|
manual abstract
SaveThisManual For Future Reference. MODEL NOS. 390.262454 390.262553 MODEL NO. 390.262653 I:RI:IF'rSMg N° HYDROGLASS ® HIGH PRESSURE SPRINKLER PUMP • Safety Instructions • Installation • Electrical •Maintenance • Repair Pa_s Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. PRINTED IN U.S.A. Form No. F642-9908 (Rev. 8/18/03) CONTENTS INTRODUCTION INTRODUCTION/XVARRANTY .......................................... 2 Please take a few minutes to read our instructions before you SAFETY ............................................................................... 2 install and use ynur pump. Tbis will help you obtain the full benefits from this pump. It will also help you avoid any need- PREPARATION .................................................................... 3 less service costs that result from causes we cannot control INSTALLATION ................................................................ 3-4 alld cannot cover ill ottr vvarranty. ELECTRICAL..................................................................... 54 OPERATION ........................................................................ 7 MAINTENANCE ............................................................... 8-9 TROUBLESHOOTING ....................................................... 10 REPAIR PARTS .................................................................. 11 FULL ONE YEAR WARRANTY ON CRAFTSMAN* SPRINKLER PUMPS For one year from the date of purchase. Sears will repair or replace this pump, free of charge, if defective in materials or workmanship. LIMITED WARRANTY ON CRAFTSMAN ® HYDROGLASS ®SPRINKLER PUMP After one year and through two years from the date of purchase. Sears will furnish, free of charge, a replacement part for any defective part. You pay for labor. This warranty does not cover repairs on replacemellt parts necessary because of abuse or negligence including failure to install, adiust and operate this pump according to the instructions in the owner's manual. LIHITATION OF LIABILITY SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS OR. EXIa_._ SE_ROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS Some states do_ot allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusi0rr may not apply to you, WARRAIWJ'Y SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT IN THE UNITED STATES. This warranty applies only wlaiie the product is in the United States. This warranty gives you Specific legal fights, and you may also have other rights which vary fIom state to state. Sdaa"s, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179 RULES FOR SAFE INSTALLATION AND OPERATION! Carefully read and follow all safety instructions in this 2.Follow local and/or national plumbing and electrical manual or on pump. codes when installing pump. 3. Keep the well covered while installing pump to prevent This is the safety alert symbol. When you see this leaves and other debris from falling into well, contami symbol on your pump or in this manual, look for one of the nating well and possibly damaging pump. following signal words and be alert to the potential for per 4. Protect pump and piping system from freezing. Allowing sonal injury! pump or water system to freeze could severely damage _ DANGER warns about hazards that will cause pump and voids warranty. serious personal injury, death or major property damage if !_WAFINING]Hazardous Voltage. Can shock, burn, ignored. cause death, or start fires. {_'WARNIN_wARNING warns about hazards that can 5. Disconnect electrical power source before installing or cause serious personal injury, death or major property dam-working on pump. age ff ignored. 6. Ground pump with a ground wire run from grounding lug _ .....CAUTION CAUTION warns about hazards that will on motor to a grounded lead in the service panel. IONj or 7. Line winagc and frequency of electrical power supply can cause minor personal injury or property damage if ig_ noted. nlust agree with motor nanmplate. 8 Ilse of fuses or wire smaller than size recommended in Tim word NOTICE indicates special instructions which are owner's manual can cause overheating, possible fires, and important but not related to hazards. will void warranty. l.To avoid risk of serious bodily injury and property dam-9. Pump water only with this pump. age, read safety instructions carefully before installing 10. Do not run pump dry. To do so will damage seals and can pump. cause leaking and property damage. PREPARATION BASIC TOOLS AND MATERIALS NEEDED Pipe Wrenches Screwdriver Hacksaw Check Valve Adjustable Wrench Teflon Tape Knife NOTICE: Depth to water must not be more than 20'. 1. Long runs and many fittings increase friction and reduce flow. Locate pump as close to water source as possible: use as few elbows and fittings as possible. 2. Be sure water is clear of sand. Sand will plug the pump and void the wa...
Other models in this manual:Water and Air Pumps - HYDROGLASS 390.262454 (477.44 kb)
Water and Air Pumps - HYDROGLASS 390.262553 (477.44 kb)