Login:
Votes - , Average rating: ( )

User manual Nilfisk-Advance America, model HSC 585

Manafacture: Nilfisk-Advance America
File size: 543.86 kb
File name: b3fcf084-9c43-4e47-8ebc-2a84456e0ef1.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


WARNING! To reduce the risk of fire, electric shock, or injury: • Do not leave the machine unattended when it is plugged-in. Unplug the unit from the power outlet when not in use. • Unplug the machine from the power outlet before cleaning or servicing. • Turn off all controls before unplugging. • To avoid electric shock, do not expose to rain or snow. Store and use indoors. • Wear hearing protection if desired. The measured sound level of the HSC585 is 75 dB(A) • Do not allow to be used as a toy. Close attention is necessary when used near children. • Use only as described in this manual. Use only the manufacturer’s recommended attachments. • Inspect the power cord regularly for damage, such as cracking, ageing, or damaged insulation. Do not use with damaged cord or plug. If the cord needs to be replaced, take the machine to an authorized Nilfisk • If the cord or prongs become damaged have it replaced by an authorized Nilfisk service technician or partner. • Use a defoamer any time you get foam in the recovery tank, to prevent motor damage. • If foam or liquid comes out of the vacuum motor or exhaust, turn the machine off immediately. • If the machine is not working as it should, has been dropped, damaged, left outdoors or flooded with water, return it to a service center. • Do not pull the machine by the cord, do not use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the machine over the cord. Keep the cord away from heated surfaces.To unplug, grasp the plug, not the cord. • Do not handle the plug, the cord, or the machine with wet hands. • Extension cords must be 12/3 and no longer than 50 feet. Replace the cord or unplug immediately if the ground prong becomes damaged. • Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any health endangering dusts. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present. • Use extra care when cleaning on stairs. • Connect to a properly grounded outlet only. • Liquid pumped out could be dangerous because of temperature, pressure, or chemical content. • Do not let the pump run dry. If you run out of water, turn the machine off and refill. INSPECTION: Carefully unpack and inspect your HSC 585-MULTI for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box or to the machine or parts. CLEANING SOLUTIONS: Select a proper pre-spray for the surface to be cleaned, and apply the pre-spray. Use a neutral pH rinse or detergent (6 to 9 pH) in the HSC 585 to prevent premature wear of the pump, seals and other components. Powdered chemicals are not recommended. MAINTENANCE: For optimum performance, flush the machine with clear water at the end of each working day. Once a month, minimum, run a flushing compound through the machine to break up any mineral or chemical build-up that may have formed in the lines, the pumps, or the heater. The vacuum motor, pump motor, and the pump do not require any scheduled maintenance; however, the vacuum motors may require replacement brushes after 1000 - 1500 hours, and the high pressure pump and unloader valve may require rebuild kits after 500 -1000 hours (refer to machine part list for numbers). Clean the body with an all purpose detergent, and protect it with an automobile interior polish. Lubricate the wheels, castors, and quick disconnects with an all- purpose silicone spray. NOTE: to remove the complete reel with hoses from the machine, pull the vacuum hose loose from the hose barb on the front of the tank, and push the short piece of vacuum hose into the center of the hose spool. Disconnect the solution hose quick coupling. Grasp the spool from either side, and lift it off the machine. NOTE: before servicing any component in the base cabinet, remove the hoses and spool before opening the tanks. Record the serial number and model of your new extractor here: Model: HSC 585-Multi_ Serial Number: __________________ Purchase Date:_____________ Write the name and phone number of your distributor: 11600205211REVA -3 O I I I O O I I SWITCH PLATE 5 HIGH PRESSURE PUMP LIGHT (NO HEAT) DUMP PUMP ON/OFF SWITCH PUMP/HEAT SELECTOR SWITCH 100 PSI PUMP ON/OFF SWITCH 3 VACUUM ON/OFF SWITCH 2 4 HEAT SELECTED LIGHT KNOW YOUR MACHINE HSC 585 MULTI Switches 85 Bar Quick Disconnect Hoses Vacuum Hose Connection Base Compartment Vac Tank Latch 7 Bar Quick Disconnect Solution Tank Wheel Drain Hose Cap Wand Holder Vacumm Tank Lid Castor Pressure with Brake Gauge Wheel Power Prime Pedal Garden Hose Connector Drain Hose Auto Dump Pump Power Cord REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE OPERATION CAUTION: Neve...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category