manual abstract


• Format STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0000nnnn 0n n=0-15 (Device number=Device No-1) FORMAT No. 01111110 7E Universal bulk dump COUNT HIGH 00000000 00 data count = ch(0x00) * 128 + cl(0x72) = 114 COUNT LOW 01110010 72 01001100 4C ‘L’ 01001101 4D ‘M’ 00100000 20 ‘ ’ 00100000 20 ‘ ’ 00111000 38 ‘8’ 01000100 44 ‘D’ 00110001 31 ‘1’ 00110001 31 ‘1’ DATA NAME 01000101 45 ‘E’ 0mmmmmmm mh 0-220(Program no.P1-97,C125, U1-99),256(EDIT BUFFER) 0mmmmmmm ml BLOCK INFO. 0ttttttt tt total block number(minimum number is 0) 0bbbbbbb bb current block number(0-total block number) DATA 0ddddddd ds Effect Program data of block[bb] : : 0ddddddd de CHECK SUM 0eeeeeee ee ee=(Invert(‘L’+...de) +1)&0x7F EOX 11110111 F7 End of exclusive The second and third byte of DATA NAME specify the program number. 0:PRESET1 – 96:PRESET97 97:CLASSIC1 – 121:CLASSIC25 122:USER1 – 220:USER99 256:EDIT BUFFER For reception by the SPX2000, only USER 1-99 or EDIT BUFFER are valid. (120-220, 256) ¦ 2.8.1.4 Effect Program Bulk Dump request Format The second and third byte of DATA NAME specify the program number. • Format STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0010nnnn 2n n=0-15 (Device number=Device No-1) FORMAT No. 01111110 7E Universal bulk dump 01001100 4C ‘L’ 01001101 4D ‘M’ 00100000 20 ‘ ’ 00100000 20 ‘ ’ 00111000 38 ‘8’ 01000100 44 ‘D’ 00110001 31 ‘1’ 00110001 31 ‘1’ DATA NAME 01000101 45 ‘E’ 0mmmmmmm mh 0-220(Program no.P1-97,C125, U1-99), 256(EDIT BUFFER) 0mmmmmmm ml EOX 11110111 F7 End of exclusive The second and third byte of DATA NAME specify the program number. 122:USER1 – 220:USER99 256:EDIT BUFFER ¦ 2.8.1.5 Program change table Bulk Dump Format This bulk-dumps the program change table data. • Format STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0000nnnn 0n n=0-15 (Device number=Device No-1) FORMAT No. 01111110 7E Universal bulk dump COUNT HIGH 0ccccccc ch data count = ch * 128 + cl COUNT LOW 0ccccccc cl 01001100 4C ‘L’ 01001101 4D ‘M’ 00100000 20 ‘ ’ 00100000 20 ‘ ’ 00111000 38 ‘8’ 01000100 44 ‘D’ 00110001 31 ‘1’ 00110001 31 ‘1’ DATA NAME 01010000 50 ‘P’ 00000010 02 00000000 00 No.256 = Current BLOCK INFO. 0ttttttt tt total block number (minimum number is 0) 0bbbbbbb bb current block number (0 - total block number) DATA 0ddddddd ds Program change table data of block[bb] : : 0ddddddd de CHECK SUM 0eeeeeee ee ee=(Invert (‘L’+...+de)+1) &0x7F EOX 11110111 F7 End of exclusive ¦ 2.8.1.6 Program change table Bulk Dump request Format • Format STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0010nnnn 2n n=0-15 (Device number=Device No-1) FORMAT No. 01111110 7E Universal bulk dump 01001100 4C ‘L’ 01001101 4D ‘M’ 00100000 20 ‘ ’ 00100000 20 ‘ ’ 00111000 38 ‘8’ 01000100 44 ‘D’ 00110001 31 ‘1’ 00110001 31 ‘1’ DATA NAME 01010000 50 ‘P’ 00000010 02 00000000 00 No.256 = Current EOX 11110111 F7 End of exclusive ¦ 2.8.2 Program change table Bulk Dump request Format When the SPX2000 receives a Parameter Change message, the SPX2000 setting specified by the content will be controlled. When the SPX2000 receives a Parameter Change Request message, it will transmit a Parameter Change message in reply. • Reception conditions This message is received if the following two conditions are satisfied. 1) The “MIDI RECEIVE” setting (Seite 23) is “SYEX PRMCHG = ON”. 2) The device number within the MIDI message matches the SPX2000’s MIDI channel, or the SPX2000’s MIDI channel is set to OMNI. •Transmission conditions PARAMETER CHANGE only This message is transmitted when either of the following conditions are met. •The SPX2000’s state has changed due to a received Parameter Change •A Parameter Change Request message is received ¦ 2.8.2.1 Parameter change (Edit Buffer) This message modifies the value of a parameter in the edit buffer. • Format STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=Device No-1) GROUP ID 00011110 1E MODEL ID (signal processor) MODEL ID 00001001 09 SPX2000 ADDRESS 00000001 01 Edit Buffer 0eeeeeee ee Element no.(if 'ee' is 0, 'ee' will be expanded to two bytes) 0ppppppp pp Parameter no. 0ccccccc cc Channel no. DATA 0ddddddd dd data : : EOX 11110111 F7 End of exclusive MIDI SPX2000—Bedienungsanleitung 91 ¦ ¦ • Format STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3n n=0-15 (Device number= Device No-1) GROUP ID 00011110 1E MODEL ID (signal processor) MODEL ID 00001001 09 SPX2000 ADDRESS 00000001 01 Edit Buffer 0eeeeeee ee Element no.(if 'ee' is 0, 'ee' will be expanded to two bytes) 0ppppppp pp Parameter no. 0ccccccc cc Channel no. EOX 11110111 F7 End of exclusive ¦ 2.8.2.3 Parameter change (System Setup Memory) This message modifies th...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category