Login:
Votes - , Average rating: ( )

User manual Yamaha, model DM1000

Manafacture: Yamaha
File size: 7.8 mb
File name:

Language of manual:ende

The document is loading, please wait
The document is loading, please wait


Other manuals for this model:

manual abstract


DATA FORMAT 1.1 CHANNEL MESSAGE Command rx/tx function 8n NOTE OFF rx Control the internal effects 9n NOTE ON rx Control the internal effects Bn CONTROL CHANGE rx/tx Control parameters Cn PROGRAM CHANGE rx/tx Switch scene memories Command rx/tx function F0 43 1n 3E 0C … F7 RARAMETER CHANGE F0 43 3n 3E 0C … F7 PARAMETER REQUEST F0 43 1n 3E 7F … F7 PARAMETER CHANGE F0 43 3n 3E 7F … F7 PARAMETER REQUEST rx/tx rx/tx rx/tx rx/tx DM1000-specific parameter change DM1000-specific parameter change General purpose digital mixer parameter change General purpose digital mixer parameter request The following data types of parameter change are used by the DM1000. 1.2 SYSTEM COMMON MESSAGE Command rx/tx function F1 MIDI TIME CODE QUARTER rx MTC FRAME F2 SONG POSITION POINTER rx Used when TIME REFERENCE is MIDI CLOCK. 1.3 SYSTEM REALTIME MESSAGE Command rx/tx function F8 TIMING CLOCK rx MIDI clock FA START rx Start automix (from the beginning) FB CONTINUE rx Start automix (from the middle) FC STOP rx Stop automix FE ACTIVE SENSING rx Check MIDI cable connections FF RESET rx Clear running status 1.4 EXCLUSIVE MESSAGE 1.4.1 Real Time System Exclusive Command rx/tx function F0 7F dd 06 … F7 MMC tx MMC command COMMAND F0 7F dd 07 … F7 MMC RESPONSE rx MMC response F0 7F dd 01 … F7 MIDI TIME CODE rx MTC full message 1.4.2 System Exclusive Message 1.4.2.1 Bulk Dump Command rx/tx function F0 43 0n 7E … F7 BULK DUMP rx/tx BULK DUMP DATA DATA F0 43 2n 7E … F7 BULK DUMP rx/tx BULK DUMP REQUEST REQUEST The following data types of bulk dump are used on the DM1000. Data name tx/rx function ‘m’ tx/rx Scene Memory & Request (compressed data) ‘S’ tx/rx Setup Memory & Request ‘L’ tx/rx User defined MIDI remote & Request ‘V’ tx/rx User defined keys & Request ‘U’ tx/rx User assignable layer & Request ‘C’ tx/rx Control change table & Request ‘P’ tx/rx Program change table & Request ‘Q’ tx/rx Equalizer library & Request ‘Y’ tx/rx Compressor library & Request ‘G’ tx/rx Gate library & Request ‘E’ tx/rx Effect library & Request ‘H’ tx/rx Channel library & Request ‘R’ tx/rx Input patch library & Request ‘O’ tx/rx Output patch library & Request ‘J’ tx/rx Bus to Stereo library & Request ‘K’ tx/rx Surround Monitor library & Request ‘a’ tx/rx Automix data & Request (compressed data) ‘N’ tx/rx Plug-in Effect Card Data & Request Type (HEX) tx/rx function 1 (01) tx/rx Edit buffer 2 (02) tx/rx Patch data 3 (03) tx/rx Setup data 4 (04) tx/rx Backup data 16 (10) tx/rx Function (recall, store, title, clear) 17 (11) rx Function (pair, copy) 18 (12) rx Function (effect) 19 (13) tx/rx Sort table 20 (14) tx/rx Function (attribute, link) 32 (20) rx Key remote 33 (21) tx/rx Remote meter 34 (22) tx/rx Remote time counter 35 (23) tx/rx Automix status * ‘tx’ indicates that the data can be transmitted from the DM1000, and ‘rx’ indicates that the data can be received by the DM1000. 2. Format Details 2.1 NOTE OFF (8n) Reception If [OTHER ECHO] is ON, these message are echoed from MIDI OUT. If the [Rx CH] matches, these messages are received and used to control effects. STATUS 1000nnnn 8n Note off message DATA 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(ignored) 2.2 NOTE ON (9n) Reception If [OTHER ECHO] is ON, these messages are echoed from MIDI OUT. If the [Rx CH] matches, these messages are received and used to control effects. STATUS 1001nnnn 9n Note on message DATA 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(1-127:on, 0:off) 2.3 CONTROL CHANGE (Bn) Reception If [Control Change ECHO] is ON, these messages are echoed from MIDI OUT. If [TABLE] is selected, these message are received if [Control Change Rx] is ON, and will control parameters according to the [Control assign table] settings. The parameters that can be set are defined in the Control Change Assign Parameter List. If [NRPN] is selected, these messages are received if [Control Change Rx] is ON and the [Rx CH] matches, and will control the parameter that is specified by the four messages NRPN control number (62h, 63h) and Data Entry control number (06h, 26h). Parameter settings are defined in the Control Change Assign Parameter List. DM1000 Version 2—Bedienungsanleitung MIDI-Datenformat 367 Transmission If [TABLE] is selected, operating a parameter specified in the [Control assign table] will cause these messages to be transmitted if [Control Change Tx] is ON. The parameters that can be specified are defined in the Control Change Assign Parameter List. If [NRPN] is selected, operating a specified parameter will cause data to be transmitted on the [Tx CH] if [Control Change Tx] is ON, using the four messages NRPN control number (62h, 63h) and Data Entry control number (06h, 26h). Parameter settings are defined in the Control Change Assign Parameter List. This data cannot be transmitted via control change to Studio Manager since there is no guarantee that the contents of the tables will match. (Parameter Change messages will always be used.) If [TABLE] is selected STATUS 1011nnnn Bn Control change DATA 0nnnnnnn...

Other models in this manual:
Musical Instruments - DM1000VCM (7.8 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category