Login:
Votes - 0, Average rating: 5 ( )

User manual Yamaha, model PM1DV2

Manafacture: Yamaha
File size: 403.08 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


If there is a combination of different versions, or if any component has malfunctioned, the VERSION CHECK popup window will appear when the CS1D starts up. This will not appear if all components are correct. This version check function is explained below. 3 4 5 1 2 6 7 8 K9 J A Checking result message field B OK button (may not be displayed in some cases) C PM1D SYSTEM SOFTWARE version display field D CS1D screen software version display field E CS1D firmware version display field F ENGINE A DSP1D(-EX) firmware version display field G ENGINE A INPUT UNIT firmware version display field H ENGINE A OUTPUT UNIT firmware version display field I ENGINE B DSP1D(-EX) firmware version display field J ENGINE B INPUT UNIT firmware version display field K ENGINE B OUTPUT UNIT firmware version display field Version display fields 4through Kconvey the following information. L NM L Component name or firmware name M Firmware version display field for L N Result of test Of these fields, lines displayed in white characters indicate the version of that entire component. Lines displayed in smaller characters of gray provide details on firmware versions of individual CPUs within the component. Of these, fields Mand Nmay be of the following types. • Field Mdisplay list x.xx (numeric) Firmware version NO REPLY CPU within the component does not respond -------Board not installed in the DSP1D(-EX) DIFF. Board is incorrectly inserted in the DSP1D(-EX) • Field Ndisplay list OK Normal ---Not connected (normal) NG Illegal firmware version within the component or no response from CPU within the component OLD Old version NEW New version DIFF Illegal combination of versions The above test results are summarized, and a message is shown in 1. If this popup window appears, refer to the following explanation and resolve the reason for the problem. [Results other than OK] If there is a problem with other than the firmware that operates the controls of the CS1D and the INPUT UNIT / OUTPUT UNIT, the OK button 2will not appear. In this case, it will be impossible to perform any screen operations or use any of the controls, and thus impossible to control the system. Since correct operation cannot be guaranteed in such a state, please remove the cause of the problem. The system will not recover until the cause is removed. If there is a problem with the firmware that operates the controls of the CS1D and the INPUT UNIT / OUTPUT UNIT, the OK button 2will appear. Click the OK button, and the system will forcibly be started up, ignoring the faulty component or faulty portion of the component. At this time, a popup window will appear to inform you which component is being ignored, and the following limitations will apply. However, the correctly functioning components will operate, allowing you to control the remaining portions of the system. PM1D V2 System Software Installation Guide 3 Only that unit is muted, and will not be INPUT UNIT not OK controllable Only that unit is muted, and will not be OUTPUT UNIT not OK controllable CONSOLE section INPUT01-12 not OK INPUT block (CS1D lower left) inoperable INPUT13-24 not OK INPUT block (CS1D upper left) inoperable INPUT25-36 not OK INPUT block (CS1D lower right) inoperable INPUT37-48 not OK INPUT block (CS1D upper right) inoperable INSEL not OK SELECTED INPUT CHANNEL block inoperable MAS1 not OK MIX OUTPUT / DCA GROUP block inoperable MAS2 not OK MIX OUTPUT / DCA GROUP block inoperable OUTSEL not OK SELECTED OUTPUT CHANNEL block, SCENE MEMORY block, MASTER block, LCD FUNCTION ACCESS block, USER DEFINE block, STEREO OUTPUT block, Data entry block (except for track pad and left/right switches) inoperable METER not OK METER BRIDGE block will not function The system will recover from these limitations when you remove the cause of the problem and turn on the power of the CS1D once again. Updating the firmware (CS1D/ DSP1D(-EX)/AI8/AO8/DIO8) You will use the PM1DLOAD software to update the firmware of each component. The basic procedure and the update method for each firmware is explained below. [Explanation of each screen in PM1DLOAD] Mode Select screen 2 1 A “Write via serial port” mode You must select this. B “Write board directly” mode Do not select this. Main screen 3 78 4 6 5 9 J K L NOTE: • These problems can normally be solved by executing the system update described below. However, if problems remain after this is done, please contact Yamaha service. • If there is a problem with a unit, please check whether there is a faulty connection for the D-Sub half-pitch 68-pin cable. The unit will not function correctly if a pin is bent or not inserted. System update procedure When updating the system, you must perform the update and installation for all components. Using the procedure described below, perform the firmware update and the CS1D screen software update. Scene data etc. that you created using this system must be backed up on a memory card before you perform the update. The internal data will be lost whe...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category