|
manual abstract
of children and other untrained persons. Electrically-powered products are dangerous in the hands of untrained users. Check for misalignment or binding 3. of moving parts, breakage of parts, and any other condition that may affect this product’s operation. If damaged, have the Sump Pump serviced before using. Many accidents are caused by poorly maintained equipment. SERVICE Service must be performed only by 1. qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. When servicing this product, use 2. only identical replacement parts. Follow instructions in the “Inspection, Maintenance, And Cleaning” section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury. SPECIFIC SAFETY RULES Maintain labels and nameplates on 1. the Pump. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement. 2. Wear ANSI-approved safety impact eye goggles when assembling the Pump. Using personal safety devices reduce the risk for injury. Safety impact eye goggles are available from Harbor Freight Tools. Use the right product for the job. 3. There are certain applications for which this product was designed. Do not use small tools, attachments, or equipment to do the work of larger industrial tools, attachments, or equipment. Maintain a safe environment. 4. Keep the area well lit. Make sure there is adequate surrounding space. Always keep the area free of obstructions, grease, oil, trash, and other debris. Do not use an electrically powered product in areas near flammable chemicals, dusts, and vapors. 5. Risk of electrical shock. Always disconnect the Pump from its power source before handling or making any adjustments to the tool. Always wear non-skid rubber boots when water is on the floor and you must unplug the Pump. Make sure the electrical power source is a separately fused, grounded, 3-wire type GFCI (Ground Fault Circuit Interrupter) outlet. Do not remove the ground prong on the Power Cord Plug. Do not use an extension cord. Do not pump hazardous materials. 6. Do not pump explosive or flammable materials such as fuel, oil, kerosene, gasoline, etc. Do not pump in close proximity to flammable or explosive materials. Do not pump fats, oils, salt or waste water. This Pump is designed to move clean or dirty water only. Do not pump water hotter than 95 degrees Fahrenheit. Secure the discharge pipe 7. (not included) to a solid surface to ensure the stability of the Pump. Position the Pump on a flat, level, 8. solid surface. OUTLETDEVICECORDDrip Loop 9. Arrange a “drip loop” in the Power Cord connecting the Pump to a 115 volt, GFCI electrical outlet. A drip loop is that part of the Power Cord below the level of the outlet to prevent water from traveling along the Power Cord and coming in contact with the outlet. If the Power Plug or electrical outlet does get wet, do not unplug the Power Cord. Disconnect the fuse or circuit breaker that supplies power to the Pump. Then, unplug the Power Cord and examine for presence of water in the outlet. If necessary,10. have a certified electrician install (within 10 feet of where the Pump will be located) a 115 volt, GFCI electrical outlet that is dedicated only to the Pump. Any outlet should be above the water line. NEVER raise or lower the Pump by 11. its electrical Power Cord. In cold weather, when the Pump 12. is not in use, protect the interior of the Pump from freezing by draining the water and pumping a permanent type automobile anti- freeze containing a rust inhibitor through the system. A 50% mixture with water is recommended. Be sure to flush the system with a neutralizing liquid prior to re-use of the Pump. If an extension cord is used (for 13. temporary use only) connections must not come in contact with water or any wet surfaces. Prior to use, and periodically 14. thereafter, check to make sure all connections are tight and secure. Industrial applications must follow 15. OSHA requirements. People with pacemakers should 16. consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure. The warnings and cautions dis17. cussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. Grounding To prevent electric shock and death from incorrect grounding wire connection: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit th...
Other models in this manual:Water and Air Pumps - 95591 (997.36 kb)
Water and Air Pumps - 95593 (997.36 kb)