manual abstract


DANGER RISK OF ELECTROCUTION! Improper connection of the equipment-groundingconductor can result in a risk of shock or electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not use any type of adapter with this product. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. WARNING RISK OF ELECTRICAL SHOCK! Thisproductmustbegrounded.If there should be a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding type plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded inaccordancewithalllocalcodes and ordinances. WARNING RISK OF BODILY INJURY! Never attempt to open the Air Tank Drain Valve when more than 10 PSI of air pressure is in the air tank! PREPARATION INSTRUCTIONS INITIAL SET-UP: 1. Remove the air compressor from the carton. 2. Read safety warnings before setting-up air compressor. 3. If your unit contains oil, remove the oil travel plug and insert the oil dipstick. Ensure the oil level in the air compressor pump is adequate. If low, add SAE non-detergent oil as recommended below: Ambient Temperature SAE Viscosity 0-32°F SAE 10W 32-80°F SAE 20W 60-103°F SAE 30W LOCATION: 1. In order to avoid damaging the air compressor, do not incline the aircompressor transversely or longitudinally more than 10°. 2. Place air compressor at least 12 inches away from obstacles that mayprevent proper ventilation. Do not place air compressor in an area: -where there is evidence of oil or gas leaks. -where flammable gas vapors or materials may be present. -where air temperatures fall below 32°F or exceed 104°F. -where extremely dirty air or water could be drawn into the air compressor. ELECTRICAL: 1. USE OF AN EXTENSION CORD IS NOT RECOMMENDED because it could cause the compressor motor to overheat. It's preferable to use additional air hose instead of an extension cord. 2. If use of an extension cord is unavoidable, be sure to use one heavy enough to carry the current your compressor will draw. Minimum cord sizes is as follows: Cord Length Wire Gauge Up to 25 Feet 12 AWG 26 to 100 Feet 10 AWG 101 to 150 Feet 8 AWG 151 to 250 Feet 6 AWG 3. Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the compressor. 4. Examine cords before using. Do not use the compressor if its cord is damages. Do not use a damaged extension cord. 5. Keep cords away from heat and sharp edges. Do not pull on a cord to disconnect a plug -- grasp the plug. 6. Always shut off the compressor Pressure Switch before unplugging the compressor. PRE-START CHECKLIST: 1. Check oil level. Add if necessary. 2. Remove any moisture in the air compressor air tank. NEVER attemptto open the Air Tank Drain Valve when more than 10 PSI of air pressure is in the air tank! Remove excessive pressure with an air tool, then open the Air Tank Drain Valve in the bottom of the air tank. Close tightly when drained. 3. Make sure the Motor/Pressure Switch is in the "OFF" position. 4. Make sure the Safety Relief Valve is working correctly. 5. Make sure all guards and covers are in place and securely mounted. Hand Carry Electric Air Compressor Manual OPERATING INSTRUCTIONS START-UP: 1. Read safety warnings before performing operation. 2. Ensure the Motor/Pressure Switch is in the "OFF" position. 3. Plug the Power Cord into a grounded outlet. 4. Pull the Motor/Pressure Switch up to the "ON" position. This will allow the air compressor to start building up pressure in the air tanks. You will hear an air leak for the first 20-50 seconds until the easy start valve closes. This will stop when correct pressure is achieved. When pressure drops with usage, the air compressor will start building up pressure again. 5. Set pressure by adjusting the Pressure Regulator counterclockwise forless pressure and clockwise for more pressure. 6. If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting". SHUTDOWN: 1. To stop the air compressor, move the Motor/Pressure Switch to the "OFF" position. NEVER stop the air compressor by unplugging it from thepower source. This could result in risk of electrocution. 2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the Safety Relief Valve. 3. Once the Air Tank Pressure Gauge registers under 10 pounds, open the Air Tank Drain Valve under each air tank to drain any moisture. 4. Allow the air compressor to cool down. 5. Wipe the air compressor clean and store in a safe, non-freezing area. MAINTENANCE INSTRUCTIONS WARNING Read the instructi...

Other models in this manual:
Water and Air Pumps - AC1-5E (796.89 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category