|
Other manuals for this model:
manual abstract
[SW6] The System data can be transmitted/recognized in any mode. Regarding other types of data, it depends on the current mode whether they can be transmitted/recognized or not. In an exception to this, Normal Voice Parameter Changes can be also recognized in the Multi mode when the Normal Voice is assigned to the current Part in the Multi Voice Edit mode (except for the parameters that duplicate the Multi data). [SW7] SYSTEM Bank Select Switch [SW8] SYSTEM Program Change Switch (Among the Play modes, this message can be recognized only in the Voice Mode.) [SW9] SYSTEM Bulk Protect and same as SW6. The User Voice, User Performance, and User Multi data can be transmitted/recognized in any mode. In an exception to this, the bulk data of the Normal Voice can be also recognized in the Multi mode when the Normal Voice is assigned to the current Part in the Multi Voice Edit mode. [SW10] MIDI Receive Channel and Receive Filter In the Performance/Multi mode: complies with Part Receive Channel and Part Receive Switch. In the other mode: complies with Basic Receive Channel. [SW11] SYSTEM Receive GM/XG On *1: Performance Mode and Multi Mode *2: Available only for the Plug-in Voices *3: Recognized/transmitted only when the Plug-in Voice (MODEL ID = 0x64) is selected. However, specific parameter blocks (Common, Plug-in XG Part, and Native) cannot recognize Parameter Change messages. (3) TRANSMIT/RECEIVE DATA (3-1) CHANNEL VOICE MESSAGES (3-1-1) NOTE OFF STATUS 1000nnnn(8nH) n = 0 - 15 CHANNEL NUMBER NOTE No. 0kkkkkkk k = 0 (C-2) - 127 (G8) VELOCITY 0vvvvvvv v: ignored Receive only (3-1-2) NOTE ON/OFF STATUS 1001nnnn(9nH) n = 0 - 15 CHANNEL NUMBER NOTE NUMBER 0kkkkkkk k = 0 (C-2) - 127 (G8) VELOCITY NOTE ON 0vvvvvvv(v.0) NOTE OFF 0vvvvvvv(v=0) (3-1-3) CONTROL CHANGE STATUS 1011nnnn(BnH) n = 0 - 15 CHANNEL NUMBER CONTROL NUMBER 0ccccccc CONTROL VALUE 0vvvvvvv *TRANSMITTED CONTROL NUMBER c = 0 BANK SEL MSB ; v = 0 - 127 *3 c = 32 BANK SEL LSB ; v = 0 - 127 *3 *RECEIVED CONTROL NUMBER c = 0 BANK SEL MSB ; v = 0 - 127 *3 c = 32 BANK SEL LSB ; v = 0 - 127 *3 c = 1 MODULATION ; v = 0 - 127 c = 5 PORTAMENTO TIME ; v = 0 - 127 *2 c = 6 DATA ENTRY MSB ; v = 0 - 127 *1 c = 38 DATA ENTRY LSB ; v = 0 - 127 *1 c = 7 MAIN VOLUME ; v = 0 - 127 c = 10 PAN ; v = 0 - 127 c = 11 EXPRESSION ; v = 0 - 127 c = 31 EG SUSTAIN LEVEL ; v = 0:-64 - 64:0 - 127:+63 *2,*5 c = 64 SUSTAIN SWITCH ; v = 0 - 63:OFF, 64 - 127:ON *2 c = 65 PORTAMENTO SWITCH ; v = 0 - 63:OFF, 64 - 127:ON *2 c = 66 SOSTENUTO ; v = 0 - 63:OFF, 64 - 127:ON *2 c = 71 HARMONIC CONTENT ; v = 0:-64 - 64:0 - 127:+63 c = 72 EG RELEASE TIME ; v = 0:-64 - 64:0 - 127:+63 *2 c = 73 EG ATTACK TIME ; v = 0:-64 - 64:0 - 127:+63 c = 74 BRIGHTNESS ; v = 0:-64 - 64:0 - 127:+63 c = 75 EG DECAY TIME ; v = 0:-64 - 64:0 - 127:+63 c = 91 EFFECT1 DEPTH ; v = 0 - 127 c = 93 EFFECT3 DEPTH ; v = 0 - 127 c = 96 DATA ENTRY INC ; v = 127 *1 c = 97 DATA ENTRY DEC ; v = 127 *1 c = 0..95 ASSIGNABLE CONTROLLER ; v = 0 - 127 *6 c = 0..95 ARPEGGIO SW ; v = 0 - 63:OFF, 64 - 127:ON *6 c = 0..95 ARPEGGIO HOLD ; v = 0 - 63:OFF, 64 - 127:ON *6 *1 Used only when a value is set using RPN. *2 Invalid with Drum Voices. *3 Relation between BANK CHANGE and PROGRAM is as follows: CATEGORY MSB LSB PROGRAM No. GM Voice 0 0 0..127(1..128) GM Drum Voice 127 0 0 (1) Normal Voice Preset 1 63 0 0..127(1..128) Preset 2 63 1 0..127(1..128) Preset 3 63 2 0..127(1..128) Preset 4 63 3 0..127(1..128) Preset 5 63 4 0..127(1..128) Preset 6 63 5 0..127(1..128) User 1 63 8 0..127(1..128) User 2 63 9 0..127(1..128) User 3 63 10 0..127(1..128) Drum Voice Preset 63 32 0..63 (1..64) User 63 40 0..31 (1..32) Plug-in Voice User 1 63 24 0..63 (1..64) User 2 63 25 0..63 (1..64) Plug-in Voice Preset 1 (Slot 1) 63 70 0..63 (1..64) *4 Preset 2 (Slot 1) 63 71 0..63 (1..64) *4 Preset 3 (Slot 1) 63 72 0..63 (1..64) *4 Preset 1 (Slot 2) 63 73 0..63 (1..64) *4 Preset 2 (Slot 2) 63 74 0..63 (1..64) *4 Preset 3 (Slot 2) 63 75 0..63 (1..64) *4 Performance User 63 64 0..127(1..128) Multi User 63 65 0..127(1..128) When switching the modes, MODE CHANGE must be transmitted to the instrument (3-6-3-2). *4 Can be selected only when the corresponding Plug-in Board has been installed. *5 Transmitted/received only when MODE 2 is selected in CONTROL CHANGE MODE. *6 The default CONTROL NUMBERs of ASSIGNABLE CONTROLLER are as follows: BREATH CONTROLLER 2 FOOT CONTROLLER 4 Assign 1 16 Assign 2 17 Assign A 18 Assign B 19 FOOT SWITCH 88 ARPEGGIO HOLD 89 ARPEGGIO SWITCH 90 PORTAMENTO TIME sets the time it takes for the pitch to reach the next note played when PORTAMENTO SWITCH is set to on. PAN position relatively changes according to the preset value for each Voice. EFFECT1 DEPTH controls reverb send level. EFFECT3 DEPTH controls chorus send level. HARMONIC CONTENT adjusts the resonance preset for each Voice. Setting a value adds to or subtracts from the center value, 64, since it is an offset parameter. The larger the value more resonant sound will be produced. The effect...