Login:
Votes - 5, Average rating: 3.2 ( )

User manual Yamaha, model EMX68S

Manafacture: Yamaha
File size: 1.96 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


However, please check the following three points to prevent the problem from recurring. • If the level setting is excessive, lower it to the nominal level.You can refer to the peak level indicators of the main section when doing so. • If the device is not ventilated sufficiently, refer to the cautions given at the beginning of this manual and take appropriate measures to insure adequate ventilation. • If the load impedance (including a short) is too low, refer to the chapter on connections (page 15) and change the connections so that the impedance is correct. Other Connections between devices have come loose. Inspect the connections, and correct any faulty connections. Other The device may have malfunctioned. Please contact your dealer. Powered Mixer Q&A Q: The built-in effect is not effective. A: The ON switch in the DIGITAL EFFECT section may not be turned on. Or, you have adjusted the EFFECT control in the Channel section or the EFFECT RTN control in the MAIN section. Q: The monitoring sound from the speakers is not power-A: The equalizer LOW control for each channel may be set ful enough relative to the level of the input sound. to negative values. Q: The signal is sent from the EFFECT OUT jack to the A: The AUX IN control in the MAIN section may not be connected effect processor. Then the effect sound is rotated to right. returned to the AUX IN jack. However, no signal is input to the mixer. Q: An external powered speaker is connected to the MON-A: The MONITOR controls for input channels may not ITOR-OUTPUT jack. have been adjusted. However, the signal is not sent to the speaker even when the MASTER control in the MONITOR section is turned. Q: Can the Low-Z jack and the Hi-Z jack be used at the A: You cannot use the Low-Z jack and the Hi-Z jack for the same time? same channel at the same time. Q: Can a single speaker be connected to the mixer? A: Yes. Use a speaker with an impedance of 4-8 ohms. EMX88S/EMX68S—Owner’s Manual Specifications 27 Specifications 27 General specifications Maximum output power MAIN L, R: 400 W+400 W/4. @0.5% THD at 1 kHz, 270 W+270 W/8. @0.5% THD at 1 kHz MAIN BRIDGE: 800 W/8. @0.5% THD at 1 kHz Frequency response 20 Hz–20 kHz +1 dB, –3 dB @1 W output into 8. (SPEAKERS OUT) 20 Hz–20 kHz +1 dB, –3 dB @+4 dB output into 10 k. (MAIN OUT, MONITOR OUT, EFFECT OUT) Total harmonic distortion Less than 0.5% @20 Hz–20 kHz, 200 W output into 4. (SPEAKERS OUT) Less than 0.3% @20 Hz–20 kHz, +14 dB output into 10 k. (MAIN OUT, MONITOR OUT, EFFECT OUT) Hum & noise (Average, Rs=150.) (with 20 Hz–20 kHz BPF) –124 dB equivalent input noise, –65 dB residual output noise (SPEAKERS OUT) –88 dB residual output noise (MAIN OUT, MONITOR OUT) –79 dB (MAIN OUT) Master level control: nominal level, All channel level controls: minimum –75 dB (MONITOR OUT) Master level control: nominal level, All channel level controls: minimum –69 dB (MAIN OUT) Master level control: nominal level, 1 channel level control: nominal level –84 dB (EFFECT OUT) All channel level controls: minimum –64 dB (EFFECT OUT) 1 channel level control: nominal level Maximum voltage gain 86 dB CH IN (Lo-Z) to SPEAKERS OUT 66 dB CH IN (Lo-Z) to MAIN OUT, MONITOR OUT 66 dB CH IN (Lo-Z) to EFFECT OUT 48 dB CH IN (Lo-Z) to REC OUT 56 dB CH IN (Hi-Z) to MAIN OUT, MONITOR OUT 46 dB CH IN (Super Hi-Z) to MAIN OUT 26 dB AUX IN to MAIN OUT 24 dB 2TR IN to MAIN OUT 66 dB MIC IN to MAIN OUT 26 dB LINE IN to MAIN OUT Crosstalk at 1 kHz 65 dB adjacent input, 65 dB input to output Input channel equalization ±15 dB Maximum HIGH 10 kHz shelving MID 2.5 kHz peaking LOW 100 Hz shelving * Turn over/roll-off frequency of shelving: 3 dB below maximum variable level. Meters 5 POINTS LED METER (MAIN OUT L/R, MONITOR OUT) Graphic equalizer 7 bands (125, 250, 500, 1k, 2k, 4k, 8k Hz) ±12 dB Maximum (MAIN OUT, MONITOR OUT) Internal digital effect 16 programs, parameter control, tap delay control Phantom power +15 V (balanced input) Limiter Comp. : THD.0.5% (SPEAKERS OUT) LIMIT indicators Turns on. : THD.0.5% (SPEAKERS OUT) Protection circuit (Power amp) POWER switch on/off mute, DC detection, TEMP (heatsink temp. .90°C) Fan circuit stop — low speed (50°C) — variable — high speed (70°C) Foot switch (FC5) DIGITAL EFFECT MUTE : on/off, Tap delay Optional accessories RK-88, FC5 Power requirement/ Power consumption USA and Canada 120 V AC 60 Hz/300W Europe 230 V AC 50 Hz/350W Other 240 V AC 50 Hz/350W Dimensions (WxHxD) 482.305.328 mm Weight 15.5 kg Supplied accessories AC power cord, Owner’s Manual EMX88S/EMX68S—Owner’s Manual 28 Specifications 28 Specifications Input specifications Input connectors PAD Actual load impedance Nominal impedance Input level Connector typeSensitivity*1 Nominal level Max. before clipping CH INPUT (Low-Z) (CH1–4/1–6) OFF 3 k. 50–600. Mics –62 dB (0.616 mV) –50 dB (2.45 mV) –20 dB (77.5 mV) XLR-3-31 type*2ON 600. Lines –32 dB (19.5 mV) –20 dB (77.5 mV) +10 dB (2.45 V) CH INPUT (Hi-Z) (CH1–2/1–4) OFF 10 k. 50–600. Mics –52 dB (1.95 mV) –40 dB...

Other models in this manual:
Musical Instruments - EMX88S (1.96 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category