 / 50 0.3 / 75 72 kW 0.1 / 25 0.2 / 50 0.3 / 75 0.4 / 99 ECONOMIZER OPTION 0.1 / 25 0.1 / 25 0.1 / 25 0.1 / 25 SIDEFLOW DUCT CONNECTIONS2 0.2 / 50 0.2 / 50 0.3 / 75 0.3 / 75 1Deduct these resistance values from the available external static pressures shown in the respective Blower Performance Table. (See Note 2 for exception). 2Since ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category