Login:
Votes - 3, Average rating: 3.7 ( )

User manual Graco Inc., model Hydra-Clean 1020E

Manafacture: Graco Inc.
File size: 799.99 kb
File name: 26f7cc95-88c3-4340-9ac3-a8b90cffb86a.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


NEVER put hand or fingers over the spray tip. NEVER try toStop or deflect leakswith your hand or body. MEDlCAL ~REA~~E~T If an a to your get fluid ears enetrate skin, E&Effi:QG&Y MEDU8AWa.CARE AB ONCG. DO NOT PREAU ASA SUMRE CMU. Tell the doctor exactly what fluid was injected. For treatmentinstructionshaveourdoctorcallthe ~A~UO~A~ POISON CdUEBa NETWORK (412) 689-6669 AVOOD C~ RUPTURE~~ Even after you shut off the electric motor, there is high pressure in the pump, hose and gun until you relieve it by triggering the gun. So before removing the spray tip or servicing the unit,always shut offthe unit and trigger the gun to release pressure. Be surethatall accessory itemsandsystem components will withstand the pressuredeveloped, NEVER exceed the pressure rating of any component in system. NEVER alter or modify equipment-your personal safety, as well as thefunction of 'the equipment, is at stake. Beforeeach use, checkhose for weak, worn or damaged conditions caused by traffic, sharp corners, pinchingorkinking.Tightenallfluidconnections 'securelybeforeeach use. Replace any damaged hose. Do notusechemicalsoragentswhicharenot compatible with Buna-N.Viton, PVC, or neoprene cover of hose. Do not leave a pressurizedunit unattended. Shutoff the unit and relieve pressure before leaving. FURE Do not spray flammable liquids. Do not operate the unit wherecombustiblefumes or dust maybe present. GENERAL NEVER run the unit with the belt guard removed. O~~~~ Keep clear of moving parts when the unit is running. Observedetergent-manufacturer'ssafety precautions. Avoid getting detergent or other liquids in your eyes. Follow the directions on the container regardingcontact with eyes.nose, and.skin, breathing fumes,etc. Always wear full goggles to protect your eyes from the spray as asas any debris well dislodged by the 'spray. If necessary, wear gloves or other protective clothing. If. antidotes or treatment are recommended, be prepared to use them. Don't spray toxic chemicals such as insecticide or weed killer. 2-801-765 INSTALLATION CHECK FOR DAMAGE Check unit for any damage that may have occurred in shipping. Any damage shouldbenotedandthe carrier notified immediately. ELECTRICAL SERVICE The 1020E model comeswith an electric starter box which is notattachedtothe unit. It is up to the installertowirethemotortothestarterandthe starter to the power source. The electrical service required for the 1020Eis 230V / 6Ocycle / 50Amp / 3 phase. An optional 460V/60 cycle / 25 Amp / 3 phase service may be used with special instructions from manufacturer. Refer to instrucfion manual for the wiring diagram page 4. Be sure that all wiring is properly grounded ..-. andaccordingtoalllocalandnationalelectrical ii, ..*. .. ' :'>, codes. ,.. ,. .. ,. .'i INSTALL SPRAY GUN CONNECT TO WATER SUPPLY Refer to Parts Drawing on page 9. connection to water supply. Do not exceed16O0F(7O0C)watertemperaturetothe pump in a direct supply system. Attach lidto tank by drilling four holes use intank and screws, bolts and washers provided. Connectahosewithatleast3/4in.(ISmm)l.D.frOm your water supply to the 3/4 in. garden hose fitting on the water tank. on Connect tank and pump with 3/4 in. I.D. hose and clamps provided with the unit. Place one end of hose hose barb at on bottom of water tank.Place the other end of hose on hose barb at pump inlet. Clamp each end with,hose clamp. Pump water be asclose together as the pin fitting at the end of the hose into the quick possible. A maximum distance of 5 ft. is recomm- coupler on the gun. mended. 801-765 3 Connect the spray hose to the spray gun by inserting module and tankshould WIRING DIAGRAM CAUTION Unit mustbe properlywired to230V/ 60cycle / 50 Amp (three phase) current. MOTOR JUNCTION BOX I I If the optional 460V / 60 cycle / 25 Amp (three phase) current is desired, contact the manufacturer for further instructions. 4 801-765 OPERATION AND STARTUP CARE SHUTDOWN Before'starting, be sure to read the safety warnings and installation instructions. Check oil level in pump Turn on the water supply. water supply is completely turned on and that the water tank is full before operating. Inspect all connectionsforany leaks. Tighten if necessary. Trigger the gun to release any back-pressure. WARNUNG DO NOT wire or tie the gun trigger into the open or triggered position. Push starter switch to ON position. CLEANING The 1020E comes with anupstreamchemical injector system. See photo on page 3. When using the chemical injector insert plasticchemical linewith filter into chemical container. Close large gate valve at water tank outlet until valve bottoms out against factory installed sleeve. Open needle valve, directly connected to the gate valve. Theneedlevalvemaybe used to adjust chemical flow. If chemical does not come up chemical hose, check chemical filter on the end of hose. Check the distance youwill need to hold spray nozzle from surface by test.spraying on a scrap of similar material. For soft surfaces, suchas wood, hold n...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category