Login:
Votes - 4, Average rating: 3 ( )

User manual Pentair, model XLS800

Manafacture: Pentair
File size: 422.14 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Test the supply volt- floor drain vacuum valves to provide maximum flow. age, amperage draw, wire size against factory specifications and local codes. Test the operating refrigerant The auto vac manufacturer has a special valve that plugs pressures and corresponding components to factory into the skimmer before the auto vac hose. These spe specifications. Adjust refrigerant according to the sub cial valves will properly regulate the water flow through cooling reading and factory specification. the auto vac without creating too much vacuum restriction on the skimmer suction port. Clean and flush the evaporator coils to remove debris, salt and mineral build up at least twice a year. Clean The hose connecting the auto vac to the skimmer should more often if you live in a costal and or sandy environ be checked for the presence of suction leaks that allow ment. Clean them with a mild soap and a very soft air into the system. (See damage caused by vacuum brush. Do not use a pressurized garden hose. The air leaks previously). As the auto vac hose gets older and handling compartment below the fan must be cleaned sun damaged, it may develop an air vacuum leak or of debris regularly. Contact an air conditioning con- known as a "suction leak". tractor for proper methods of cleaning the evaporator coils. Remember to make sure the irrigation sprinkler In all cases, you should do what ever necessary to gain system does not spray on the unit! the proper water flow through the heat exchanger. Once the pool vac is working, make sure you have the proper The fan motor should be oiled when the unit is serviced water flow through the heater at all times. If the low otherwise once per year or more if needed. Coastal in flow created by an auto vac is causing a problem with stallation should oil the fan motor 4 times per year or the unit, it is not considered a warranty condition. more depending on exposure. 17 FOR PUMPS UP TO 2 H.P. OR 90 G.P.M. MAX. SEE PAGE 19 FOR LARGER WATER PUMPS. Water Pump Filter Chlorinator or Heater Chlorinator Loop & 2 lb. Chem. Resistant Check Valve WATER IN WATER OUT 4. LOOP & CHECK 5. CHLORINATOR 6. RETURN TO POOL Warning No Chemicals In Skimmer !! FOR PUMPS UP TO 2 H.P. OR 90 G.P.M. MAX. SEE PAGE 19 FOR LARGER WATER PUMPS. Water Pump Filter Chlorinator or Heater Chlorinator Loop & 2 lb. Chem. Resistant Check Valve WATER IN WATER OUT 4. LOOP & CHECK 5. CHLORINATOR 6. RETURN TO POOL Warning No Chemicals In Skimmer !! PLUMBING & WATER FLOW PLUMBING CONNECTIONS Filtered Water “IN” on the LEFT front. Heated Water "OUT" on the RIGHT front. The plumbing inlets are "slip" p.v.c. pipe that will accept a 2 inch p.v.c. glue fitting. The pipe is left plain so you can adapt to your needs. Use p.v.c. cleaner to prime the fitting and pipe. Use a quality medium body p.v.c. glue. 1. PUMP 2. FILTER 3. HEATER WARNING See mandatory chlorinator placement Chemical Feeder and install of the loop & check valve. INTERNAL AUTOMATIC BYPASS The heat pump in equipped with a internal "Automatic Bypass" valve. A variable rate spring valve is used to regulate the water flow through the heat exchanger. Steady flow will be delivered over a wide range of flow rates. This automatic valve can handle a maximum flow rate of 90 gallons per minute. The automatic valve will compensate for flow loss due to normal filter debris accumulation or changes if flow due to valving and other conditions. See chlorinator IN placement guidelines. Automatic Bypass Valve Variable Rate Self Adjusting up to 90 G.P.M. OUT Free Flow Marine Grade Flexible Cupronickel Water Inlets Heat Exchanger Encased in Closed Cell Foam Special Compression Fitting Sacrificial Chemical Protection Piping HIGH RATE WATER PUMPS Exercise care when installing chemical feeders so as not to allow back siphoning of chemicals into the heater, filters or pump. CAUTION The chemical resistant check valve and loop must be installed with all types of chlorinators to prevent chlorine migration to the heater. The loop should extend at least 8 inches above the chlorinator top. The chemical resistant check valve should be placed on the pipe leading "up" to the chlorinator. Therefore, the weight of the water above the check valve will hold it closed even if the spring is weak or damaged. Mount it as low as possible. Be sure to keep the chlorinator, pump and filter lid o-rings lubricated with silicone grease to insure a good seal. If it looses its seal, it will allow the chlorine to migrate to the heater when the system shuts off. The loss of vacuum allows reverse flow. 19 8" 2 LB CHEMICAL RESISTANT CHECK VALVE Part# 888-018 LOOP ABOVE CHLORI- NATOR FROM HEATER TO POOL EXCESSIVE FLOW BYPASS MANIFOLD FOR LARGE 2 H.P. PUMPS OR OVER 90 G.P.M. If the pool circulation pump is over 2 HP OR if the total flow exceeds 90 GPM you will have to add the "excessive flow valve" as shown here. Do not install a bypass valve that will completely shut off flow to the heater, see shutdown procedures. Some larger wa...

Other models in this manual:
Water and Air Pumps - HP 400, HP 600, HP 800, HP 1000, HP 230 (422.14 kb)
Water and Air Pumps - XLS600 (422.14 kb)
Water and Air Pumps - MiniMax Plus CP12 (422.14 kb)
Water and Air Pumps - MiniMax Plus XLS1000 (422.14 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category