Login:
Votes - 3, Average rating: 3.7 ( )

User manual Campbell Hausfeld, model AC1-8E

Manafacture: Campbell Hausfeld
File size: 2.53 mb
File name:
Language of manual:enfr
Free link for this manual available at the bottom of the page



manual abstract


Do not use a damaged extension cord. 5. Keep cords away from heat and sharp edges. Do not pull on a cord to disconnect a plug -- grasp the plug. 6. Always shut off the compressor Pressure Switch before unplugging the compressor. PRE-START CHECKLIST: 1. Check oil level. Add if necessary. 2. Remove any moisture in the air compressor air tank. NEVER attemptto open the Air Tank Drain Valve when more than 10 PSI of air pressure is in the air tank! Remove excessive pressure with an air tool, then open the Air Tank Drain Valve in the bottom of the air tank. Close tightly when drained. 3. Make sure the Motor/Pressure Switch is in the "OFF" position. 4. Make sure the Safety Relief Valve is working correctly. 5. Make sure all guards and covers are in place and securely mounted. DANGER RISK OF ELECTROCUTION! Improper connection of the equipment-groundingconductor can result in a risk of shock or electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not use any type of adapter with this product. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the WARNING RISK OF ELECTRICAL SHOCK! Thisproductmustbegrounded.If there should be a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding type plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded inaccordancewithalllocalcodes and ordinances. WARNING RISK OF BODILY INJURY! Never attempt to open the Air Tank Drain Valve when more than 10 PSI of air pressure is in the air tank! Portable Electric Air Compressor Manual OPERATING INSTRUCTIONS START-UP: 1. Read safety warnings before performing operation. 2. Ensure the Motor/Pressure Switch is in the "OFF" position. 3. Plug the Power Cord into a grounded outlet. 4. Move the Motor/Pressure Switch to the "AUTO" position. AX- OPTION: Locate the adjustment knob at the top of the Pilot Valve. -Turn it completely clockwise to the fully closed position. This will allow the air compressor to start building up pressure in the air tanks and stop when correct pressure is achieved. When pressure drops with usage, the air compressor will start building up pressure again. -Turn it completely counterclockwise to the fully open position. The air compressor is now set up to "CONSTANTLY" build up pressure. When pressure reaches the preset level in the air tank, pressure will bleed through the Pilot Valve. 5. Set pressure by adjusting the Pressure Regulator counterclockwise forless pressure and clockwise for more pressure. 6. If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting". SHUTDOWN: 1. To stop the air compressor, move the Motor/Pressure Switch to the "OFF" position. NEVER stop the air compressor by unplugging it from thepower source. This could result in risk of electrocution. 2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the Safety Relief Valve. 3. Once the Air Tank Pressure Gauge registers under 10 pounds, open the Air Tank Drain Valve under each air tank to drain any moisture. 4. Allow the air compressor to cool down. 5. Wipe the air compressor clean and store in a safe, non-freezing area. Portable Electric Air Compressor Manual MAINTENANCE INSTRUCTIONS Read the instruction manual before performing maintenance. The following procedures must be performed when stopping the air compressor for maintenance or service. 1. Turn off air compressor. 2. Disconnect Power Cord from main power supply. 3. Open all drains. 4. Wait for the air compressor to cool before starting service. AC Ele. Maintenance Chart WARNING RISK OF BODILY INJURY! Never assume the air compressoris safe to work on just because it is not operating. It could restart at any time! MAINTENANCE CHART PROCEDURE DAILY WEEKLY MONTHLY 200 HOURS Check pump oil level X Oil leak inspection X Drain condensation in air tank (s) X Inspect guards/covers X Check for unusual noise/vibration X Check for air leaks X Clean exterior of compressor X Inspect air filter X Inspect belt X Check safety relief valve X Change pump oil * X Replace air filter X *The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever comes first. Every two years, an Authorized Service Technician should check the check valve, intake valves and delivery valves. Portable Electric Air Compressor Manual TROUBLESHOOTING SYMPTOM PROBABLE CAUSE REMEDY Air compressor will not start. Air compressor will not start, but motor hums, then stops. Power Cord not plugged in. Motor/Pressure Switch turned "OFF". Motor Thermal Overload trippe...

Other models in this manual:
Water and Air Pumps - AC1-20E (2.53 mb)
Water and Air Pumps - AC1-20E (2.53 mb)
Water and Air Pumps - AC2-8E (2.53 mb)
Water and Air Pumps - AC2-20E (2.53 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category