|
manual abstract
To continue pumping, turn on the unit’s power. The display returns to the STOPPED Display Mode and shows the current RPM setting. The accumulated time of pumping and volume dispensed is reset to zero. Then press the START/STOP key. START STOP xxx rpm Pump(s) stops; press again pump(s) starts To resume pumping at the current setting, press the START/STOP key. The display enters the RUNNING Display Mode, and the fluid begins to dispense. INLET SELECT Must STOP first! LEDs indicate new pump direction To select the other inlet and reverse the direction of pumping: 1. Press the START/STOP key. The display returns to the STOPPED Display Mode. 2. Press the INLET SELECT key to reverse the direction of pumping. 3. Press the START/STOP key again to resume pumping. 4. For detailed instructions on “Defining the Direction of Pumping, refer to Section 5.2. PRIME STOP to Prime... Pumps fluid at current RPM setting as long as the key is pressed To prime a tube: 1. Press the START/STOP key to stop the pump. The display returns to the STOPPED Display Mode. 2. Press and hold down the PRIME key to prime the tube. 3. Press the START/STOP key again to resume pumping. 4. For detailed instructions on “Priming a Tube”, refer to Section 5.4. TEMP xxx °C Display alternates when pressed, °C then °F NOTE: The TEMP key functions the same whether the pump is stopped or running. Refer to Section 5.6. RPM xxx rpm Displays current RPM setting 1. Press the RPM key. The display flashes the RPM setting you selected just before starting the pump. 2. Use the UP and DOWN ARROW keys to enter the RPM setting you desire. As you use the UP and DOWN ARROW keys, the display changes accordingly. TIME xx:xx:xx Displays cumulative TIME since start Press the TIME key. The display flashes the time that the pump has been running (xx:xx:xx). Table 6-1 (cont’d) RPM MODE KEY DISPLAY SHOWS ACTION TAKEN AND PROCEDURE FLOW RATE xxx mL/min or xxx Liter/min Displays actual FLOW RATE Press the FLOW RATE key. The display flashes the fluid flow rate calculated for the RPM setting previously selected (xxx mL/min or xxx L/min). TOTAL VOLUME xxx mL or xxx Liters Displays current TOTAL VOLUME 1. Press the TOTAL VOLUME key. The display flashes the calculated volume of fluid dispensed since the pump started running (xxx mL or xxx Liters). TUBE ID TUBE ID=xxx Displays current TUBE ID Press the TUBE ID key. If the red LED next to the CALIBRATE key is not lit, the display flashes the current TUBE ID setting. If the red LED next to the CALIBRATE key is lit, the display flashes the message “CALIBRATED TUBE!”. CALIBRATE CALIBRATED! or not calibrated Displays calibration state 1. Press the CALIBRATE key. If the red LED next to the CALIBRATE key is not lit, the display shows “not calibrated”.. If the red LED next to the CALIBRATE key is lit, the display shows “CALIBRATED!”. To calibrate a tube: 2. Press the START/STOP key to stop the pump. The display returns to the STOPPED Display Mode. For detailed instructions on “Calibrating a Tube”, refer to Section 5.5. and xxx rpm NOTE: if you press the UP and DOWN ARROW keys, the display shows the current RPM setting. This setting changes accordingly as you use the UP and DOWN ARROW keys but does not wrap around at 10 RPM and 600 RPM while the pump is running. Refer to Figure 6-2. Language Button NOTE: if you press the Language button, the display changes to the next language in the sequence: English, French, Spanish, German, and Italian. Operating the Pump Motor in the RUNNING Display Mode 6 6.2 The FLOW RATE Mode Figure 6-3 shows the overall block diagram of the FLOW RATE Mode in the RUNNING Display Mode. STOPPED DISPLAY MODE OR TUBE ID SETTING TO BE USED IN PUMPING OR CURRENT TUBE ID SETTING RUNNING DISPLAY MODE START STOP FLOW RATE TUBE ID CURRENT FLOW RATE SETTING FLOW RATE SETTING TO BE USED IN PUMPING CALCULATED FLOW RATE START STOP (Optional) CALIBRATE (Refer to Section 5.5) Figure 6-3. Block Diagram: Pumping in the FLOW RATE Mode In the FLOW RATE Mode, you pump fluid at a certain flow rate, without setting the amount of time you pump or the amount of fluid you dispense. The pump motor measures the time of pumping and volume of fluid dispensed but ignores the TIME and TOTAL VOLUME settings. 6.2.1 Pumping in the FLOW RATE Mode To pump fluid in the FLOW RATE Mode, do the following: 1. Set up the pump motor for pumping, according to Chapter 3. 2. Toggle the ON/OFF switch to turn on the unit’s power. The display is in the STOPPED Display Mode. Refer to Figure 6-3. 3. Either set the TUBE ID for the tube you are using (following Section 5.3) or calibrate the tube (following Section 5.5), before continuing. 4. Press the FLOW RATE key. FLOW RATE Display shows xxx mL/min ACTION Displays current FLOW RATE setting The display flashes the current FLOW RATE setting (xxx mL/min or xxx L/min). Operating the Pump Motor in the RUNNING Display Mode 6 5. Use the UP and DOWN ARROW keys to enter the FLOW RATE setting you desire. xxx mL/min ACTION FLOW ...
Other models in this manual:Water and Air Pumps - FPU5-MT-220 (1.26 mb)