|
manual abstract
To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SOFT CYCLE FOOD TEMPERATURE 40 °F 40 Blinks g. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SOFT CYCLE HOLDING LOW TEMP. 35 °F 35 Blinks h. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SOFT CYCLE HOLDING HIGH TEMP. 42 °F 42 Blinks The display will show: PARAM. PROGRAMMING AUTOMATIC SOFT CYCLE PROGRAMMING COMPLETE 19 AP120BC1000-3/ AP120BCF1300-3 Manual AUTOMATIC HARD CYCLE PARAMETERS PROGRAMMING After about 2 seconds the display will automatically change to: The LED for "A" will be "ON". The LED'S for cycles will be blinking. i. Press the button. The LED for "HARD" will be steady "ON". PARAM. PROGRAMMING AUTOMATIC MODE CHOOSE PROGRAMMING CYCLE j. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE LOW AIR TEMP PART 1 0 °F * 0 Blinks * 0o F for shock freezers (AP120BCF1300-3) 10o F for blast chillers (AP120BC1000-3) k. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE HIGH AIR TEMP PART 1 10 °F ** 10 Blinks ** 10o F for shock freezers (AP120BCF1300-3) 20o F for blast chillers (AP120BC1000-3) l. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE BREAKING TEMP 60 °F 60 Blinks m. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE LOW AIR TEMP PART 2 28 °F 28 Blinks n. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE HIGH AIR TEMP PART 2 35 °F 35 Blinks o. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE HARD FOOD TEMP. 40 °F 40 Blinks p. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC HARD CYCLE HOLDING LOW TEMP. 35 °F 35 Blinks 20 AP120BC1000-3/ AP120BCF1300-3 Manual PARAM. PROGRAMMING q. To change the temperature, press or AUTOMATIC HARD CYCLE HOLDING HIGH TEMP. 42 °F then press . 42 Blinks PARAM. PROGRAMMING The display will show: AUTOMATIC HARD CYCLE PROGRAMMING COMPLETE AUTOMATIC SHOCK CYCLE PARAMETERS PROGRAMMING After about 2 seconds the display will automatically change to: The LED for "A" will be "ON". The LED'S for cycles will be blinking. r. Press the button (for shock freezers only). The LED for "SHOCK" will be steady "ON". PARAM. PROGRAMMING AUTOMATIC MODE CHOOSE PROGRAMMING CYCLE s. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SHOCK CYCLE LOW AIR TEMPERATURE -25 °F -25 Blinks t. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SHOCK CYCLE HIGH AIR TEMPERATURE -15 °F -15 Blinks u. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SHOCK CYCLE FOOD TEMPERATURE 0 °F 0 Blinks v. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SHOCK CYCLE HOLDING LOW TEMP -4 °F -4 Blinks w. To change the temperature, press or then press . PARAM. PROGRAMMING AUTOMATIC SHOCK CYCLE HOLDING HIGH TEMP 3 °F 3 Blinks The display will show: PARAM. PROGRAMMING AUTO SHOCK CYCLE PROGRAMMING COMPLETE 21 AP120BC1000-3/ AP120BCF1300-3 Manual UV LIGHT CYCLE PARAMETERS PROGRAMMING After about 2 seconds the display will automatically change to: The LED for "A" will be "ON". The LED'S for cycles will be blinking. x. Press the button. The LED for "UV LIGHT" will be steady "ON". PARAM. PROGRAMMING AUTOMATIC MODE CHOOSE PROGRAMMING CYCLE y. To change the time, press or then press . 00:30 Blinks The display will show: PARAM. PROGRAMMING UV CYCLE PROGRAMMING COMPLETE PARAM. PROGRAMMING UV CYCLE CYCLE TIME H 00:30 MIN DEFROST CYCLE PARAMETERS PROGRAMMING After about 2 seconds the display will automatically change to: The LED for "A" will be "ON". The LED'S for cycles will be blinking. z. Press the button. The LED for "DEFROST" will be steady "ON". PARAM. PROGRAMMING AUTOMATIC MODE CHOOSE PROGRAMMING CYCLE The defrost type must be left AIR FLOW. aa. Press . AIR FLOW Blinks PARAM. PROGRAMMING DEFROST CYCLE CHOOSE TYPE AIR FLOW 15 Blinks PARAM. PROGRAMMING DEFROST CYCLE MANUAL DEFROST TIME 15 MIN bb. To change the time, press or then press . NO Blinks PARAM. PROGRAMMING DEFROST CYCLE AUTOMATIC DEFROST NO cc. Press or to change to NO then press . PARAM. PROGRAMMING DEFROST CYCLE PROGRAMMING COMPLETE The display will show: NOTE: The defrost is done by running the evaporator fan for 15 minutes with the door open. 22 AP120BC1000-3/ AP120BCF1300-3 Manual HEATED PROBE CYCLE PARAMETERS PROGRAMMING After about 2 seconds the display will automatically change to: The LED for "A" will be "ON". The LED'S for cycles will be blinking. dd. Press the button. The LED for "HEATED PROBE" will be steady "ON". PARAM. PROGRAMMING AUTOMATIC MODE CHOOSE PROGRAMMING CYCLE or 30 Blinks PARAM. PROGRAMMING HEATED PROBE CYCLE HEATING TEMPERATURE 30 °F ee. To change the temperature, press then press . 05 Blinks PARAM. PROGRAMMING HEATED PROBE CYCLE HEATING TIM...
Other models in this manual:Freezers - HURRICHILL AP120BC1000-3 (2.39 mb)