Manafacture: Yamaha
File size: 93.98 kb
File name:
|
Other manuals for this model:
manual abstract
The battery check indicator (BATT.) will light briefly when a plug is inserted or removed from the output jack. This is normal and does not indicate a malfunction. Be sure to remove the battery if the instrument will not be used for an extended period of time in order to prevent possible damage due to battery leakage. Battery HolderControl Section Bar Sensor NOMENCLATURE Output Jack (with power switch function) System SYSTEM-55TA: Monaural 1 way Pickup Bar Sensor (Piezo type) Pre-amplifier Controls VOL., 3 Band (HIGH, MID, LOW) EQ control, AMF control Output jack Combination end pin/power switch Output impedance 1 k. Power supply 9V DC, S-006P (6F22) dry cell battery Battery life Approx. 150 hours (without tuner) Approx. 140 hours (with the preamp switched ON and the tuner used 1 minute every 1 hour) Tuner Tuning System: Chromatic type (12 semitones), A4=440Hz Auto OFF Function: Tuner automatically switches OFF after 1 minute. Input: Built in pickup (bridge bar sensor) Accuracy: +/– 3 cents Accessories • Hexagonal wrench for neck adjustment x1 • S-006P (6F22) dry cell battery x1 THE CONTROLS wq e q VOL. (Volume) Control Adjusts the overall output volume level. * Make sure that the VOL. is turned to “0” before connecting or disconnecting. w BATT. (Battery Check) Indicator This indicator will light when the battery needs to be replaced. Please replace the battery as soon as possible when the BATT. indicator lights. e 3 Band Equalizer LOW : Boosts or cuts the level of the low frequencies. MID : Boosts or cuts the level of the middle frequencies. The AMF control r adjusts the center frequency of the band affected by this control. HIGH : Boosts or cuts the level of the high frequencies. r AMF Control Sets the center frequency of the band of frequencies affected by the MID equalizer control. The range is from 80 Hz to 10 kHz. * This control has no effect when the MID equalizer control is set to its center (“0”) position. t Tuner Switch Switches the tuner ON/OFF. y Tuner Display Displays tuner information. ytr BATTERY REPLACEMENT Be sure to replace the battery as soon as possible when the battery check USING THE TUNER indicator lights in order to avoid reduced sound quality. * Be sure to remove the battery if the instrument will not be used for an extended period of time in order to prevent possible damage due to battery leakage. q Press the catch on the battery holder in the direction indicated by the arrow in the illustration in order to unlock it. w Slide out the battery case. e Remove the old battery from the battery case, and insert the new battery making sure that the (+) and (–) terminals of the battery are positioned as shown in the illustration. Use only a DC9V, S-006P (6F22) or equivalent battery. r Slide the battery case back into the battery holder and press firmly so that the battery case locks into place. OPEN Catch DC9V S-006P (6F22) Battery case qOPEN w, rewr The guitar is equipped with an A4=440Hz standard pitch tuner. The tuner’s circu...
Other models in this manual:Musical Instruments - CPX500 (93.98 kb)