|
manual abstract
Transmission [k][t][ ][Set ID][ ][Data][Cr] Data Min : 00H ~ Max : 64H (Hexadecimal code) • Refer to ‘Real data mapping’ page A7. Acknowledgement [t][ ][Set ID][ ][OK][Data][x] Data Min : 00H ~ Max : 64H * Balance : L50 ~ R50 15. Color Temperature (Command : u) To adjust the screen color temperature. Transmission [k][u][ ][Set ID][ ][Data][Cr] Data 0 : Normal 1 : Cool 2 : Warm 3 : User Acknowledgement [u][ ][Set ID][ ][OK][Data][x] Data 0 : Normal 1 : Cool 2 : Warm 3 : User A10 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 16. Abnomal state (Command : z) Abnormal State : Used to Read the power off status when Stand-by mode. Transmission [k][z][ ][Set ID][ ][Data][Cr] Data FF : Read 0 : Normal (Power on and signal exist) 1: No signal (Power on) 2 : Turn the monitor off by remote control 3 : Turn the monitor off by sleep time function 4 : Turn the monitor off by RS-232C function 6 : AC down 8 : Turn the monitor off by off time function 9 : Turn the monitor off by auto off function Acknowledgement [z][ ][Set ID][ ][OK][Data][x] 17. ISM mode(Command: j p) Used to select the afterimage preventing function. Transmission [j][p][ ][Set ID][ ][Data][Cr] Data 1 : Inversion 2 : Orbiter 4 : White Wash 8 : Normal Acknowledgement [p][ ][Set ID][ ][OK][Data][x] A11 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 18. Auto Configure(Command: j u) To adjust picture position and minimize image shaking automatically. it works only in RGB(PC) mode. Transmission [j][u][ ][Set ID][ ][Data][Cr] Data 1 : To set Acknowledgement [u][ ][Set ID][ ][OK][Data][x] 19. Key(Command : m c) To send IR remote key code. Transmission [m][c][ ][Set ID][ ][Data][Cr] Data Key code : Refer to page A18. Acknowledgement [c][ ][Set ID][ ][OK][Data][x] A12 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 20. Tile Mode(Command : d d) Change a Tile Mode. Transmission [d][d][][Set ID][][Data][x] Data Description 00 Tile mode is off. 12 1 x 2 mode(column x row) 13 1 x 3 mode 14 1 x 4 mode ... ... 44 4 x 4 mode * The data can not be set to 0X or X0 except 00. Acknowledgement [d][][00][][OK/NG][Data][x] A13 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 21. Tile H Size(Command : d g) To set the Horizontal size. Transmission [d][g][][Set ID][][Data][x] Data Min : 00H ~ Max : 64H Acknowledgement [g][][Set ID][][OK/NG][Data][x] 22. Tile V Size(Command : d h) To set the Vertical size. Transmission [d][h][][Set ID][][Data][x] Data Min : 00H ~ Max : 64H Acknowledgement [h][][Set ID][][OK/NG][Data][x] A14 Controlling the Multiple Product RS-232C Transmission / Receiving Protocol 23. Tile ID Set(Command : d i) To assign the Tile ID for Tiling function . Transmission [d][i][][Set ID][][Data][x] Data Min : 00H ~ Max : 10H (Hexadecimal code) Acknowledgement [i][][Set ID][][OK/NG][Data][x] 24. Elapsed time return(Command : d l) To read the elapsed time. Transmission [d][l][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [l][][Set ID][][OK/NG][Data][x] * The data means used hours. (Hexadecimal code) A15 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 25. Temperature value (Command : d n) To read the inside temperature value. Transmission [d][n][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [n][][Set ID][][OK/NG][Data][x] * The data is 1 byte long in Hexadecimal. 26. Lamp fault Check(Command : d p) To check lamp fault. Transmission [d][p][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [p][][Set ID][][OK/NG][Data][x] Data 0 : Lamp Fault 1: Lamp OK A16 RS-232C IR Codes How to connect Remote Control IR Code Lead Low Connect your wired remote control to Remote Control port on the Product. Output waveform single pulse, modulated with 37.917KHz signal at 455KHz Carrier frequency FCAR = 1/Tc = fosc/12 Duty ratio = T1/Tc = 1/3 T1 Tc Configuration of frame • 1st frame code custom code High custom code Data code Data code C0 C1 C2 C3 C4 C5 C6 C7 C0 C1 C2 C3 C4 C5 C6 C7 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 • Repeat frame TfRepeat code Lead code 9ms 4.5ms Repeat code 2.25ms 9ms 0.55ms Bit description • Bit "0" • Bit "1" 0.56ms 1.12ms 0.56ms 2.24ms Frame interval : Tf • The waveform is transmitted as long as a key is depressed. Tf Tf Tf=108ms@455KHz A17 RS-232C IR Codes Code(Hexa) Function Note 00 R/C Button 01 R/C Button 02 VOL( ) R/C Button 03 VOL( ) R/C Button 08 POWER ON/OFF PR/C Button (Power On/Off) C4 POWER ON Discrete IR Code(Only Power On) C5 POWER OFF Discrete IR Code(Only Power On) 09 MUTE R/C Button 98 AV R/C Button 0B INPUT R/C Button 0E SLEEP R/C Button 43 MENU R/C Button 5B EXIT R/C Button 6E PSM R/C Button 44 SET R/C Button 10 Number Key 0 R/C Button 11 Number Key 1 R/C Button 12 Number Key 2 R/C Button 13 Number Key 3 R/C Button 14 Number Key 4 R/C Button 15 Number Key 5 R/C Button 16 Number Key 6 R/C Button 17 Number Key 7 R/C Button...
Other models in this manual:Displays - M3201C-BA (4.19 mb)
Displays - M3201C-BAF (4.19 mb)
Displays - M3201C-SA (4.19 mb)
Displays - M3701C-BA (4.19 mb)